GF Signet 2819-2823 Conductivity / Resistivity Electrodes 1.0 µS/cm cell 316 SS electrode; Sanitary Tri-clamp flange: insertion into 2" tee NIST traceable certification

3-2821-S2C
1,42492
In stock
+
Add to wish list
Delivery
Payment options
Our advantages
  • — 12 months warranty
  • — SMS notification
  • — Return and exchange
  • — Different payment methods
  • — Best price
Column filling
Sort by Price Sort by Availability Sort by CODE Sort by Certification Sort by Range Sort by Sensor Material and Mounting
60125
In stock
+
3-2819-1
Certification:
None
Range:
0.01 µS/cm cell
Sensor Material and Mounting:
316 SS electrode with 3/4" threads
60125
In stock
+
3-2819-1C
Certification:
NIST traceable certification
Range:
0.01 µS/cm cell
Sensor Material and Mounting:
316 SS electrode with 3/4" threads
1,20758
In stock
+
3-2819-S1
Certification:
None
Range:
0.01 µS/cm cell
Sensor Material and Mounting:
316 SS electrode; Sanitary Tri-clamp flange: insertion into 1 to 1.5" tee
1,20758
In stock
+
3-2819-S1C
Certification:
NIST traceable certification
Range:
0.01 µS/cm cell
Sensor Material and Mounting:
316 SS electrode; Sanitary Tri-clamp flange: insertion into 1 to 1.5" tee
1,42695
In stock
+
3-2819-S2
Certification:
None
Range:
0.01 µS/cm cell
Sensor Material and Mounting:
316 SS electrode; Sanitary Tri-clamp flange: insertion into 2" tee
1,42695
In stock
+
3-2819-S2C
Certification:
NIST traceable certification
Range:
0.01 µS/cm cell
Sensor Material and Mounting:
316 SS electrode; Sanitary Tri-clamp flange: insertion into 2" tee
1,77328
In stock
+
3-2819-T1
Certification:
None
Range:
0.01 µS/cm cell
Sensor Material and Mounting:
Titanium electrode; Sanitary Tri-clamp flange: insertion into 1 to 1.5" tee
1,77328
In stock
+
3-2819-T1C
Certification:
NIST traceable certification
Range:
0.01 µS/cm cell
Sensor Material and Mounting:
Titanium electrode; Sanitary Tri-clamp flange: insertion into 1 to 1.5" tee
1,91344
In stock
+
3-2819-T2
Certification:
None
Range:
0.01 µS/cm cell
Sensor Material and Mounting:
Titanium electrode; Sanitary Tri-clamp flange: insertion into 2" tee
1,91344
In stock
+
3-2819-T2C
Certification:
NIST traceable certification
Range:
0.01 µS/cm cell
Sensor Material and Mounting:
Titanium electrode; Sanitary Tri-clamp flange: insertion into 2" tee
59922
In stock
+
3-2820-1
Certification:
None
Range:
0.1 µS/cm cell
Sensor Material and Mounting:
316 SS electrode with 3/4" threads
59922
In stock
+
3-2820-1C
Certification:
NIST traceable certification
Range:
0.1 µS/cm cell
Sensor Material and Mounting:
316 SS electrode with 3/4" threads
1,20555
In stock
+
3-2820-S1
Certification:
None
Range:
0.1 µS/cm cell
Sensor Material and Mounting:
316 SS electrode; Sanitary Tri-clamp flange: insertion into 1 to 1.5" tee
1,20555
In stock
+
3-2820-S1C
Certification:
NIST traceable certification
Range:
0.1 µS/cm cell
Sensor Material and Mounting:
316 SS electrode; Sanitary Tri-clamp flange: insertion into 1 to 1.5" tee
1,42492
In stock
+
3-2820-S2
Certification:
None
Range:
0.1 µS/cm cell
Sensor Material and Mounting:
316 SS electrode; Sanitary Tri-clamp flange: insertion into 2" tee
1,42492
In stock
+
3-2820-S2C
Certification:
NIST traceable certification
Range:
0.1 µS/cm cell
Sensor Material and Mounting:
316 SS electrode; Sanitary Tri-clamp flange: insertion into 2" tee
1,77125
In stock
+
3-2820-T1
Certification:
None
Range:
0.1 µS/cm cell
Sensor Material and Mounting:
Titanium electrode; Sanitary Tri-clamp flange: insertion into 1 to 1.5" tee
1,77125
In stock
+
3-2820-T1C
Certification:
NIST traceable certification
Range:
0.1 µS/cm cell
Sensor Material and Mounting:
Titanium electrode; Sanitary Tri-clamp flange: insertion into 1 to 1.5" tee
1,91141
In stock
+
3-2820-T2
Certification:
None
Range:
0.1 µS/cm cell
Sensor Material and Mounting:
Titanium electrode; Sanitary Tri-clamp flange: insertion into 2" tee
1,91141
In stock
+
3-2820-T2C
Certification:
NIST traceable certification
Range:
0.1 µS/cm cell
Sensor Material and Mounting:
Titanium electrode; Sanitary Tri-clamp flange: insertion into 2" tee
59922
In stock
+
3-2821-1
Certification:
None
Range:
1.0 µS/cm cell
Sensor Material and Mounting:
316 SS electrode with 3/4" threads
59922
In stock
+
3-2821-1C
Certification:
NIST traceable certification
Range:
1.0 µS/cm cell
Sensor Material and Mounting:
316 SS electrode with 3/4" threads
1,20555
In stock
+
3-2821-S1
Certification:
None
Range:
1.0 µS/cm cell
Sensor Material and Mounting:
316 SS electrode; Sanitary Tri-clamp flange: insertion into 1 to 1.5" tee
1,20555
In stock
+
3-2821-S1C
Certification:
NIST traceable certification
Range:
1.0 µS/cm cell
Sensor Material and Mounting:
316 SS electrode; Sanitary Tri-clamp flange: insertion into 1 to 1.5" tee
1,42492
In stock
+
3-2821-S2
Certification:
None
Range:
1.0 µS/cm cell
Sensor Material and Mounting:
316 SS electrode; Sanitary Tri-clamp flange: insertion into 2" tee
1,42492
In stock
+
3-2821-S2C
Certification:
NIST traceable certification
Range:
1.0 µS/cm cell
Sensor Material and Mounting:
316 SS electrode; Sanitary Tri-clamp flange: insertion into 2" tee
1,77125
In stock
+
3-2821-T1
Certification:
None
Range:
1.0 µS/cm cell
Sensor Material and Mounting:
Titanium electrode; Sanitary Tri-clamp flange: insertion into 1 to 1.5" tee
1,77125
In stock
+
3-2821-T1C
Certification:
NIST traceable certification
Range:
1.0 µS/cm cell
Sensor Material and Mounting:
Titanium electrode; Sanitary Tri-clamp flange: insertion into 1 to 1.5" tee
1,91141
In stock
+
3-2821-T2
Certification:
None
Range:
1.0 µS/cm cell
Sensor Material and Mounting:
Titanium electrode; Sanitary Tri-clamp flange: insertion into 2" tee
1,91141
In stock
+
3-2821-T2C
Certification:
NIST traceable certification
Range:
1.0 µS/cm cell
Sensor Material and Mounting:
Titanium electrode; Sanitary Tri-clamp flange: insertion into 2" tee
1,00242
In stock
+
3-2822-1
Certification:
None
Range:
10 µS/cm cell
Sensor Material and Mounting:
316 SS electrode with 3/4" threads
1,00242
In stock
+
3-2822-1C
Certification:
NIST traceable certification
Range:
10 µS/cm cell
Sensor Material and Mounting:
316 SS electrode with 3/4" threads
1,60875
In stock
+
3-2822-S1
Certification:
None
Range:
10 µS/cm cell
Sensor Material and Mounting:
316 SS electrode; Sanitary Tri-clamp flange: insertion into 1 to 1.5" tee
1,60875
In stock
+
3-2822-S1C
Certification:
NIST traceable certification
Range:
10 µS/cm cell
Sensor Material and Mounting:
316 SS electrode; Sanitary Tri-clamp flange: insertion into 1 to 1.5" tee
1,82813
In stock
+
3-2822-S2
Certification:
None
Range:
10 µS/cm cell
Sensor Material and Mounting:
316 SS electrode; Sanitary Tri-clamp flange: insertion into 2" tee
1,82813
In stock
+
3-2822-S2C
Certification:
NIST traceable certification
Range:
10 µS/cm cell
Sensor Material and Mounting:
316 SS electrode; Sanitary Tri-clamp flange: insertion into 2" tee
2,17445
In stock
+
3-2822-T1
Certification:
None
Range:
10 µS/cm cell
Sensor Material and Mounting:
Titanium electrode; Sanitary Tri-clamp flange: insertion into 1 to 1.5" tee
2,17445
In stock
+
3-2822-T1C
Certification:
NIST traceable certification
Range:
10 µS/cm cell
Sensor Material and Mounting:
Titanium electrode; Sanitary Tri-clamp flange: insertion into 1 to 1.5" tee
2,31461
In stock
+
3-2822-T2
Certification:
None
Range:
10 µS/cm cell
Sensor Material and Mounting:
Titanium electrode; Sanitary Tri-clamp flange: insertion into 2" tee
2,31461
In stock
+
3-2822-T2C
Certification:
NIST traceable certification
Range:
10 µS/cm cell
Sensor Material and Mounting:
Titanium electrode; Sanitary Tri-clamp flange: insertion into 2" tee
1,20453
In stock
+
3-2823-1
Certification:
None
Range:
20 µS/cm cell
Sensor Material and Mounting:
316 SS electrode with 3/4" threads
1,20453
In stock
+
3-2823-1C
Certification:
NIST traceable certification
Range:
20 µS/cm cell
Sensor Material and Mounting:
316 SS electrode with 3/4" threads
1,81086
In stock
+
3-2823-S1
Certification:
None
Range:
20 µS/cm cell
Sensor Material and Mounting:
316 SS electrode; Sanitary Tri-clamp flange: insertion into 1 to 1.5" tee
1,81086
In stock
+
3-2823-S1C
Certification:
NIST traceable certification
Range:
20 µS/cm cell
Sensor Material and Mounting:
316 SS electrode; Sanitary Tri-clamp flange: insertion into 1 to 1.5" tee
2,03023
In stock
+
3-2823-S2
Certification:
None
Range:
20 µS/cm cell
Sensor Material and Mounting:
316 SS electrode; Sanitary Tri-clamp flange: insertion into 2" tee
2,03023
In stock
+
3-2823-S2C
Certification:
NIST traceable certification
Range:
20 µS/cm cell
Sensor Material and Mounting:
316 SS electrode; Sanitary Tri-clamp flange: insertion into 2" tee
2,37656
In stock
+
3-2823-T1
Certification:
None
Range:
20 µS/cm cell
Sensor Material and Mounting:
Titanium electrode; Sanitary Tri-clamp flange: insertion into 1 to 1.5" tee
2,37656
In stock
+
3-2823-T1C
Certification:
NIST traceable certification
Range:
20 µS/cm cell
Sensor Material and Mounting:
Titanium electrode; Sanitary Tri-clamp flange: insertion into 1 to 1.5" tee
2,51672
In stock
+
3-2823-T2
Certification:
None
Range:
20 µS/cm cell
Sensor Material and Mounting:
Titanium electrode; Sanitary Tri-clamp flange: insertion into 2" tee
2,51672
In stock
+
3-2823-T2C
Certification:
NIST traceable certification
Range:
20 µS/cm cell
Sensor Material and Mounting:
Titanium electrode; Sanitary Tri-clamp flange: insertion into 2" tee

Features

  • Range of process connections
  • 316 SS or Titanium electrodes
  • In-line or submersible (models 2822 and 2833) mounting
  • Accuracy: ±2% meet USP requirements
  • Controlled surface finish ensures accuracy and repeatability
  • Flow-through design
  • PTFE insulator (PEEK insulator for 3-2823-1)
  • Includes 15' of cable

GF Signet 2819-2823 Conductivity/Resistivity Electrodes are designed to provide highly accurate sensing across a very broad dynamic range. These GF Signet 2819-2823 Conductivity/Resistivity Electrodes are built with a controlled surface finish to ensure accuracy and repeatability.

The standard GF Signet 2819-2823 Conductivity/Resistivity Electrode is constructed from 316SS or Titanium, but there are other materials available for maximum chemical compatibility. Reversible threads or sanitary flanges allow for maximum installation versatility. Sanitary flange versions of the GF Signet 2819-2823 Conductivity/Resistivity Electrode are available with an optional NIST Traceability Certificate to meet USP requirements. A platinum RTD (PT-1000) located within the electrode allows optimal temperature sensing.

Applications for the GF Signet 2819-2823 Conductivity/Resistivity Electrode

  • Pure Water Treatment (Reverse Osmosis, Deionization, Distillation)
  • Boiler Condensate
  • Semiconductor Water Production
  • Rinse Water Monitoring and Control
  • Chemical Concentrations
  • Cleaner and Degreaser Concentrations
  • TDS (Total Dissolved Solids)
  • Salinity
  • USP Purified Water
  • WFI Water Production
  • Ultra Pure Water

System Compatibility

The GF Signet 2819-2823 Conductivity/Resistivity Electrode is compatible with a wide variety of GF Signet components. Please click here to view typical system configurations. If you have any questions about your particular installation, please contact us.

GFSignet-2818-2823-datasheet (GFSignet-2818-2823-datasheet.pdf, 729 Kb) [Download]

GFSignet-2818-2823-manual (GFSignet-2818-2823-manual.pdf, 688 Kb) [Download]

Analytical_compatibility (Analytical_compatibility.pdf, 103 Kb) [Download]

TechnicalReference_Conductivity (TechnicalReference_Conductivity.pdf, 243 Kb) [Download]

You may be interested
  • Most Popular
  • On Sale
  • Recently Viewed
 
Fast and high quality delivery

Our company makes delivery all over the country

Quality assurance and service

We offer only those goods, in which quality we are sure

Returns within 30 days

You have 30 days to test your purchase