PhyMetrix PPBa Benchtop Dew Point Analyzer Not included Included Not included Not included

PPBa-I
7,05859
In stock
+
Add to wish list
Delivery
Payment options
Our advantages
  • — 12 months warranty
  • — SMS notification
  • — Return and exchange
  • — Different payment methods
  • — Best price
Column filling
Sort by Price Sort by Availability Sort by CODE Sort by Analog Output Sort by Pressure Sensor Sort by Intrinsically Safe ATEX Sort by Vacuum Pump
10,05469
In stock
+
PPBa-P-I-A-V
Analog Output:
4/20 mA with HART option
Pressure Sensor:
0 to 150 psia with automatic pressure correction
Intrinsically Safe ATEX:
Included
Vacuum Pump:
Built-in, includes high capacity internal battery and external charger
8,42969
In stock
+
PPBa-P-I-A
Analog Output:
4/20 mA with HART option
Pressure Sensor:
0 to 150 psia with automatic pressure correction
Intrinsically Safe ATEX:
Included
Vacuum Pump:
Not included
9,14063
In stock
+
PPBa-P-I-V
Analog Output:
Not included
Pressure Sensor:
0 to 150 psia with automatic pressure correction
Intrinsically Safe ATEX:
Included
Vacuum Pump:
Built-in, includes high capacity internal battery and external charger
7,51563
In stock
+
PPBa-P-I
Analog Output:
Not included
Pressure Sensor:
0 to 150 psia with automatic pressure correction
Intrinsically Safe ATEX:
Included
Vacuum Pump:
Not included
9,14063
In stock
+
PPBa-P-A-V
Analog Output:
4/20 mA with HART option
Pressure Sensor:
0 to 150 psia with automatic pressure correction
Intrinsically Safe ATEX:
Not included
Vacuum Pump:
Built-in, includes high capacity internal battery and external charger
7,51563
In stock
+
PPBa-P-A
Analog Output:
4/20 mA with HART option
Pressure Sensor:
0 to 150 psia with automatic pressure correction
Intrinsically Safe ATEX:
Not included
Vacuum Pump:
Not included
8,22656
In stock
+
PPBa-P-V
Analog Output:
Not included
Pressure Sensor:
0 to 150 psia with automatic pressure correction
Intrinsically Safe ATEX:
Not included
Vacuum Pump:
Built-in, includes high capacity internal battery and external charger
6,60156
In stock
+
PPBa-P
Analog Output:
Not included
Pressure Sensor:
0 to 150 psia with automatic pressure correction
Intrinsically Safe ATEX:
Not included
Vacuum Pump:
Not included
9,59766
In stock
+
PPBa-I-A-V
Analog Output:
4/20 mA with HART option
Pressure Sensor:
Not included
Intrinsically Safe ATEX:
Included
Vacuum Pump:
Built-in, includes high capacity internal battery and external charger
7,97266
In stock
+
PPBa-I-A
Analog Output:
4/20 mA with HART option
Pressure Sensor:
Not included
Intrinsically Safe ATEX:
Included
Vacuum Pump:
Not included
8,68359
In stock
+
PPBa-I-V
Analog Output:
Not included
Pressure Sensor:
Not included
Intrinsically Safe ATEX:
Included
Vacuum Pump:
Built-in, includes high capacity internal battery and external charger
7,05859
In stock
+
PPBa-I
Analog Output:
Not included
Pressure Sensor:
Not included
Intrinsically Safe ATEX:
Included
Vacuum Pump:
Not included
8,68359
In stock
+
PPBa-A-V
Analog Output:
4/20 mA with HART option
Pressure Sensor:
Not included
Intrinsically Safe ATEX:
Not included
Vacuum Pump:
Built-in, includes high capacity internal battery and external charger
7,05859
In stock
+
PPBa-A
Analog Output:
4/20 mA with HART option
Pressure Sensor:
Not included
Intrinsically Safe ATEX:
Not included
Vacuum Pump:
Not included
7,76953
In stock
+
PPBa-V
Analog Output:
Not included
Pressure Sensor:
Not included
Intrinsically Safe ATEX:
Not included
Vacuum Pump:
Built-in, includes high capacity internal battery and external charger
6,14453
In stock
+
PPBa
Analog Output:
Not included
Pressure Sensor:
Not included
Intrinsically Safe ATEX:
Not included
Vacuum Pump:
Not included

Features

  • -110°C to +20°C dewpoint Sensor range
  • ±3.6˚F (2˚C) accuracy
  • 1.5˚F (0.8˚C) repeatability
  • 95% of step change in 3 min. response time
  • >1 LPM sample flow
  • -40 to 158˚F (-40 to 70˚C) temp range
  • 316 Stainless Steel and PTFE wetted parts
  • 1/8” Swagelok® compression fittings
  • Aluminum enclosure
  • On-screen histogram/trend graph
  • Built-in temperature compensation
  • Integral Sensor desiccant storage chamber
  • USB data interface, also charges battery
  • Battery backed clock calendar
  • Programmable data logging
  • Continuous status/diagnostics display
  • Built-in metering valve and flow meter

The PhyMetrix PPBa Benchtop Dew Point Analyzer has a continuous status and diagnostic display, with and on-screen histogram and trend graph. Its USB interface also charges the battery. The PPBa has an optional pressure sensor with automatic dew point correction and an optional built-in vacuum pump for sub-atmospheric samples.

PPBa-datasheet (PPBa-datasheet.pdf, 539 Kb) [Download]

Portable-Users-Manual-PPMa-PPBa (Portable-Users-Manual-PPMa-PPBa.pdf, 2,452 Kb) [Download]

PhyMetrix-Moisture-Analyzer-Application-Worksheet_nocontactinfo (PhyMetrix-Moisture-Analyzer-Application-Worksheet_nocontactinfo.pdf, 159 Kb) [Download]