Rosemount Analytical 1066 Liquid Analytical Transmitter Ozone Analog 4-20mA output with superimposed HART® digital signal CSA/CUS approved, intrinsically safe and non-incendive

1066-OZ-HT-69
£81941
In stock
+
Add to wish list
Delivery
Payment options
Our advantages
  • — 12 months warranty
  • — SMS notification
  • — Return and exchange
  • — Different payment methods
  • — Best price
Column filling
Sort by Price Sort by Availability Sort by CODE Sort by Agency Approval Sort by Communication Sort by Measurement
£67489
In stock
+
1066-CL-HT-60
Agency Approval:
None
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Chlorine
£81941
In stock
+
1066-CL-HT-73
Agency Approval:
ATEX/IECEx approved, intrinsically safe
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Chlorine
£81941
In stock
+
1066-CL-HT-69
Agency Approval:
CSA/CUS approved, intrinsically safe and non-incendive
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Chlorine
£81941
In stock
+
1066-CL-HT-67
Agency Approval:
FM approved, intrinsically safe, and non-incendive
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Chlorine
£1,46181
In stock
+
1066-CL-FF-60
Agency Approval:
None
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Chlorine
£1,60633
In stock
+
1066-CL-FF-73
Agency Approval:
ATEX/IECEx approved, intrinsically safe
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Chlorine
£1,60633
In stock
+
1066-CL-FF-69
Agency Approval:
CSA/CUS approved, intrinsically safe and non-incendive
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Chlorine
£1,60633
In stock
+
1066-CL-FF-67
Agency Approval:
FM approved, intrinsically safe, and non-incendive
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Chlorine
£1,58005
In stock
+
1066-CL-FI-60
Agency Approval:
None
Communication:
FOUNDATION™ fieldbus digital output with FISCO
Measurement:
Chlorine
£1,72457
In stock
+
1066-CL-FI-73
Agency Approval:
ATEX/IECEx approved, intrinsically safe
Communication:
FOUNDATION™ fieldbus digital output with FISCO
Measurement:
Chlorine
£1,72457
In stock
+
1066-CL-FI-69
Agency Approval:
CSA/CUS approved, intrinsically safe and non-incendive
Communication:
FOUNDATION™ fieldbus digital output with FISCO
Measurement:
Chlorine
£1,72457
In stock
+
1066-CL-FI-67
Agency Approval:
FM approved, intrinsically safe, and non-incendive
Communication:
FOUNDATION™ fieldbus digital output with FISCO
Measurement:
Chlorine
Contact us for a price
In stock
1066-C-HT-60
Agency Approval:
None
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Contacting conductivity
£14452
In stock
+
1066-C-HT-73
Agency Approval:
ATEX/IECEx approved, intrinsically safe
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Contacting conductivity
£14452
In stock
+
1066-C-HT-69
Agency Approval:
CSA/CUS approved, intrinsically safe and non-incendive
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Contacting conductivity
£14452
In stock
+
1066-C-HT-67
Agency Approval:
FM approved, intrinsically safe, and non-incendive
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Contacting conductivity
£78691
In stock
+
1066-C-FF-60
Agency Approval:
None
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Contacting conductivity
£93144
In stock
+
1066-C-FF-73
Agency Approval:
ATEX/IECEx approved, intrinsically safe
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Contacting conductivity
£93144
In stock
+
1066-C-FF-69
Agency Approval:
CSA/CUS approved, intrinsically safe and non-incendive
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Contacting conductivity
£93144
In stock
+
1066-C-FF-67
Agency Approval:
FM approved, intrinsically safe, and non-incendive
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Contacting conductivity
£90516
In stock
+
1066-C-FI-60
Agency Approval:
None
Communication:
FOUNDATION™ fieldbus digital output with FISCO
Measurement:
Contacting conductivity
£1,04968
In stock
+
1066-C-FI-73
Agency Approval:
ATEX/IECEx approved, intrinsically safe
Communication:
FOUNDATION™ fieldbus digital output with FISCO
Measurement:
Contacting conductivity
£1,04968
In stock
+
1066-C-FI-69
Agency Approval:
CSA/CUS approved, intrinsically safe and non-incendive
Communication:
FOUNDATION™ fieldbus digital output with FISCO
Measurement:
Contacting conductivity
£1,04968
In stock
+
1066-C-FI-67
Agency Approval:
FM approved, intrinsically safe, and non-incendive
Communication:
FOUNDATION™ fieldbus digital output with FISCO
Measurement:
Contacting conductivity
£67489
In stock
+
1066-DO-HT-60
Agency Approval:
None
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Dissolved oxygen
£81941
In stock
+
1066-DO-HT-73
Agency Approval:
ATEX/IECEx approved, intrinsically safe
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Dissolved oxygen
£81941
In stock
+
1066-DO-HT-69
Agency Approval:
CSA/CUS approved, intrinsically safe and non-incendive
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Dissolved oxygen
£81941
In stock
+
1066-DO-HT-67
Agency Approval:
FM approved, intrinsically safe, and non-incendive
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Dissolved oxygen
£1,46181
In stock
+
1066-DO-FF-60
Agency Approval:
None
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Dissolved oxygen
£1,60633
In stock
+
1066-DO-FF-73
Agency Approval:
ATEX/IECEx approved, intrinsically safe
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Dissolved oxygen
£1,60633
In stock
+
1066-DO-FF-69
Agency Approval:
CSA/CUS approved, intrinsically safe and non-incendive
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Dissolved oxygen
£1,60633
In stock
+
1066-DO-FF-67
Agency Approval:
FM approved, intrinsically safe, and non-incendive
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Dissolved oxygen
£1,58005
In stock
+
1066-DO-FI-60
Agency Approval:
None
Communication:
FOUNDATION™ fieldbus digital output with FISCO
Measurement:
Dissolved oxygen
£1,72457
In stock
+
1066-DO-FI-73
Agency Approval:
ATEX/IECEx approved, intrinsically safe
Communication:
FOUNDATION™ fieldbus digital output with FISCO
Measurement:
Dissolved oxygen
£1,72457
In stock
+
1066-DO-FI-69
Agency Approval:
CSA/CUS approved, intrinsically safe and non-incendive
Communication:
FOUNDATION™ fieldbus digital output with FISCO
Measurement:
Dissolved oxygen
£1,72457
In stock
+
1066-DO-FI-67
Agency Approval:
FM approved, intrinsically safe, and non-incendive
Communication:
FOUNDATION™ fieldbus digital output with FISCO
Measurement:
Dissolved oxygen
£67489
In stock
+
1066-OZ-HT-60
Agency Approval:
None
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Ozone
£81941
In stock
+
1066-OZ-HT-73
Agency Approval:
ATEX/IECEx approved, intrinsically safe
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Ozone
£81941
In stock
+
1066-OZ-HT-69
Agency Approval:
CSA/CUS approved, intrinsically safe and non-incendive
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Ozone
£81941
In stock
+
1066-OZ-HT-67
Agency Approval:
FM approved, intrinsically safe, and non-incendive
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Ozone
£1,46181
In stock
+
1066-OZ-FF-60
Agency Approval:
None
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Ozone
£1,60633
In stock
+
1066-OZ-FF-73
Agency Approval:
ATEX/IECEx approved, intrinsically safe
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Ozone
£1,60633
In stock
+
1066-OZ-FF-69
Agency Approval:
CSA/CUS approved, intrinsically safe and non-incendive
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Ozone
£1,60633
In stock
+
1066-OZ-FF-67
Agency Approval:
FM approved, intrinsically safe, and non-incendive
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Ozone
£1,58005
In stock
+
1066-OZ-FI-60
Agency Approval:
None
Communication:
FOUNDATION™ fieldbus digital output with FISCO
Measurement:
Ozone
£1,72457
In stock
+
1066-OZ-FI-73
Agency Approval:
ATEX/IECEx approved, intrinsically safe
Communication:
FOUNDATION™ fieldbus digital output with FISCO
Measurement:
Ozone
£1,72457
In stock
+
1066-OZ-FI-69
Agency Approval:
CSA/CUS approved, intrinsically safe and non-incendive
Communication:
FOUNDATION™ fieldbus digital output with FISCO
Measurement:
Ozone
£1,72457
In stock
+
1066-OZ-FI-67
Agency Approval:
FM approved, intrinsically safe, and non-incendive
Communication:
FOUNDATION™ fieldbus digital output with FISCO
Measurement:
Ozone
Contact us for a price
In stock
1066-P-HT-60
Agency Approval:
None
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
pH/ORP
£14452
In stock
+
1066-P-HT-73
Agency Approval:
ATEX/IECEx approved, intrinsically safe
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
pH/ORP
£14452
In stock
+
1066-P-HT-69
Agency Approval:
CSA/CUS approved, intrinsically safe and non-incendive
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
pH/ORP
£14452
In stock
+
1066-P-HT-67
Agency Approval:
FM approved, intrinsically safe, and non-incendive
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
pH/ORP
£78691
In stock
+
1066-P-FF-60
Agency Approval:
None
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
pH/ORP
£93144
In stock
+
1066-P-FF-73
Agency Approval:
ATEX/IECEx approved, intrinsically safe
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
pH/ORP
£93144
In stock
+
1066-P-FF-69
Agency Approval:
CSA/CUS approved, intrinsically safe and non-incendive
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
pH/ORP
£93144
In stock
+
1066-P-FF-67
Agency Approval:
FM approved, intrinsically safe, and non-incendive
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
pH/ORP
£90516
In stock
+
1066-P-FI-60
Agency Approval:
None
Communication:
FOUNDATION™ fieldbus digital output with FISCO
Measurement:
pH/ORP
£1,04968
In stock
+
1066-P-FI-73
Agency Approval:
ATEX/IECEx approved, intrinsically safe
Communication:
FOUNDATION™ fieldbus digital output with FISCO
Measurement:
pH/ORP
£1,04968
In stock
+
1066-P-FI-69
Agency Approval:
CSA/CUS approved, intrinsically safe and non-incendive
Communication:
FOUNDATION™ fieldbus digital output with FISCO
Measurement:
pH/ORP
£1,04968
In stock
+
1066-P-FI-67
Agency Approval:
FM approved, intrinsically safe, and non-incendive
Communication:
FOUNDATION™ fieldbus digital output with FISCO
Measurement:
pH/ORP
Contact us for a price
In stock
1066-T-HT-60
Agency Approval:
None
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Toroidal conductivity
£14452
In stock
+
1066-T-HT-73
Agency Approval:
ATEX/IECEx approved, intrinsically safe
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Toroidal conductivity
£14452
In stock
+
1066-T-HT-69
Agency Approval:
CSA/CUS approved, intrinsically safe and non-incendive
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Toroidal conductivity
£14452
In stock
+
1066-T-HT-67
Agency Approval:
FM approved, intrinsically safe, and non-incendive
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Toroidal conductivity
£78691
In stock
+
1066-T-FF-60
Agency Approval:
None
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Toroidal conductivity
£93144
In stock
+
1066-T-FF-73
Agency Approval:
ATEX/IECEx approved, intrinsically safe
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Toroidal conductivity
£93144
In stock
+
1066-T-FF-69
Agency Approval:
CSA/CUS approved, intrinsically safe and non-incendive
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Toroidal conductivity
£93144
In stock
+
1066-T-FF-67
Agency Approval:
FM approved, intrinsically safe, and non-incendive
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Toroidal conductivity
£90516
In stock
+
1066-T-FI-60
Agency Approval:
None
Communication:
FOUNDATION™ fieldbus digital output with FISCO
Measurement:
Toroidal conductivity
£1,04968
In stock
+
1066-T-FI-73
Agency Approval:
ATEX/IECEx approved, intrinsically safe
Communication:
FOUNDATION™ fieldbus digital output with FISCO
Measurement:
Toroidal conductivity
£1,04968
In stock
+
1066-T-FI-69
Agency Approval:
CSA/CUS approved, intrinsically safe and non-incendive
Communication:
FOUNDATION™ fieldbus digital output with FISCO
Measurement:
Toroidal conductivity
£1,04968
In stock
+
1066-T-FI-67
Agency Approval:
FM approved, intrinsically safe, and non-incendive
Communication:
FOUNDATION™ fieldbus digital output with FISCO
Measurement:
Toroidal conductivity

Features

  • Large easy-to-read display
  • HART® version 7 and FOUNDATION® fieldbus communication
  • Intuitive menu screens
  • SMART enabled
  • Two 4-20mA current outputs
  • Polycarbonate. NEMA 4X, IP66
  • Temp Range: -4 to 149°F (-20 to 65°C)
  • Quick start programming
  • Accepts PG 13.5 or1/2" conduit fitting

The Rosemount Analytical 1066 Liquid Analytical Transmitter is a loop-powered analytical unit that serves industrial, commercial and municipal applications with the widest range of liquid measurement inputs available for a two-wire liquid transmitter.

The 1066 SMART transmitter supports continuous measurement of one liquid analytical input. The design supports easy internal access and wiring connections. The large display gives excellent visibility for live measurements and displayed parameters. Conveniently, live process values are always displayed during programming and calibration routines.

The high-contrast LCD provides live measurement readouts in large digits and shows up to four additional variables or diagnostic parameters. The display parameters can be customized to meet user requirements.

Menu screens for calibrating and programming are simple and intuitive. Plain language prompts and help screens guide the user through the procedures. All menu screens are available in eight languages. Live process values are displayed during programming and calibration.

The transmitter continuously monitors itself and the sensor for problems. A display banner on the screen alerts Technicians to Fault and/or Warning conditions. The dedicated Diagnostic key is available for immediate access to specific fault and warning messages and troubleshooting help screens. Extensive diagnostic data is available for pH including Glass Impedance, Reference Impedance, Slope and Offset.

RAI-1066-datasheet (RAI-1066-datasheet.pdf, 1,707 Kb) [Download]

Rosemount-Analytical-1066-Manual (Rosemount-Analytical-1066-Manual.pdf, 6,394 Kb) [Download]

Rosemount_Liquid_Analysis_Wiring_Diagram_Control_Document (Rosemount_Liquid_Analysis_Wiring_Diagram_Control_Document.pdf, 522 Kb) [Download]

You may be interested
  • Most Popular
  • On Sale
  • Recently Viewed
 
Fast and high quality delivery

Our company makes delivery all over the country

Quality assurance and service

We offer only those goods, in which quality we are sure

Returns within 30 days

You have 30 days to test your purchase