Capteur de gaz ammoniac Manning Systems EC-FX-NH3 0 to 200 ppm With ATMOS technology With LCD display Stainless steel enclosure

ECFX-200-ALS
$2,03060
En stock
Delivery
Payment options
Our advantages
  • — 12 months warranty
  • — SMS notification
  • — Return and exchange
  • — Different payment methods
  • — Best price
Column filling
Trier par Prix Trier par Disponibilité Trier par Réf. Trier par Enceinte Trier par Écran LCD Trier par Plage de PPM Trier par Technologie ATMOS
$2,00460
En stock
+
ECFX-100-N
Enceinte:
NEMA 1 enclosure
Écran LCD:
No
Plage de PPM:
0 to 100 ppm
Technologie ATMOS:
No
$2,00460
En stock
+
ECFX-100-S
Enceinte:
Stainless steel enclosure
Écran LCD:
No
Plage de PPM:
0 to 100 ppm
Technologie ATMOS:
No
$2,00460
En stock
+
ECFX-100-LN
Enceinte:
NEMA 1 enclosure
Écran LCD:
With LCD display
Plage de PPM:
0 to 100 ppm
Technologie ATMOS:
No
$2,00460
En stock
+
ECFX-100-LS
Enceinte:
Stainless steel enclosure
Écran LCD:
With LCD display
Plage de PPM:
0 to 100 ppm
Technologie ATMOS:
No
$2,00460
En stock
+
ECFX-100-AN
Enceinte:
NEMA 1 enclosure
Écran LCD:
No
Plage de PPM:
0 to 100 ppm
Technologie ATMOS:
With ATMOS technology
$2,00460
En stock
+
ECFX-100-AS
Enceinte:
Stainless steel enclosure
Écran LCD:
No
Plage de PPM:
0 to 100 ppm
Technologie ATMOS:
With ATMOS technology
$2,00460
En stock
+
ECFX-100-ALN
Enceinte:
NEMA 1 enclosure
Écran LCD:
With LCD display
Plage de PPM:
0 to 100 ppm
Technologie ATMOS:
With ATMOS technology
$2,00460
En stock
+
ECFX-100-ALS
Enceinte:
Stainless steel enclosure
Écran LCD:
With LCD display
Plage de PPM:
0 to 100 ppm
Technologie ATMOS:
With ATMOS technology
$2,27240
En stock
+
ECFX-1000-N
Enceinte:
NEMA 1 enclosure
Écran LCD:
No
Plage de PPM:
0 to 1000 ppm
Technologie ATMOS:
No
$2,27240
En stock
+
ECFX-1000-S
Enceinte:
Stainless steel enclosure
Écran LCD:
No
Plage de PPM:
0 to 1000 ppm
Technologie ATMOS:
No
$2,27240
En stock
+
ECFX-1000-LN
Enceinte:
NEMA 1 enclosure
Écran LCD:
With LCD display
Plage de PPM:
0 to 1000 ppm
Technologie ATMOS:
No
$2,27240
En stock
+
ECFX-1000-LS
Enceinte:
Stainless steel enclosure
Écran LCD:
With LCD display
Plage de PPM:
0 to 1000 ppm
Technologie ATMOS:
No
$2,27240
En stock
+
ECFX-1000-AN
Enceinte:
NEMA 1 enclosure
Écran LCD:
No
Plage de PPM:
0 to 1000 ppm
Technologie ATMOS:
With ATMOS technology
$2,27240
En stock
+
ECFX-1000-AS
Enceinte:
Stainless steel enclosure
Écran LCD:
No
Plage de PPM:
0 to 1000 ppm
Technologie ATMOS:
With ATMOS technology
$2,27240
En stock
+
ECFX-1000-ALN
Enceinte:
NEMA 1 enclosure
Écran LCD:
With LCD display
Plage de PPM:
0 to 1000 ppm
Technologie ATMOS:
With ATMOS technology
$2,27240
En stock
+
ECFX-1000-ALS
Enceinte:
Stainless steel enclosure
Écran LCD:
With LCD display
Plage de PPM:
0 to 1000 ppm
Technologie ATMOS:
With ATMOS technology
$2,03060
En stock
+
ECFX-200-N
Enceinte:
NEMA 1 enclosure
Écran LCD:
No
Plage de PPM:
0 to 200 ppm
Technologie ATMOS:
No
$2,03060
En stock
+
ECFX-200-S
Enceinte:
Stainless steel enclosure
Écran LCD:
No
Plage de PPM:
0 to 200 ppm
Technologie ATMOS:
No
$2,03060
En stock
+
ECFX-200-LN
Enceinte:
NEMA 1 enclosure
Écran LCD:
With LCD display
Plage de PPM:
0 to 200 ppm
Technologie ATMOS:
No
$2,03060
En stock
+
ECFX-200-LS
Enceinte:
Stainless steel enclosure
Écran LCD:
With LCD display
Plage de PPM:
0 to 200 ppm
Technologie ATMOS:
No
$2,03060
En stock
+
ECFX-200-AN
Enceinte:
NEMA 1 enclosure
Écran LCD:
No
Plage de PPM:
0 to 200 ppm
Technologie ATMOS:
With ATMOS technology
$2,03060
En stock
+
ECFX-200-AS
Enceinte:
Stainless steel enclosure
Écran LCD:
No
Plage de PPM:
0 to 200 ppm
Technologie ATMOS:
With ATMOS technology
$2,03060
En stock
+
ECFX-200-ALN
Enceinte:
NEMA 1 enclosure
Écran LCD:
With LCD display
Plage de PPM:
0 to 200 ppm
Technologie ATMOS:
With ATMOS technology
$2,03060
En stock
+
ECFX-200-ALS
Enceinte:
Stainless steel enclosure
Écran LCD:
With LCD display
Plage de PPM:
0 to 200 ppm
Technologie ATMOS:
With ATMOS technology
$2,03060
En stock
+
ECFX-250-N
Enceinte:
NEMA 1 enclosure
Écran LCD:
No
Plage de PPM:
0 to 250 ppm
Technologie ATMOS:
No
$2,03060
En stock
+
ECFX-250-S
Enceinte:
Stainless steel enclosure
Écran LCD:
No
Plage de PPM:
0 to 250 ppm
Technologie ATMOS:
No
$2,03060
En stock
+
ECFX-250-LN
Enceinte:
NEMA 1 enclosure
Écran LCD:
With LCD display
Plage de PPM:
0 to 250 ppm
Technologie ATMOS:
No
$2,03060
En stock
+
ECFX-250-LS
Enceinte:
Stainless steel enclosure
Écran LCD:
With LCD display
Plage de PPM:
0 to 250 ppm
Technologie ATMOS:
No
$2,03060
En stock
+
ECFX-250-AN
Enceinte:
NEMA 1 enclosure
Écran LCD:
No
Plage de PPM:
0 to 250 ppm
Technologie ATMOS:
With ATMOS technology
$2,03060
En stock
+
ECFX-250-AS
Enceinte:
Stainless steel enclosure
Écran LCD:
No
Plage de PPM:
0 to 250 ppm
Technologie ATMOS:
With ATMOS technology
$2,03060
En stock
+
ECFX-250-ALN
Enceinte:
NEMA 1 enclosure
Écran LCD:
With LCD display
Plage de PPM:
0 to 250 ppm
Technologie ATMOS:
With ATMOS technology
$2,03060
En stock
+
ECFX-250-ALS
Enceinte:
Stainless steel enclosure
Écran LCD:
With LCD display
Plage de PPM:
0 to 250 ppm
Technologie ATMOS:
With ATMOS technology
$2,18920
En stock
+
ECFX-500-N
Enceinte:
NEMA 1 enclosure
Écran LCD:
No
Plage de PPM:
0 to 500 ppm
Technologie ATMOS:
No
$2,18920
En stock
+
ECFX-500-S
Enceinte:
Stainless steel enclosure
Écran LCD:
No
Plage de PPM:
0 to 500 ppm
Technologie ATMOS:
No
$2,18920
En stock
+
ECFX-500-LN
Enceinte:
NEMA 1 enclosure
Écran LCD:
With LCD display
Plage de PPM:
0 to 500 ppm
Technologie ATMOS:
No
$2,18920
En stock
+
ECFX-500-LS
Enceinte:
Stainless steel enclosure
Écran LCD:
With LCD display
Plage de PPM:
0 to 500 ppm
Technologie ATMOS:
No
$2,18920
En stock
+
ECFX-500-AN
Enceinte:
NEMA 1 enclosure
Écran LCD:
No
Plage de PPM:
0 to 500 ppm
Technologie ATMOS:
With ATMOS technology
$2,18920
En stock
+
ECFX-500-AS
Enceinte:
Stainless steel enclosure
Écran LCD:
No
Plage de PPM:
0 to 500 ppm
Technologie ATMOS:
With ATMOS technology
$2,18920
En stock
+
ECFX-500-ALN
Enceinte:
NEMA 1 enclosure
Écran LCD:
With LCD display
Plage de PPM:
0 to 500 ppm
Technologie ATMOS:
With ATMOS technology
$2,18920
En stock
+
ECFX-500-ALS
Enceinte:
Stainless steel enclosure
Écran LCD:
With LCD display
Plage de PPM:
0 to 500 ppm
Technologie ATMOS:
With ATMOS technology

Caractéristiques

  • Plages de mesure jusqu'à 1000 ppm de NH3
  • Précision de ±5 % à pleine échelle
  • Répétabilité de <10 % à pleine échelle
  • Boîtier NEMA 1 (PPO) ou robuste en acier inoxydable
  • Construction robuste pour une fiabilité à long terme
  • Technologie ATMOS en option
    • Adapte automatiquement le détecteur à son environnement
    • Peut fonctionner à -50 °F et 100 % d'humidité
  • Technologie SensorCheck
    • Vérifie la viabilité électrique du capteur toutes les 24 heures
  • Écran LCD en option pour une visibilité en temps réel
  • 3 électrodes Capteur électrochimique
  • Garantie de 3 ans

Le capteur d'ammoniac Manning EC-FX-NH3 est la prochaine étape dans l'évolution de la technologie de détection éprouvée de Manning Systems. Conçu pour les applications de réfrigération industrielle, l'EC-FX-NH3 offre la fiabilité, la précision, la robustesse et les performances durables pour gérer les conditions extrêmes mieux que n'importe lequel de ses concurrents.

Si vous utilisez de l'ammoniac dans le cadre de votre processus de réfrigération, vous êtes confronté à plusieurs défis pour protéger votre usine du danger et des dépenses liées aux fuites d'ammoniac. Le Manning EC-FX-NH3 est doté d'un tout nouveau capteur d'ammoniac avec un électrolyte exclusif qui résiste aux environnements difficiles. Que vous surveilliez l'ammoniac dans des congélateurs à air pulsé, des entrepôts frigorifiques ou des salles des machines, vous pouvez avoir confiance dans l'efficacité de votre système de détection de gaz, qui vous aide à garantir la sécurité des personnes, à prévenir la détérioration des aliments et à gérer les coûts.

Contrairement à d'autres capteurs d'ammoniac, le capteur EC-FX-NH3 conserve sa sensibilité même lors de changements rapides de température et d'humidité. Alors que d'autres capteurs peuvent rapidement perdre leur sensibilité après une exposition au gaz ammoniac, le capteur EC-FX-NH3 rebondit après une exposition au gaz au niveau d'alarme et reprend une détection précise.

Le capteur EC‑FX‑NH3 s'adapte automatiquement à son environnement et peut fonctionner à -50 °F et 100 % d'humidité. Il est également équipé de SensorCheck, un microprocesseur qui vérifie la viabilité électrique du capteur toutes les 24 heures afin que vous puissiez être sûr que le capteur fonctionne correctement.

Le capteur d'ammoniac Manning EC-FX-NH3 est si bien construit et si riche en fonctionnalités qu'il dure, en moyenne, 18 mois de plus que les autres capteurs. Passer maintenant à EC-FX-NH3 peut vous faire économiser des milliers de dollars.

EC-FX-NH3-datasheet (EC-FX-NH3-datasheet.pdf, 131 Kb) [Télécharger]

EC-FX-datasheet (EC-FX-datasheet.pdf, 115 Kb) [Télécharger]

EC-FX-NH3-brochure (EC-FX-NH3-brochure.pdf, 1,086 Kb) [Télécharger]

ECFXNH3-manual (ECFXNH3-manual.pdf, 1,671 Kb) [Télécharger]

EC-FX-Calibration-Procedure (EC-FX-Calibration-Procedure.pdf, 72 Kb) [Télécharger]

Honeywell_ammoniasensor_WhitePaper (Honeywell_ammoniasensor_WhitePaper.pdf, 3,587 Kb) [Télécharger]

Honeywell-ECFX-brochure (Honeywell-ECFX-brochure.pdf, 1,193 Kb) [Télécharger]

Honeywell-Gas-Detection-Bump-Test-and-Calibration-Frequency (Honeywell-Gas-Detection-Bump-Test-and-Calibration-Frequency.pdf, 70 Kb) [Télécharger]

You may be interested
  • Most Popular
  • On Sale
  • Recently Viewed
 
Fast and high quality delivery

Our company makes delivery all over the country

Quality assurance and service

We offer only those goods, in which quality we are sure

Returns within 30 days

You have 30 days to test your purchase