Badger Meter FC-5000 BTU Monitor Two frequency outputs Panel

FC5-BM-P1-FC6AP
Contact us for a price
In stock
Delivery
Payment options
Our advantages
  • — 12 months warranty
  • — SMS notification
  • — Return and exchange
  • — Different payment methods
  • — Best price
Column filling
Sort by Price Sort by Availability Sort by CODE Sort by Mounting Sort by Scaled Outputs
$29640
In stock
+
FC5-BM-P1-AC6AP
Mounting:
Panel
Scaled Outputs:
Two analog outputs
$81380
In stock
+
FC5-BM-P1-AC6AW
Mounting:
Wall, NEMA 4X (IP67) rated enclosure
Scaled Outputs:
Two analog outputs
Contact us for a price
In stock
FC5-BM-P1-FC6AP
Mounting:
Panel
Scaled Outputs:
Two frequency outputs
$51740
In stock
+
FC5-BM-P1-FC6AW
Mounting:
Wall, NEMA 4X (IP67) rated enclosure
Scaled Outputs:
Two frequency outputs

Features

  • 100 µs/3.5 ms min pulse (high/low speed)
  • 1 pulse and 2 temperature sensor inputs
  • 2 form C relay outputs
  • 6 programmable digital inputs/outputs
  • 0.3 to 10 kHz flow input
  • 0 to 30V digital input
  • ±0.01% uncertainty for flow calculations
  • EIA-485(RS-485), Modbus, BACnet, and USB
  • 128 × 64 pixel LCD display
  • Low voltage AC/DC power

The Badger Meter FC-5000 BTU Monitor provides accurate measurement of power/energy consumption used in closed-loop, hydronic thermal transfer systems, typically found in HVAC sub-metering applications. The FC-5000 products are microprocessor-driven devices designed for flow monitoring, while the BTU Monitor expands device capabilities by integrating inputs for fluid temperature data. Instantaneous rate and total energy consumption is achieved, simultaneously, while conforming to EN 1434 calculation standards.

Input signal, in the form of sine waves or pulses from open collector transistors or dry contact closures, can be scaled to any unit of measure for totalization and instantaneous rate-of-flow indication. Energy rate and flow totals are examples of parameters that can be viewed on the panel display or through communications protocols such as BACnet or Modbus. Two temperature sensor inputs can be configured to read RTDs or thermistors and are fully customizable to adapt to application needs. When used in conjunction with fluid flow, hydronic energy rates and total usage are achieved.

Additionally, dedicated analog or frequency output channels provide scaled outputs that are assignable to parameters such as energy rate, total and temperature. A user defined damping function can be applied for improved stability of the flow readings.

c-5000-datasheet (fc-5000-datasheet.pdf, 918 Kb) [Download]

c-5000-manual (fc-5000-manual.pdf, 4,074 Kb) [Download]

Flow-Application-Information-Form (Flow-Application-Information-Form.pdf, 268 Kb) [Download]

You may be interested
  • Most Popular
  • On Sale
  • Recently Viewed
 
Fast and high quality delivery

Our company makes delivery all over the country

Quality assurance and service

We offer only those goods, in which quality we are sure

Returns within 30 days

You have 30 days to test your purchase