Ametek RK Pneumatic Deadweight Tester psi 1 to 51 psi (1 psi increments) ±0.015% of reading; standard or local gravity; with calibration report

RK-50-1A/C
16,40742
In stock
+
Add to wish list
Delivery
Payment options
Our advantages
  • — 12 months warranty
  • — SMS notification
  • — Return and exchange
  • — Different payment methods
  • — Best price
Column filling
Sort by Price Sort by Availability Sort by CODE Sort by Calibration Sort by Pressure Range Sort by Pressure Unit
20,20688
In stock
+
RK-12B-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 12 bar (0.01 bar increments)
Pressure Unit:
bar
21,11180
In stock
+
RK-12B-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 12 bar (0.01 bar increments)
Pressure Unit:
bar
18,87742
In stock
+
RK-12B-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 12 bar (0.01 bar increments)
Pressure Unit:
bar
19,77625
In stock
+
RK-12B-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 12 bar (0.01 bar increments)
Pressure Unit:
bar
17,60281
In stock
+
RK-12B
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 12 bar (0.01 bar increments)
Pressure Unit:
bar
18,50773
In stock
+
RK-12B/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 12 bar (0.01 bar increments)
Pressure Unit:
bar
16,88273
In stock
+
RK-2B-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 2 bar (0.01 bar increments)
Pressure Unit:
bar
17,78766
In stock
+
RK-2B-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 2 bar (0.01 bar increments)
Pressure Unit:
bar
15,55328
In stock
+
RK-2B-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 2 bar (0.01 bar increments)
Pressure Unit:
bar
16,45211
In stock
+
RK-2B-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 2 bar (0.01 bar increments)
Pressure Unit:
bar
14,27867
In stock
+
RK-2B
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 2 bar (0.01 bar increments)
Pressure Unit:
bar
15,18359
In stock
+
RK-2B/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 2 bar (0.01 bar increments)
Pressure Unit:
bar
22,43414
In stock
+
RK-20B-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 20 bar (0.01 bar increments)
Pressure Unit:
bar
23,33906
In stock
+
RK-20B-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 20 bar (0.01 bar increments)
Pressure Unit:
bar
21,10469
In stock
+
RK-20B-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 20 bar (0.01 bar increments)
Pressure Unit:
bar
22,00352
In stock
+
RK-20B-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 20 bar (0.01 bar increments)
Pressure Unit:
bar
19,83008
In stock
+
RK-20B
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 20 bar (0.01 bar increments)
Pressure Unit:
bar
20,73500
In stock
+
RK-20B/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 20 bar (0.01 bar increments)
Pressure Unit:
bar
22,43414
In stock
+
RK-20M-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 20 kg/cm² (0.01 kg/cm² increments)
Pressure Unit:
bar
23,33906
In stock
+
RK-20M-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 20 kg/cm² (0.01 kg/cm² increments)
Pressure Unit:
bar
21,10469
In stock
+
RK-20M-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 20 kg/cm² (0.01 kg/cm² increments)
Pressure Unit:
bar
22,00352
In stock
+
RK-20M-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 20 kg/cm² (0.01 kg/cm² increments)
Pressure Unit:
bar
19,83008
In stock
+
RK-20M
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 20 kg/cm² (0.01 kg/cm² increments)
Pressure Unit:
bar
20,73500
In stock
+
RK-20M/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 20 kg/cm² (0.01 kg/cm² increments)
Pressure Unit:
bar
17,82422
In stock
+
RK-4B-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 4 bar (0.01 bar increments)
Pressure Unit:
bar
18,72914
In stock
+
RK-4B-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 4 bar (0.01 bar increments)
Pressure Unit:
bar
16,49477
In stock
+
RK-4B-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 4 bar (0.01 bar increments)
Pressure Unit:
bar
17,39359
In stock
+
RK-4B-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 4 bar (0.01 bar increments)
Pressure Unit:
bar
15,22016
In stock
+
RK-4B
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 4 bar (0.01 bar increments)
Pressure Unit:
bar
16,12508
In stock
+
RK-4B/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 4 bar (0.01 bar increments)
Pressure Unit:
bar
17,82422
In stock
+
RK-4M-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 4 kg/cm² (0.01 kg/cm² increments)
Pressure Unit:
bar
18,72914
In stock
+
RK-4M-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 4 kg/cm² (0.01 kg/cm² increments)
Pressure Unit:
bar
16,49477
In stock
+
RK-4M-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 4 kg/cm² (0.01 kg/cm² increments)
Pressure Unit:
bar
17,39359
In stock
+
RK-4M-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 4 kg/cm² (0.01 kg/cm² increments)
Pressure Unit:
bar
15,22016
In stock
+
RK-4M
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 4 kg/cm² (0.01 kg/cm² increments)
Pressure Unit:
bar
16,12508
In stock
+
RK-4M/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 4 kg/cm² (0.01 kg/cm² increments)
Pressure Unit:
bar
19,05211
In stock
+
RK-8B-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 8 bar (0.01 bar increments)
Pressure Unit:
bar
19,95703
In stock
+
RK-8B-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 8 bar (0.01 bar increments)
Pressure Unit:
bar
17,72266
In stock
+
RK-8B-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 8 bar (0.01 bar increments)
Pressure Unit:
bar
18,62148
In stock
+
RK-8B-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 8 bar (0.01 bar increments)
Pressure Unit:
bar
16,44805
In stock
+
RK-8B
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 8 bar (0.01 bar increments)
Pressure Unit:
bar
17,35297
In stock
+
RK-8B/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 8 bar (0.01 bar increments)
Pressure Unit:
bar
19,05211
In stock
+
RK-8M-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 8 kg/cm² (0.01 kg/cm² increments)
Pressure Unit:
bar
19,95703
In stock
+
RK-8M-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 8 kg/cm² (0.01 kg/cm² increments)
Pressure Unit:
bar
17,72266
In stock
+
RK-8M-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 8 kg/cm² (0.01 kg/cm² increments)
Pressure Unit:
bar
18,62148
In stock
+
RK-8M-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 8 kg/cm² (0.01 kg/cm² increments)
Pressure Unit:
bar
16,44805
In stock
+
RK-8M
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 8 kg/cm² (0.01 kg/cm² increments)
Pressure Unit:
bar
17,35297
In stock
+
RK-8M/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 8 kg/cm² (0.01 kg/cm² increments)
Pressure Unit:
bar
16,99242
In stock
+
RK-100-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 101 psi (1 psi increments)
Pressure Unit:
bar
17,89734
In stock
+
RK-100-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 101 psi (1 psi increments)
Pressure Unit:
bar
15,66297
In stock
+
RK-100-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 101 psi (1 psi increments)
Pressure Unit:
bar
16,56180
In stock
+
RK-100-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 101 psi (1 psi increments)
Pressure Unit:
bar
14,38836
In stock
+
RK-100
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 101 psi (1 psi increments)
Pressure Unit:
bar
15,29328
In stock
+
RK-100/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 101 psi (1 psi increments)
Pressure Unit:
bar
20,20688
In stock
+
RK-1200N-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 1211 kPa (1 kPa increments)
Pressure Unit:
bar
21,11180
In stock
+
RK-1200N-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 1211 kPa (1 kPa increments)
Pressure Unit:
bar
18,87742
In stock
+
RK-1200N-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 1211 kPa (1 kPa increments)
Pressure Unit:
bar
19,77625
In stock
+
RK-1200N-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 1211 kPa (1 kPa increments)
Pressure Unit:
bar
17,60281
In stock
+
RK-1200N
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 1211 kPa (1 kPa increments)
Pressure Unit:
bar
18,50773
In stock
+
RK-1200N/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 1211 kPa (1 kPa increments)
Pressure Unit:
bar
18,99320
In stock
+
RK-200-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 201 psi (1 psi increments)
Pressure Unit:
bar
19,89813
In stock
+
RK-200-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 201 psi (1 psi increments)
Pressure Unit:
bar
17,66375
In stock
+
RK-200-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 201 psi (1 psi increments)
Pressure Unit:
bar
18,56258
In stock
+
RK-200-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 201 psi (1 psi increments)
Pressure Unit:
bar
16,38914
In stock
+
RK-200
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 201 psi (1 psi increments)
Pressure Unit:
bar
17,29406
In stock
+
RK-200/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 201 psi (1 psi increments)
Pressure Unit:
bar
22,43414
In stock
+
RK-2000N-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 2011 kPa (1 kPa increments)
Pressure Unit:
bar
23,33906
In stock
+
RK-2000N-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 2011 kPa (1 kPa increments)
Pressure Unit:
bar
21,10469
In stock
+
RK-2000N-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 2011 kPa (1 kPa increments)
Pressure Unit:
bar
22,00352
In stock
+
RK-2000N-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 2011 kPa (1 kPa increments)
Pressure Unit:
bar
19,83008
In stock
+
RK-2000N
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 2011 kPa (1 kPa increments)
Pressure Unit:
bar
20,73500
In stock
+
RK-2000N/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 2011 kPa (1 kPa increments)
Pressure Unit:
bar
16,88273
In stock
+
RK-200N-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 211 kPa (1 kPa increments)
Pressure Unit:
bar
17,78766
In stock
+
RK-200N-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 211 kPa (1 kPa increments)
Pressure Unit:
bar
15,55328
In stock
+
RK-200N-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 211 kPa (1 kPa increments)
Pressure Unit:
bar
16,45211
In stock
+
RK-200N-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 211 kPa (1 kPa increments)
Pressure Unit:
bar
14,27867
In stock
+
RK-200N
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 211 kPa (1 kPa increments)
Pressure Unit:
bar
15,18359
In stock
+
RK-200N/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 211 kPa (1 kPa increments)
Pressure Unit:
bar
21,33016
In stock
+
RK-300-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 301 psi (1 psi increments)
Pressure Unit:
bar
22,23508
In stock
+
RK-300-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 301 psi (1 psi increments)
Pressure Unit:
bar
20,00070
In stock
+
RK-300-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 301 psi (1 psi increments)
Pressure Unit:
bar
20,89953
In stock
+
RK-300-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 301 psi (1 psi increments)
Pressure Unit:
bar
18,72609
In stock
+
RK-300
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 301 psi (1 psi increments)
Pressure Unit:
bar
19,63102
In stock
+
RK-300/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 301 psi (1 psi increments)
Pressure Unit:
bar
17,82422
In stock
+
RK-400N-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 411 kPa (1 kPa increments)
Pressure Unit:
bar
18,72914
In stock
+
RK-400N-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 411 kPa (1 kPa increments)
Pressure Unit:
bar
16,49477
In stock
+
RK-400N-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 411 kPa (1 kPa increments)
Pressure Unit:
bar
17,39359
In stock
+
RK-400N-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 411 kPa (1 kPa increments)
Pressure Unit:
bar
15,22016
In stock
+
RK-400N
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 411 kPa (1 kPa increments)
Pressure Unit:
bar
16,12508
In stock
+
RK-400N/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 411 kPa (1 kPa increments)
Pressure Unit:
bar
15,50250
In stock
+
RK-50-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 51 psi (1 psi increments)
Pressure Unit:
bar
16,40742
In stock
+
RK-50-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 51 psi (1 psi increments)
Pressure Unit:
bar
14,17305
In stock
+
RK-50-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 51 psi (1 psi increments)
Pressure Unit:
bar
15,07188
In stock
+
RK-50-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 51 psi (1 psi increments)
Pressure Unit:
bar
12,89844
In stock
+
RK-50
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 51 psi (1 psi increments)
Pressure Unit:
bar
13,80336
In stock
+
RK-50/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 51 psi (1 psi increments)
Pressure Unit:
bar
19,05211
In stock
+
RK-800N-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 811 kPa (1 kPa increments)
Pressure Unit:
bar
19,95703
In stock
+
RK-800N-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 811 kPa (1 kPa increments)
Pressure Unit:
bar
17,72266
In stock
+
RK-800N-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 811 kPa (1 kPa increments)
Pressure Unit:
bar
18,62148
In stock
+
RK-800N-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 811 kPa (1 kPa increments)
Pressure Unit:
bar

Features

  • Pressure Range: 0.145 to 300 psi or equivalent
  • Available pressure units: psi, kg/cm2, bar, kPa, inH2O, cmH2O, inHg
  • Accuracy: to ±0.05% of reading (±0.015 and 0.025% also available)
  • Repeatability: ±0.005% of reading
  • Local gravity calibration is available on all models
  • Floating Ball Operation
  • Self-Regulating
  • Interchangeable Weights
  • NIST Traceable

The floating ball Ametek RK pneumatic deadweight tester is engineered to offer user-friendly features, safe operation, and an optimal performance in the field or in the lab.

The Ametek RK pneumatic deadweight tester produces pressure by applying force (weight set) over area (the ceramic ball and nozzle). While in operation, the Ametek RK pneumatic deadweight tester's ball and weights float freely, supported only by a thin film of air which is virtually frictionless. This eliminates the necessity to rotate the weights during testing and allows the user to concentrate on the instrument calibration.

The Ametek RK pneumatic deadweight tester is self-regulating with accuracy independent of the operator. The built-in flow regulator automatically adjusts the input air flow to maintain the ball and weights in a float position. The regulator also compensates for variations in pressure from the air supply. These features of the Ametek RK pneumatic deadweight tester eliminate the necessity of having to continually adjust the supply during the test and provides for an easy up and down scale calibration.

The setup for the Ametek RK pneumatic deadweight tester is completed by simply connecting two tubes, one for the supply and one for the unit-under-test, leveling the RK, and adding the appropriate weights. Operation is fast and efficient with no valves to adjust and no regulation needed between set points. Pressure regulators are not required if the air supply is within the tester's operational requirements.

The Ametek RK pneumatic deadweight tester is NIST traceable and accurate to ±0.05% (optional accuracy up to ±0.015%) using stainless steel weights calibrated to International standard gravity at 9.80665 m/s2 or local gravity as specified. The Ametek RK pneumatic deadweight tester's test fluid is Nitrogen or instrument quality air complying with the ISA Standard S7.3. This fluid is non-contaminating to virtually all processes, thus eliminating the need to clean instruments after calibration and before use.

Ametek-RK-Datasheet (Ametek-RK-Datasheet.pdf, 231 Kb) [Download]

Ametek-RK-manual (Ametek-RK-manual.pdf, 4,128 Kb) [Download]