Define Instruments TEX-TOTAL Flow Rate Panel Meter 15 to 48VAC / 10 to 72VDC 4 RS232 (RJ11 terminal)

TEX-TOTAL-LV-R4-S2R
£39691
In stock
+
Add to wish list
Delivery
Payment options
Our advantages
  • — 12 months warranty
  • — SMS notification
  • — Return and exchange
  • — Different payment methods
  • — Best price
Column filling
Sort by Price Sort by Availability Sort by CODE Sort by Power Supply Sort by Analog Output Sort by Relay Outputs Sort by Serial Port
£24410
In stock
+
TEX-TOTAL-LV
Power Supply:
15 to 48VAC / 10 to 72VDC
Analog Output:
None
Relay Outputs:
None
Serial Port:
None
£29250
In stock
+
TEX-TOTAL-LV-R2
Power Supply:
15 to 48VAC / 10 to 72VDC
Analog Output:
None
Relay Outputs:
2
Serial Port:
None
£34713
In stock
+
TEX-TOTAL-LV-R2 -A
Power Supply:
15 to 48VAC / 10 to 72VDC
Analog Output:
4 to 20mA / 0 to 10V
Relay Outputs:
2
Serial Port:
None
£41351
In stock
+
TEX-TOTAL-LV-R2 -A-S2R
Power Supply:
15 to 48VAC / 10 to 72VDC
Analog Output:
4 to 20mA / 0 to 10V
Relay Outputs:
2
Serial Port:
RS232 (RJ11 terminal)
£41559
In stock
+
TEX-TOTAL-LV-R2 -A-S4S
Power Supply:
15 to 48VAC / 10 to 72VDC
Analog Output:
4 to 20mA / 0 to 10V
Relay Outputs:
2
Serial Port:
RS485 (screw terminal)
£35888
In stock
+
TEX-TOTAL-LV-R2 -S2R
Power Supply:
15 to 48VAC / 10 to 72VDC
Analog Output:
None
Relay Outputs:
2
Serial Port:
RS232 (RJ11 terminal)
£36096
In stock
+
TEX-TOTAL-LV-R2 -S4S
Power Supply:
15 to 48VAC / 10 to 72VDC
Analog Output:
None
Relay Outputs:
2
Serial Port:
RS485 (screw terminal)
£33053
In stock
+
TEX-TOTAL-LV-R4
Power Supply:
15 to 48VAC / 10 to 72VDC
Analog Output:
None
Relay Outputs:
4
Serial Port:
None
£38516
In stock
+
TEX-TOTAL-LV-R4-A
Power Supply:
15 to 48VAC / 10 to 72VDC
Analog Output:
4 to 20mA / 0 to 10V
Relay Outputs:
4
Serial Port:
None
£45154
In stock
+
TEX-TOTAL-LV-R4-A-S2R
Power Supply:
15 to 48VAC / 10 to 72VDC
Analog Output:
4 to 20mA / 0 to 10V
Relay Outputs:
4
Serial Port:
RS232 (RJ11 terminal)
£45362
In stock
+
TEX-TOTAL-LV-R4-A-S4S
Power Supply:
15 to 48VAC / 10 to 72VDC
Analog Output:
4 to 20mA / 0 to 10V
Relay Outputs:
4
Serial Port:
RS485 (screw terminal)
£39691
In stock
+
TEX-TOTAL-LV-R4-S2R
Power Supply:
15 to 48VAC / 10 to 72VDC
Analog Output:
None
Relay Outputs:
4
Serial Port:
RS232 (RJ11 terminal)
£39899
In stock
+
TEX-TOTAL-LV-R4-S4S
Power Supply:
15 to 48VAC / 10 to 72VDC
Analog Output:
None
Relay Outputs:
4
Serial Port:
RS485 (screw terminal)
£29872
In stock
+
TEX-TOTAL-LV-A
Power Supply:
15 to 48VAC / 10 to 72VDC
Analog Output:
4 to 20mA / 0 to 10V
Relay Outputs:
None
Serial Port:
None
£36511
In stock
+
TEX-TOTAL-LV-A-S2R
Power Supply:
15 to 48VAC / 10 to 72VDC
Analog Output:
4 to 20mA / 0 to 10V
Relay Outputs:
None
Serial Port:
RS232 (RJ11 terminal)
£36718
In stock
+
TEX-TOTAL-LV-A-S4S
Power Supply:
15 to 48VAC / 10 to 72VDC
Analog Output:
4 to 20mA / 0 to 10V
Relay Outputs:
None
Serial Port:
RS485 (screw terminal)
£31048
In stock
+
TEX-TOTAL-LV-S2R
Power Supply:
15 to 48VAC / 10 to 72VDC
Analog Output:
None
Relay Outputs:
None
Serial Port:
RS232 (RJ11 terminal)
£31255
In stock
+
TEX-TOTAL-LV-S4S
Power Supply:
15 to 48VAC / 10 to 72VDC
Analog Output:
None
Relay Outputs:
None
Serial Port:
RS485 (screw terminal)
£24410
In stock
+
TEX-TOTAL-HV
Power Supply:
85 to 265VAC / 95 to 370VDC
Analog Output:
None
Relay Outputs:
None
Serial Port:
None
£29250
In stock
+
TEX-TOTAL-HV-R2
Power Supply:
85 to 265VAC / 95 to 370VDC
Analog Output:
None
Relay Outputs:
2
Serial Port:
None
£34713
In stock
+
TEX-TOTAL-HV-R2 -A
Power Supply:
85 to 265VAC / 95 to 370VDC
Analog Output:
4 to 20mA / 0 to 10V
Relay Outputs:
2
Serial Port:
None
£41351
In stock
+
TEX-TOTAL-HV-R2 -A-S2R
Power Supply:
85 to 265VAC / 95 to 370VDC
Analog Output:
4 to 20mA / 0 to 10V
Relay Outputs:
2
Serial Port:
RS232 (RJ11 terminal)
£41559
In stock
+
TEX-TOTAL-HV-R2 -A-S4S
Power Supply:
85 to 265VAC / 95 to 370VDC
Analog Output:
4 to 20mA / 0 to 10V
Relay Outputs:
2
Serial Port:
RS485 (screw terminal)
£35888
In stock
+
TEX-TOTAL-HV-R2 -S2R
Power Supply:
85 to 265VAC / 95 to 370VDC
Analog Output:
None
Relay Outputs:
2
Serial Port:
RS232 (RJ11 terminal)
£36096
In stock
+
TEX-TOTAL-HV-R2 -S4S
Power Supply:
85 to 265VAC / 95 to 370VDC
Analog Output:
None
Relay Outputs:
2
Serial Port:
RS485 (screw terminal)
£33053
In stock
+
TEX-TOTAL-HV-R4
Power Supply:
85 to 265VAC / 95 to 370VDC
Analog Output:
None
Relay Outputs:
4
Serial Port:
None
£38516
In stock
+
TEX-TOTAL-HV-R4-A
Power Supply:
85 to 265VAC / 95 to 370VDC
Analog Output:
4 to 20mA / 0 to 10V
Relay Outputs:
4
Serial Port:
None
£45154
In stock
+
TEX-TOTAL-HV-R4-A-S2R
Power Supply:
85 to 265VAC / 95 to 370VDC
Analog Output:
4 to 20mA / 0 to 10V
Relay Outputs:
4
Serial Port:
RS232 (RJ11 terminal)
£45362
In stock
+
TEX-TOTAL-HV-R4-A-S4S
Power Supply:
85 to 265VAC / 95 to 370VDC
Analog Output:
4 to 20mA / 0 to 10V
Relay Outputs:
4
Serial Port:
RS485 (screw terminal)
£39691
In stock
+
TEX-TOTAL-HV-R4-S2R
Power Supply:
85 to 265VAC / 95 to 370VDC
Analog Output:
None
Relay Outputs:
4
Serial Port:
RS232 (RJ11 terminal)
£39899
In stock
+
TEX-TOTAL-HV-R4-S4S
Power Supply:
85 to 265VAC / 95 to 370VDC
Analog Output:
None
Relay Outputs:
4
Serial Port:
RS485 (screw terminal)
£29872
In stock
+
TEX-TOTAL-HV-A
Power Supply:
85 to 265VAC / 95 to 370VDC
Analog Output:
4 to 20mA / 0 to 10V
Relay Outputs:
None
Serial Port:
None
£36511
In stock
+
TEX-TOTAL-HV-A-S2R
Power Supply:
85 to 265VAC / 95 to 370VDC
Analog Output:
4 to 20mA / 0 to 10V
Relay Outputs:
None
Serial Port:
RS232 (RJ11 terminal)
£36718
In stock
+
TEX-TOTAL-HV-A-S4S
Power Supply:
85 to 265VAC / 95 to 370VDC
Analog Output:
4 to 20mA / 0 to 10V
Relay Outputs:
None
Serial Port:
RS485 (screw terminal)
£31048
In stock
+
TEX-TOTAL-HV-S2R
Power Supply:
85 to 265VAC / 95 to 370VDC
Analog Output:
None
Relay Outputs:
None
Serial Port:
RS232 (RJ11 terminal)
£31255
In stock
+
TEX-TOTAL-HV-S4S
Power Supply:
85 to 265VAC / 95 to 370VDC
Analog Output:
None
Relay Outputs:
None
Serial Port:
RS485 (screw terminal)

Features

  • 0 or 4 to 20mA input
    • 16-bit resolution
    • 0.05% of reading accuracy
    • 10Hz sampling rate
    • 50ppm/°C typical ambient drift
    • Supplies 24VDC excitation (50mA max)
  • Optional 4 to 20mA or 0 to 10V analog output
  • Optional RS232 or RS485 serial port
  • Available with 2 or 4 relay outputs
  • Front panel programmable
  • Available with low or high voltage power supply
  • IP65 rated dust & splash proof face
  • Security PIN protected
  • CE approved & 5-year guarantee

The Define Instruments TEX-TOTAL flow rate panel meter accepts mA input from a flow meter and displays a total. It is ideal for use in conjunction with a transmitter or sensor with mA output to power a 2/3 wire input loop. It features dual totalizers which are individually programmable for low flow cut-off, and rollover functions. Volumetric pulse with adjustable pulse width is available on Total 2.

The TEX-TOTAL uses input signal averaging to reduce noise and ensure stable measurements. If the change in input exceeds the averaging window value it will not average, ensuring fast response when there are large differences between readings. If your input signal contains large noise spikes you can increase the size of the averaging window to ensure that these are still averaged as well.

The TEX-TOTAL is front panel programmable and easy to scale to suit your desired time and measurement units. You can configure up to 4 setpoints, depending on the number of relays you select. Your settings remain secure with the PIN protection; the input calibration and setpoint functions have independent codes so you can give access to one and not the other.

TEX-TOTAL-Datasheet (TEX-TOTAL-Datasheet.pdf, 99 Kb) [Download]

TEX-TOTAL-manual (TEX-TOTAL-manual.pdf, 390 Kb) [Download]

You may be interested
  • Most Popular
  • On Sale
  • Recently Viewed
 
Fast and high quality delivery

Our company makes delivery all over the country

Quality assurance and service

We offer only those goods, in which quality we are sure

Returns within 30 days

You have 30 days to test your purchase