Honeywell RAEGuard 2 PID 0.1 to 1000 ppm isobutylene equivalent ATEX/IECEx

H-D03-0005-000
$8,12760
In stock
+
Add to wish list
Delivery
Payment options
Our advantages
  • — 12 months warranty
  • — SMS notification
  • — Return and exchange
  • — Different payment methods
  • — Best price
Column filling
Sort by Price Sort by Availability Sort by CODE Sort by Range Sort by Approval
$10,15820
In stock
+
H-D03-0004-000
Range:
0.01 to 100 ppm isobutylene equivalent
Approval:
ATEX/IECEx
$9,53290
In stock
+
H-D03-0009-000
Range:
0.01 to 100 ppm isobutylene equivalent
Approval:
UL
$8,12760
In stock
+
H-D03-0005-000
Range:
0.1 to 1000 ppm isobutylene equivalent
Approval:
ATEX/IECEx
$7,62580
In stock
+
H-D03-0010-000
Range:
0.1 to 1000 ppm isobutylene equivalent
Approval:
UL
$4,06510
In stock
+
H-D03-0008-000
Range:
1 to 1000 ppm isobutylene equivalent (No Alarms)
Approval:
ATEX/IECEx
$4,34200
In stock
+
H-D03-0012-000
Range:
1 to 1000 ppm isobutylene equivalent (No Alarms)
Approval:
UL

Features

  • Digital Smart Sensor Technology
  • Detection range options:
    • 0.01 to 100ppm, 0.1 to 1000ppm, or 1 to 1000ppm
  • Operates in flow-through mode
  • Three wires, supports 4-20mA analog output
  • RS-485 digital communication in ModBus protocol
  • Explosion-proof stainless-steel enclosure
    • For hazardous environment applications
    • Adjust parameters without opening housing
  • Matrix LCD of 128 x 64 supports graphic display
  • LED alarms when High or Low alarm point is reached
  • Operation at 10 to 28 VDC
  • Three dry contacts
    • (<30Vdc, 2A) normally open (or normally closed)
    • High and Low alarm
    • Fault alarm

The Honeywell RAEGuard 2 PID is a fixed photoionization detector (PID) that measures a broad range of volatile organic compounds (VOCs). The RAEGuard 2 PID operates on 10 to 28 VDC and provides an analog 4-20mA, three-wire signal output and RS-485 Modbus digital signal output.

The RAEGuard 2 PID uses an intelligent processing platform and digital sensor technology that supports multiple ranges and resolutions and is capable of environmental self-adaptation. Calibration and maintenance have been greatly simplified as the digital PID module can be easily removed in hazardous locations for calibration or maintenance.

The RAEGuard 2 PID has a graphic display and local sound alarm and LED light status indicator. In addition, Low, High, and Fault relays can be configured to trigger external alarms or process controls. A magnetic key interface enables the detector to be calibrated and operational parameters adjusted with the explosion-proof enclosure in place.

Some key applications for the RAEGuard 2 PID along with the PIDs involved include:

  • Benzene in refinery analyzer shelters
  • Ammonia in industry
  • Vinyl Chloride in chemical manufacturing
  • Toluene or Ammonia in semi-conductor plants
  • Chlorine Dioxide, Hydrogen Peroxide, Ozone in pulp and paper
  • Solvent and chemicals storage
  • Phenol and DME in pharmaceutical
  • Toluene in printing
  • Air quality
  • Methyl Ethyl Ketone in paint spray booths
  • Heat transfer fluids
  • Acetone, Xylene, Phenol in medical, pathology, histology lab

RAEGuard2PID-datasheet (RAEGuard2PID-datasheet.pdf, 704 Kb) [Download]

Honeywell-RAEGuard-2-PID-Manual (Honeywell-RAEGuard-2-PID-Manual.pdf, 3,421 Kb) [Download]

RAE-Instrument-Response (RAE-Instrument-Response.pdf, 849 Kb) [Download]

Honeywell-RAEGuard-Installation-Guide (Honeywell-RAEGuard-Installation-Guide.pdf, 180 Kb) [Download]

Honeywell-Gas-Detection-Bump-Test-and-Calibration-Frequency (Honeywell-Gas-Detection-Bump-Test-and-Calibration-Frequency.pdf, 70 Kb) [Download]

Honeywell-GasBook (Honeywell-GasBook.pdf, 12,619 Kb) [Download]