MBW Calibration 473 Dew Point Hygrometer SH2 measuring head, -20 to 70°C (-4 to 158°F) Three temperature inputs Without

105003+142612
$31,93580
In stock
+
Add to wish list
Delivery
Payment options
Our advantages
  • — 12 months warranty
  • — SMS notification
  • — Return and exchange
  • — Different payment methods
  • — Best price
Column filling
Sort by Price Sort by Availability Sort by CODE Sort by Measuring Head Sort by Additional Input/Output Options Sort by Barometric Pressure Option
$34,06000
In stock
+
105004+142612+100282
Measuring Head:
RP2 measuring head, -20 to 70°C (-4 to 158°F)
Additional Input/Output Options:
Three temperature inputs
Barometric Pressure Option:
Internal barometric pressure sensor, 0.1% accuracy
$31,93580
In stock
+
105004+142612
Measuring Head:
RP2 measuring head, -20 to 70°C (-4 to 158°F)
Additional Input/Output Options:
Three temperature inputs
Barometric Pressure Option:
Without
$32,55850
In stock
+
105004+102662+100282
Measuring Head:
RP2 measuring head, -20 to 70°C (-4 to 158°F)
Additional Input/Output Options:
Two Analog outputs -10 to 10V and 4 to 20mA
Barometric Pressure Option:
Internal barometric pressure sensor, 0.1% accuracy
$30,43430
In stock
+
105004+102662
Measuring Head:
RP2 measuring head, -20 to 70°C (-4 to 158°F)
Additional Input/Output Options:
Two Analog outputs -10 to 10V and 4 to 20mA
Barometric Pressure Option:
Without
$30,67870
In stock
+
105004+100282
Measuring Head:
RP2 measuring head, -20 to 70°C (-4 to 158°F)
Additional Input/Output Options:
Without
Barometric Pressure Option:
Internal barometric pressure sensor, 0.1% accuracy
$28,55450
In stock
+
105004
Measuring Head:
RP2 measuring head, -20 to 70°C (-4 to 158°F)
Additional Input/Output Options:
Without
Barometric Pressure Option:
Without
$34,06000
In stock
+
105003+142612+100282
Measuring Head:
SH2 measuring head, -20 to 70°C (-4 to 158°F)
Additional Input/Output Options:
Three temperature inputs
Barometric Pressure Option:
Internal barometric pressure sensor, 0.1% accuracy
$31,93580
In stock
+
105003+142612
Measuring Head:
SH2 measuring head, -20 to 70°C (-4 to 158°F)
Additional Input/Output Options:
Three temperature inputs
Barometric Pressure Option:
Without
$32,55850
In stock
+
105003+102662+100282
Measuring Head:
SH2 measuring head, -20 to 70°C (-4 to 158°F)
Additional Input/Output Options:
Two Analog outputs -10 to 10V and 4 to 20mA
Barometric Pressure Option:
Internal barometric pressure sensor, 0.1% accuracy
$30,43430
In stock
+
105003+102662
Measuring Head:
SH2 measuring head, -20 to 70°C (-4 to 158°F)
Additional Input/Output Options:
Two Analog outputs -10 to 10V and 4 to 20mA
Barometric Pressure Option:
Without
$30,67870
In stock
+
105003+100282
Measuring Head:
SH2 measuring head, -20 to 70°C (-4 to 158°F)
Additional Input/Output Options:
Without
Barometric Pressure Option:
Internal barometric pressure sensor, 0.1% accuracy
$28,55450
In stock
+
105003
Measuring Head:
SH2 measuring head, -20 to 70°C (-4 to 158°F)
Additional Input/Output Options:
Without
Barometric Pressure Option:
Without
$44,61990
In stock
+
141216+142612+100282
Measuring Head:
SHX measuring head, -30 to 99°C (-22 to 210°F)
Additional Input/Output Options:
Three temperature inputs
Barometric Pressure Option:
Internal barometric pressure sensor, 0.1% accuracy
$42,49570
In stock
+
141216+142612
Measuring Head:
SHX measuring head, -30 to 99°C (-22 to 210°F)
Additional Input/Output Options:
Three temperature inputs
Barometric Pressure Option:
Without
$43,11840
In stock
+
141216+102662+100282
Measuring Head:
SHX measuring head, -30 to 99°C (-22 to 210°F)
Additional Input/Output Options:
Two Analog outputs -10 to 10V and 4 to 20mA
Barometric Pressure Option:
Internal barometric pressure sensor, 0.1% accuracy
$40,99420
In stock
+
141216+102662
Measuring Head:
SHX measuring head, -30 to 99°C (-22 to 210°F)
Additional Input/Output Options:
Two Analog outputs -10 to 10V and 4 to 20mA
Barometric Pressure Option:
Without
$41,23860
In stock
+
141216+100282
Measuring Head:
SHX measuring head, -30 to 99°C (-22 to 210°F)
Additional Input/Output Options:
Without
Barometric Pressure Option:
Internal barometric pressure sensor, 0.1% accuracy
$39,11440
In stock
+
141216
Measuring Head:
SHX measuring head, -30 to 99°C (-22 to 210°F)
Additional Input/Output Options:
Without
Barometric Pressure Option:
Without

Features

  • Dew point range:
    • RP2: Direct insertion, -20 to 70°C (-4 to 158°F)
    • SH2: Flow-through, -20 to 70°C (-4 to 158°F)
    • SHX: Flow-through, -30 to 99 °C (-22 to 210.2°F)
  • Temperature range:
    • RP2 & SH2: -20 to 80°C (-4 to 176°F)
    • SHX: -50 to 125°C (-58 to 257°F)
  • Accuracy Dew point/Temperature
    • RP2: ≤ ±0.15°C/≤ ±0.07°C
    • SH2: ≤ ±0.1°C/≤ ±0.07°C
    • SHX: ≤ ±0.1°C/≤ ±0.07°C
  • Power Supply: 100-24VAC
  • Internal Barometric Pressure Sensor, 700 to 1200mbar (optional)
  • 0.1% or 0.01% accuracy, 700 to 1200mbar
  • Two user programmable analog outputs
    • -10 to 10V
    • 4 to 20mA
  • RS-232 digital I/O
  • Suitable for use as a transfer standard
  • 5 points FP/DP, 3 points temp. factory calibration certificate
  • Pelican 1550 foam lined transport case

The MBW Calibration 473 dew point hygrometer features cable mounted measuring heads that allow the user to measure directly within the application environment, and includes a temperature probe as standard. The 473 is able to calculate, display and output relative humidity.

MBW chilled mirror hygrometers provide precise, stable and repeatable measurement results. The 473 utilizes high quality materials and precision engineering have a service life of more than 15 years. The platinum resistance thermometer (PRT) element that is embedded within the mirror ensures measurement stability over a long period of time.

MBW's ForceFrost™ function over-cools the mirror to force the condensed layer to the solid phase when the temperature falls below a user defined limit. This eliminates the uncertainty of whether dew or frost point is measured.

Three different measuring heads with 2m connecting cables are available.

SH2 Measuring Head

Flow-through dew point measuring head with a 2-stage Peltier element for mirror temperature control. Includes a calibrated temperature probe for connecting to either the measuring head or the back panel of the 473. The included variable speed fan pulls a consistent airflow across the mirror. With the fan removed, the user can also connect the SH2 to applications using tubing and standard 6mm or 1/4in fittings.

RP2 Measuring Head

A 2-stage Peltier element in a compact probe that includes a connection for temperature measurement. It is supplied with a calibrated head mounted temperature probe and an extension cable to enable optimum placement for your application.

SHX Measuring Head

Chilled mirror dew point head designed for high temperature applications. It incorporates a sample fan with controllable speed to maintain stable and precise flow within the recommended range of 0.3 to 1lpm at atmospheric pressure. A high temperature motor is combined with an aluminum impeller/cowl to maintain a reliable and stable sample flow. The flow rate can be changed through serial commands that are entered via the front panel of the 473.

MBW_473_Datasheet_EN (MBW_473_Datasheet_EN.pdf, 1,663 Kb) [Download]

MBW_473-SHX_Datasheet_EN (MBW_473-SHX_Datasheet_EN.pdf, 1,608 Kb) [Download]

MBW473_Manual_EN (MBW473_Manual_EN.pdf, 3,851 Kb) [Download]

You may be interested
  • Most Popular
  • On Sale
  • Recently Viewed
 
Fast and high quality delivery

Our company makes delivery all over the country

Quality assurance and service

We offer only those goods, in which quality we are sure

Returns within 30 days

You have 30 days to test your purchase