ICON ProCon C450 Series Conductivity Sensor Transmitter 0.01, 0-100μS RS485 and 4-20mA PT1000 (standard) M12

C450-G-S-1-M
86227
In stock
+
Add to wish list
Delivery
Payment options
Our advantages
  • — 12 months warranty
  • — SMS notification
  • — Return and exchange
  • — Different payment methods
  • — Best price
Column filling
Sort by Price Sort by Availability Sort by CODE Sort by Output Sort by Connection Sort by Cell Constant Sort by Electode
86227
In stock
+
C450-G-M-1-F
Output:
4-20mA (2-wire)
Connection:
Flying Lead
Cell Constant:
0.01, 0-100μS
Electode:
PT1000 (standard)
76070
In stock
+
C450-G-M-1-M
Output:
4-20mA (2-wire)
Connection:
M12
Cell Constant:
0.01, 0-100μS
Electode:
PT1000 (standard)
76070
In stock
+
C450-G-D-1-F
Output:
4-wire (for ProCon Display)
Connection:
Flying Lead
Cell Constant:
0.01, 0-100μS
Electode:
PT1000 (standard)
65914
In stock
+
C450-G-D-1-M
Output:
4-wire (for ProCon Display)
Connection:
M12
Cell Constant:
0.01, 0-100μS
Electode:
PT1000 (standard)
96383
In stock
+
C450-G-S-1-F
Output:
RS485 and 4-20mA
Connection:
Flying Lead
Cell Constant:
0.01, 0-100μS
Electode:
PT1000 (standard)
86227
In stock
+
C450-G-S-1-M
Output:
RS485 and 4-20mA
Connection:
M12
Cell Constant:
0.01, 0-100μS
Electode:
PT1000 (standard)
86227
In stock
+
C450-J-M-1-F
Output:
4-20mA (2-wire)
Connection:
Flying Lead
Cell Constant:
0.1, 0-1,000μS
Electode:
PT1000 (standard)
76070
In stock
+
C450-J-M-1-M
Output:
4-20mA (2-wire)
Connection:
M12
Cell Constant:
0.1, 0-1,000μS
Electode:
PT1000 (standard)
76070
In stock
+
C450-J-D-1-F
Output:
4-wire (for ProCon Display)
Connection:
Flying Lead
Cell Constant:
0.1, 0-1,000μS
Electode:
PT1000 (standard)
65914
In stock
+
C450-J-D-1-M
Output:
4-wire (for ProCon Display)
Connection:
M12
Cell Constant:
0.1, 0-1,000μS
Electode:
PT1000 (standard)
96383
In stock
+
C450-J-S-1-F
Output:
RS485 and 4-20mA
Connection:
Flying Lead
Cell Constant:
0.1, 0-1,000μS
Electode:
PT1000 (standard)
86227
In stock
+
C450-J-S-1-M
Output:
RS485 and 4-20mA
Connection:
M12
Cell Constant:
0.1, 0-1,000μS
Electode:
PT1000 (standard)
86227
In stock
+
C450-M-M-1-F
Output:
4-20mA (2-wire)
Connection:
Flying Lead
Cell Constant:
1.0, 0-10,000μS
Electode:
PT1000 (standard)
76070
In stock
+
C450-M-M-1-M
Output:
4-20mA (2-wire)
Connection:
M12
Cell Constant:
1.0, 0-10,000μS
Electode:
PT1000 (standard)
76070
In stock
+
C450-M-D-1-F
Output:
4-wire (for ProCon Display)
Connection:
Flying Lead
Cell Constant:
1.0, 0-10,000μS
Electode:
PT1000 (standard)
65914
In stock
+
C450-M-D-1-M
Output:
4-wire (for ProCon Display)
Connection:
M12
Cell Constant:
1.0, 0-10,000μS
Electode:
PT1000 (standard)
96383
In stock
+
C450-M-S-1-F
Output:
RS485 and 4-20mA
Connection:
Flying Lead
Cell Constant:
1.0, 0-10,000μS
Electode:
PT1000 (standard)
86227
In stock
+
C450-M-S-1-M
Output:
RS485 and 4-20mA
Connection:
M12
Cell Constant:
1.0, 0-10,000μS
Electode:
PT1000 (standard)
86227
In stock
+
C450-P-M-1-F
Output:
4-20mA (2-wire)
Connection:
Flying Lead
Cell Constant:
10, 0-20,000μS
Electode:
PT1000 (standard)
76070
In stock
+
C450-P-M-1-M
Output:
4-20mA (2-wire)
Connection:
M12
Cell Constant:
10, 0-20,000μS
Electode:
PT1000 (standard)
76070
In stock
+
C450-P-D-1-F
Output:
4-wire (for ProCon Display)
Connection:
Flying Lead
Cell Constant:
10, 0-20,000μS
Electode:
PT1000 (standard)
65914
In stock
+
C450-P-D-1-M
Output:
4-wire (for ProCon Display)
Connection:
M12
Cell Constant:
10, 0-20,000μS
Electode:
PT1000 (standard)
96383
In stock
+
C450-P-S-1-F
Output:
RS485 and 4-20mA
Connection:
Flying Lead
Cell Constant:
10, 0-20,000μS
Electode:
PT1000 (standard)
86227
In stock
+
C450-P-S-1-M
Output:
RS485 and 4-20mA
Connection:
M12
Cell Constant:
10, 0-20,000μS
Electode:
PT1000 (standard)

Features

  • 4-20mA and RS485 outputs
  • ±0.5% accuracy
  • 3/4" NPT connection
  • Factory calibrated
  • 2 electrodes
  • IP68 IP rating
  • Pressure rating 150 PSI
  • PT1000 standard temperature compensation
  • Measurement range 0-200,000μS
  • Temperature range 14-176°F
  • 9-36VDC Power Supply
  • No pre-amp required

The ICON ProCon C450 Series Conductivity Sensor Transmitter is designed for industrial applications in extreme conditions. The sensor transmitter comes pre-calibrated and can be configured with our without a junction box. The C450 also features the convenience and safety of the M12 quick connection with no additional conductivity module required.

The ProCon C450 series double electrode conductivity sensor transmitter has been proven to operate seamlessly in industrial applications up to 200,000μS/cm. The 2-wire 4-20mA, 4-wire or 4.20mA + RS485 output options simplify calibration and communication with remote displays and controllers.

Applications

  • Process Control
  • Water Quality
  • Sanitization Systems
  • Neutralization Systems
  • Effluent Monitoring
  • Pool and Spa Control
  • Aquatic Animal Systems
  • Cooling Towers

rocon-c450-conductivity-sensor-data-sheet2 (procon-c450-conductivity-sensor-data-sheet2.pdf, 1,140 Kb) [Download]

rocon-conductivity-sensor-manual (procon-conductivity-sensor-manual.pdf, 2,045 Kb) [Download]

You may be interested
  • Most Popular
  • On Sale
  • Recently Viewed
 
Fast and high quality delivery

Our company makes delivery all over the country

Quality assurance and service

We offer only those goods, in which quality we are sure

Returns within 30 days

You have 30 days to test your purchase