Rosemount Analytical Model 5081 Transmitters pH/ORP Analog 4-20mA output with superimposed HART® digital signal With infrared remote controller FM Approved, Intrinsically Safe, non-incendive and explosion-proof

5081-P-HT-20-67
£42527
In stock
+
Add to wish list
Delivery
Payment options
Our advantages
  • — 12 months warranty
  • — SMS notification
  • — Return and exchange
  • — Different payment methods
  • — Best price
Column filling
Sort by Price Sort by Availability Sort by CODE Sort by Agency Approval Sort by Communication Sort by Measurement Sort by Remote Control
£78691
In stock
+
5081-A-HT-21-60
Agency Approval:
None
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Amperometric (dissolved oxygen, ozone & chlorine)
Remote Control:
Not included
£1,05798
In stock
+
5081-A-HT-20-60
Agency Approval:
None
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Amperometric (dissolved oxygen, ozone & chlorine)
Remote Control:
With infrared remote controller
£1,81723
In stock
+
5081-A-FF-21-60
Agency Approval:
None
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Amperometric (dissolved oxygen, ozone & chlorine)
Remote Control:
Not included
£2,08830
In stock
+
5081-A-FF-20-60
Agency Approval:
None
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Amperometric (dissolved oxygen, ozone & chlorine)
Remote Control:
With infrared remote controller
Contact us for a price
In stock
5081-C-HT-21-60
Agency Approval:
None
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Contacting conductivity
Remote Control:
Not included
£27106
In stock
+
5081-C-HT-20-60
Agency Approval:
None
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Contacting conductivity
Remote Control:
With infrared remote controller
£42527
In stock
+
5081-C-HT-20-67
Agency Approval:
FM Approved, Intrinsically Safe, non-incendive and explosion-proof
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Contacting conductivity
Remote Control:
With infrared remote controller
£1,03032
In stock
+
5081-C-FF-21-60
Agency Approval:
None
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Contacting conductivity
Remote Control:
Not included
£1,30138
In stock
+
5081-C-FF-20-60
Agency Approval:
None
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Contacting conductivity
Remote Control:
With infrared remote controller
Contact us for a price
In stock
5081-P-HT-21-60
Agency Approval:
None
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
pH/ORP
Remote Control:
Not included
£27106
In stock
+
5081-P-HT-20-60
Agency Approval:
None
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
pH/ORP
Remote Control:
With infrared remote controller
£42527
In stock
+
5081-P-HT-20-67
Agency Approval:
FM Approved, Intrinsically Safe, non-incendive and explosion-proof
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
pH/ORP
Remote Control:
With infrared remote controller
£1,03032
In stock
+
5081-P-FF-21-60
Agency Approval:
None
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
pH/ORP
Remote Control:
Not included
£1,30138
In stock
+
5081-P-FF-20-60
Agency Approval:
None
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
pH/ORP
Remote Control:
With infrared remote controller
Contact us for a price
In stock
5081-T-HT-21-60
Agency Approval:
None
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Toroidal conductivity
Remote Control:
Not included
£27106
In stock
+
5081-T-HT-20-60
Agency Approval:
None
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Toroidal conductivity
Remote Control:
With infrared remote controller
£42527
In stock
+
5081-T-HT-20-67
Agency Approval:
FM Approved, Intrinsically Safe, non-incendive and explosion-proof
Communication:
Analog 4-20mA output with superimposed HART® digital signal
Measurement:
Toroidal conductivity
Remote Control:
With infrared remote controller
£1,03032
In stock
+
5081-T-FF-21-60
Agency Approval:
None
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Toroidal conductivity
Remote Control:
Not included
£1,30138
In stock
+
5081-T-FF-20-60
Agency Approval:
None
Communication:
FOUNDATION™ fieldbus digital output
Measurement:
Toroidal conductivity
Remote Control:
With infrared remote controller

Features

  • Measures pH, ORP, conductivity, resistivity, oxygen, chlorine, and ozone in a variety of process liquids
  • Compatible with most Rosemount Analytical sensors
  • Choice of HART or FOUNDATION Fieldbus communications protocol
  • Large, easy to read two-line display shows the process measurement and temperature
  • Simple menu structure
  • Robust NEMA 4X and NEMA 7B enclosure
  • Optional intrinsically safe design allows the transmitter to be used in hazardous environments (with appropriate safety barriers)
  • Non-volatile memory retains program settings and calibration data during power failures

The Rosemount Analytical Model 5081 family of transmitters can be used to measure pH, ORP, conductivity (using either contacting or toroidal sensors), resistivity, oxygen, free chlorine, total chlorine, and ozone in a variety of process liquids. The 5081 is compatible with most Rosemount Analytical sensors. With a rugged, weatherproof, corrosion-resistant enclosure (NEMA 4X and IP65) of epoxy-painted aluminum, the 5081 meets NEMA 7B explosion-proof standards making it possible to locate the transmitter close to the sensor even in the harshest environments.

The Rosemount Analytical 5081 transmitter is simple to set-up and operate. A large, easy to read two-line display shows the process measurement and temperature. The 5081 includes the HART or Foundation Fieldbus digital communication protocols which allows users to set-up, configure, read process variables, and troubleshoot problems via PC or HART communicator. Additionally, an optional handheld infrared remote controller can also be used for programming and calibrating the transmitter. The remote controller works from as far away as six feet.

Models of the Rosemount Analytical Xmt family of transmitters:

  • 5081–A:

    Amperometric transmitter measures dissolved oxygen (ppm and ppb level), free chlorine, total chlorine, and ozone
  • 5081–P:

    pH/ORP transmitter
  • 5081–C:

    Contacting conductivity transmitter measures conductivity, resistivity, or custom curve variable
  • 5081–T:

    Toroidal conductivity transmitter measures conductivity, percent concentration, or custom curve variable

5081-datasheet (5081-datasheet.pdf, 580 Kb) [Download]

Rosemount-Analytical-Model-5081-Transmitters-Manual (Rosemount-Analytical-Model-5081-Transmitters-Manual.pdf, 16,370 Kb) [Download]

Rosemount-Analytical-5081-HT-Manual (Rosemount-Analytical-5081-HT-Manual.pdf, 5,366 Kb) [Download]

5081-A-FF-manual (5081-A-FF-manual.pdf, 3,764 Kb) [Download]

5081-C-manual (5081-C-manual.pdf, 580 Kb) [Download]

5081-P-manual (5081-P-manual.pdf, 5,366 Kb) [Download]

5081-T-manual (5081-T-manual.pdf, 4,037 Kb) [Download]

Rosemount_Liquid_Analysis_Wiring_Diagram_Control_Document (Rosemount_Liquid_Analysis_Wiring_Diagram_Control_Document.pdf, 522 Kb) [Download]

You may be interested
  • Most Popular
  • On Sale
  • Recently Viewed
 
Fast and high quality delivery

Our company makes delivery all over the country

Quality assurance and service

We offer only those goods, in which quality we are sure

Returns within 30 days

You have 30 days to test your purchase