VEGA VEGAMET 841 Controller CCOE/KTL/TIIS/NEPSI; Installation Ex free area,intrinsically safe power supply, Zone 0, 1, 2 + Zone 20, 21, 22 not CCOE) With (certificate, as WHG conform limit alarm) M20x1.5 / 5x cable gland PA (ø6-12mm) For tube mounting (ø29-60mm), stainless steel

MET841.TCWSE
$1,48850
In stock
+
Add to wish list
Delivery
Payment options
Our advantages
  • — 12 months warranty
  • — SMS notification
  • — Return and exchange
  • — Different payment methods
  • — Best price
Column filling
Sort by Price Sort by Availability Sort by CODE Sort by Explosion Protection Sort by Approved as Overfill Protection Sort by Cable Entry / Connection Sort by Mounting / Material
$1,53010
In stock
+
MET841.VCW2E
Explosion Protection:
ATEX/c-UL-us; Installation Ex-free area; intrinsically safe supply, Class I Division 1, 2 + Class II,III Division 1, 2
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,46900
In stock
+
MET841.VCW2C
Explosion Protection:
ATEX/c-UL-us; Installation Ex-free area; intrinsically safe supply, Class I Division 1, 2 + Class II,III Division 1, 2
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For wall mounting, plastic
$1,48850
In stock
+
MET841.VCWSE
Explosion Protection:
ATEX/c-UL-us; Installation Ex-free area; intrinsically safe supply, Class I Division 1, 2 + Class II,III Division 1, 2
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,42740
In stock
+
MET841.VCWSC
Explosion Protection:
ATEX/c-UL-us; Installation Ex-free area; intrinsically safe supply, Class I Division 1, 2 + Class II,III Division 1, 2
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For wall mounting, plastic
$1,42220
In stock
+
MET841.VCW1E
Explosion Protection:
ATEX/c-UL-us; Installation Ex-free area; intrinsically safe supply, Class I Division 1, 2 + Class II,III Division 1, 2
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,36110
In stock
+
MET841.VCW1C
Explosion Protection:
ATEX/c-UL-us; Installation Ex-free area; intrinsically safe supply, Class I Division 1, 2 + Class II,III Division 1, 2
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For wall mounting, plastic
$1,47550
In stock
+
MET841.VCX2E
Explosion Protection:
ATEX/c-UL-us; Installation Ex-free area; intrinsically safe supply, Class I Division 1, 2 + Class II,III Division 1, 2
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,41440
In stock
+
MET841.VCX2C
Explosion Protection:
ATEX/c-UL-us; Installation Ex-free area; intrinsically safe supply, Class I Division 1, 2 + Class II,III Division 1, 2
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For wall mounting, plastic
$1,43390
In stock
+
MET841.VCXSE
Explosion Protection:
ATEX/c-UL-us; Installation Ex-free area; intrinsically safe supply, Class I Division 1, 2 + Class II,III Division 1, 2
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,37280
In stock
+
MET841.VCXSC
Explosion Protection:
ATEX/c-UL-us; Installation Ex-free area; intrinsically safe supply, Class I Division 1, 2 + Class II,III Division 1, 2
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For wall mounting, plastic
$1,36760
In stock
+
MET841.VCX1E
Explosion Protection:
ATEX/c-UL-us; Installation Ex-free area; intrinsically safe supply, Class I Division 1, 2 + Class II,III Division 1, 2
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,30650
In stock
+
MET841.VCX1C
Explosion Protection:
ATEX/c-UL-us; Installation Ex-free area; intrinsically safe supply, Class I Division 1, 2 + Class II,III Division 1, 2
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For wall mounting, plastic
$1,61850
In stock
+
MET841.VAW2E
Explosion Protection:
c-UL-us; Installation DIV2, gas; intrinsically safe supply, Zone 0, 1, 2 (Class I Division 1, 2) + Zone 20, 21, 22 (Clas
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,55740
In stock
+
MET841.VAW2C
Explosion Protection:
c-UL-us; Installation DIV2, gas; intrinsically safe supply, Zone 0, 1, 2 (Class I Division 1, 2) + Zone 20, 21, 22 (Clas
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For wall mounting, plastic
$1,57690
In stock
+
MET841.VAWSE
Explosion Protection:
c-UL-us; Installation DIV2, gas; intrinsically safe supply, Zone 0, 1, 2 (Class I Division 1, 2) + Zone 20, 21, 22 (Clas
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,51580
In stock
+
MET841.VAWSC
Explosion Protection:
c-UL-us; Installation DIV2, gas; intrinsically safe supply, Zone 0, 1, 2 (Class I Division 1, 2) + Zone 20, 21, 22 (Clas
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For wall mounting, plastic
$1,51060
In stock
+
MET841.VAW1E
Explosion Protection:
c-UL-us; Installation DIV2, gas; intrinsically safe supply, Zone 0, 1, 2 (Class I Division 1, 2) + Zone 20, 21, 22 (Clas
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,44950
In stock
+
MET841.VAW1C
Explosion Protection:
c-UL-us; Installation DIV2, gas; intrinsically safe supply, Zone 0, 1, 2 (Class I Division 1, 2) + Zone 20, 21, 22 (Clas
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For wall mounting, plastic
$1,56390
In stock
+
MET841.VAX2E
Explosion Protection:
c-UL-us; Installation DIV2, gas; intrinsically safe supply, Zone 0, 1, 2 (Class I Division 1, 2) + Zone 20, 21, 22 (Clas
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,50280
In stock
+
MET841.VAX2C
Explosion Protection:
c-UL-us; Installation DIV2, gas; intrinsically safe supply, Zone 0, 1, 2 (Class I Division 1, 2) + Zone 20, 21, 22 (Clas
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For wall mounting, plastic
$1,52230
In stock
+
MET841.VAXSE
Explosion Protection:
c-UL-us; Installation DIV2, gas; intrinsically safe supply, Zone 0, 1, 2 (Class I Division 1, 2) + Zone 20, 21, 22 (Clas
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,46120
In stock
+
MET841.VAXSC
Explosion Protection:
c-UL-us; Installation DIV2, gas; intrinsically safe supply, Zone 0, 1, 2 (Class I Division 1, 2) + Zone 20, 21, 22 (Clas
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For wall mounting, plastic
$1,45600
In stock
+
MET841.VAX1E
Explosion Protection:
c-UL-us; Installation DIV2, gas; intrinsically safe supply, Zone 0, 1, 2 (Class I Division 1, 2) + Zone 20, 21, 22 (Clas
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,39490
In stock
+
MET841.VAX1C
Explosion Protection:
c-UL-us; Installation DIV2, gas; intrinsically safe supply, Zone 0, 1, 2 (Class I Division 1, 2) + Zone 20, 21, 22 (Clas
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For wall mounting, plastic
$1,53010
In stock
+
MET841.TCW2E
Explosion Protection:
CCOE/KTL/TIIS/NEPSI; Installation Ex free area,intrinsically safe power supply, Zone 0, 1, 2 + Zone 20, 21, 22 not CCOE)
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,46900
In stock
+
MET841.TCW2C
Explosion Protection:
CCOE/KTL/TIIS/NEPSI; Installation Ex free area,intrinsically safe power supply, Zone 0, 1, 2 + Zone 20, 21, 22 not CCOE)
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For wall mounting, plastic
$1,48850
In stock
+
MET841.TCWSE
Explosion Protection:
CCOE/KTL/TIIS/NEPSI; Installation Ex free area,intrinsically safe power supply, Zone 0, 1, 2 + Zone 20, 21, 22 not CCOE)
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,42740
In stock
+
MET841.TCWSC
Explosion Protection:
CCOE/KTL/TIIS/NEPSI; Installation Ex free area,intrinsically safe power supply, Zone 0, 1, 2 + Zone 20, 21, 22 not CCOE)
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For wall mounting, plastic
$1,42220
In stock
+
MET841.TCW1E
Explosion Protection:
CCOE/KTL/TIIS/NEPSI; Installation Ex free area,intrinsically safe power supply, Zone 0, 1, 2 + Zone 20, 21, 22 not CCOE)
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,36110
In stock
+
MET841.TCW1C
Explosion Protection:
CCOE/KTL/TIIS/NEPSI; Installation Ex free area,intrinsically safe power supply, Zone 0, 1, 2 + Zone 20, 21, 22 not CCOE)
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For wall mounting, plastic
$1,47550
In stock
+
MET841.TCX2E
Explosion Protection:
CCOE/KTL/TIIS/NEPSI; Installation Ex free area,intrinsically safe power supply, Zone 0, 1, 2 + Zone 20, 21, 22 not CCOE)
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,41440
In stock
+
MET841.TCX2C
Explosion Protection:
CCOE/KTL/TIIS/NEPSI; Installation Ex free area,intrinsically safe power supply, Zone 0, 1, 2 + Zone 20, 21, 22 not CCOE)
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For wall mounting, plastic
$1,43390
In stock
+
MET841.TCXSE
Explosion Protection:
CCOE/KTL/TIIS/NEPSI; Installation Ex free area,intrinsically safe power supply, Zone 0, 1, 2 + Zone 20, 21, 22 not CCOE)
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,37280
In stock
+
MET841.TCXSC
Explosion Protection:
CCOE/KTL/TIIS/NEPSI; Installation Ex free area,intrinsically safe power supply, Zone 0, 1, 2 + Zone 20, 21, 22 not CCOE)
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For wall mounting, plastic
$1,36760
In stock
+
MET841.TCX1E
Explosion Protection:
CCOE/KTL/TIIS/NEPSI; Installation Ex free area,intrinsically safe power supply, Zone 0, 1, 2 + Zone 20, 21, 22 not CCOE)
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,30650
In stock
+
MET841.TCX1C
Explosion Protection:
CCOE/KTL/TIIS/NEPSI; Installation Ex free area,intrinsically safe power supply, Zone 0, 1, 2 + Zone 20, 21, 22 not CCOE)
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For wall mounting, plastic
$1,53010
In stock
+
MET841.WCW2E
Explosion Protection:
INMETRO/IA; installation Ex-free area; intrinsically safe supply, Zone 0, 1, 2 + Zone 20, 21, 22
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,46900
In stock
+
MET841.WCW2C
Explosion Protection:
INMETRO/IA; installation Ex-free area; intrinsically safe supply, Zone 0, 1, 2 + Zone 20, 21, 22
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For wall mounting, plastic
$1,48850
In stock
+
MET841.WCWSE
Explosion Protection:
INMETRO/IA; installation Ex-free area; intrinsically safe supply, Zone 0, 1, 2 + Zone 20, 21, 22
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,42740
In stock
+
MET841.WCWSC
Explosion Protection:
INMETRO/IA; installation Ex-free area; intrinsically safe supply, Zone 0, 1, 2 + Zone 20, 21, 22
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For wall mounting, plastic
$1,42220
In stock
+
MET841.WCW1E
Explosion Protection:
INMETRO/IA; installation Ex-free area; intrinsically safe supply, Zone 0, 1, 2 + Zone 20, 21, 22
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,36110
In stock
+
MET841.WCW1C
Explosion Protection:
INMETRO/IA; installation Ex-free area; intrinsically safe supply, Zone 0, 1, 2 + Zone 20, 21, 22
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For wall mounting, plastic
$1,47550
In stock
+
MET841.WCX2E
Explosion Protection:
INMETRO/IA; installation Ex-free area; intrinsically safe supply, Zone 0, 1, 2 + Zone 20, 21, 22
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,41440
In stock
+
MET841.WCX2C
Explosion Protection:
INMETRO/IA; installation Ex-free area; intrinsically safe supply, Zone 0, 1, 2 + Zone 20, 21, 22
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For wall mounting, plastic
$1,43390
In stock
+
MET841.WCXSE
Explosion Protection:
INMETRO/IA; installation Ex-free area; intrinsically safe supply, Zone 0, 1, 2 + Zone 20, 21, 22
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,37280
In stock
+
MET841.WCXSC
Explosion Protection:
INMETRO/IA; installation Ex-free area; intrinsically safe supply, Zone 0, 1, 2 + Zone 20, 21, 22
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For wall mounting, plastic
$1,36760
In stock
+
MET841.WCX1E
Explosion Protection:
INMETRO/IA; installation Ex-free area; intrinsically safe supply, Zone 0, 1, 2 + Zone 20, 21, 22
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,30650
In stock
+
MET841.WCX1C
Explosion Protection:
INMETRO/IA; installation Ex-free area; intrinsically safe supply, Zone 0, 1, 2 + Zone 20, 21, 22
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For wall mounting, plastic
$1,35460
In stock
+
MET841.XXW2E
Explosion Protection:
Without, for Ex-free area (CE, UKCA, c-UL-us, RCM)
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,29350
In stock
+
MET841.XXW2C
Explosion Protection:
Without, for Ex-free area (CE, UKCA, c-UL-us, RCM)
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For wall mounting, plastic
$1,31300
In stock
+
MET841.XXWSE
Explosion Protection:
Without, for Ex-free area (CE, UKCA, c-UL-us, RCM)
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,25190
In stock
+
MET841.XXWSC
Explosion Protection:
Without, for Ex-free area (CE, UKCA, c-UL-us, RCM)
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For wall mounting, plastic
$1,24670
In stock
+
MET841.XXW1E
Explosion Protection:
Without, for Ex-free area (CE, UKCA, c-UL-us, RCM)
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,18560
In stock
+
MET841.XXW1C
Explosion Protection:
Without, for Ex-free area (CE, UKCA, c-UL-us, RCM)
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For wall mounting, plastic
$1,30000
In stock
+
MET841.XXX2E
Explosion Protection:
Without, for Ex-free area (CE, UKCA, c-UL-us, RCM)
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,23890
In stock
+
MET841.XXX2C
Explosion Protection:
Without, for Ex-free area (CE, UKCA, c-UL-us, RCM)
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For wall mounting, plastic
$1,25840
In stock
+
MET841.XXXSE
Explosion Protection:
Without, for Ex-free area (CE, UKCA, c-UL-us, RCM)
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,19730
In stock
+
MET841.XXXSC
Explosion Protection:
Without, for Ex-free area (CE, UKCA, c-UL-us, RCM)
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For wall mounting, plastic
$1,19210
In stock
+
MET841.XXX1E
Explosion Protection:
Without, for Ex-free area (CE, UKCA, c-UL-us, RCM)
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
$1,13100
In stock
+
MET841.XXX1C
Explosion Protection:
Without, for Ex-free area (CE, UKCA, c-UL-us, RCM)
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For wall mounting, plastic

Features

  • 4 to 20mA sensor input
  • Type of input (selectable):
    • Active input sensor supply through VEGAMET 841
    • Passive input sensor has own voltage supply
  • 0/4 to 20mA, 20 to 0/4mA current output
  • Relay output:
    • 3 operating relays, one can be configured as fail safe relay
    • Switching voltage: max 250 V AC/60 V DC
    • Switching current: max 1 A AC (cos phi > 0.9), 1 A DC
  • ATEX / Europe, IEC / worldwide, c-UL-us, UKEX approvals
  • IP66/IP67, Type 4X protection rating
  • Bluetooth 5.0
  • Simple and reliable commissioning and diagnosis of the measuring points via smartphone
  • Easy-to-read display from a distance, even in sunlight and darkness

The VEGA VEGAMET 841 controller feeds the connected 4 to 20mA sensor, processes the measured values, and displays them. A large display for data visualization is integrated in the housing designed for rough field conditions.

The VEGAMET 841 enables a simple conversion of pump controls, flow measurements on open channels, and weirs and totalizers. The VEGAMET 841 allows limit values to be reliably monitored and relays to be switched, for example, for an overfill protection according to WHG.

VEGAMET-841-datasheet (VEGAMET-841-datasheet.pdf, 355 Kb) [Download]

VEGAMET-841-manual (VEGAMET-841-manual.pdf, 2,526 Kb) [Download]

You may be interested
  • Most Popular
  • On Sale
  • Recently Viewed
 
Fast and high quality delivery

Our company makes delivery all over the country

Quality assurance and service

We offer only those goods, in which quality we are sure

Returns within 30 days

You have 30 days to test your purchase