MTL 5500 Intrinsically Safe Isolators Analog output With FSM certification 2-channel smart 4-20mA output + LFD

MTL554949
£55734
In stock
+
Add to wish list
Delivery
Payment options
Our advantages
  • — 12 months warranty
  • — SMS notification
  • — Return and exchange
  • — Different payment methods
  • — Best price
Column filling
Sort by Price Sort by Availability Sort by CODE Sort by Model Sort by Function Sort by Functional Safety Management Certification
£35404
In stock
+
MTL554141
Model:
1-channel smart transmitter repeater 4-20mA
Function:
Analog input
Functional Safety Management Certification:
With FSM certification
£38032
In stock
+
MTL5541S41S
Model:
1-channel smart transmitter repeater 4-20mA, sink o/p
Function:
Analog input
Functional Safety Management Certification:
With FSM certification
£52968
In stock
+
MTL5544D44D
Model:
1-channel smart transmitter repeater, dual o/p
Function:
Analog input
Functional Safety Management Certification:
With FSM certification
£61888
In stock
+
MTL554444
Model:
2-channel smart transmitter repeater 4-20mA
Function:
Analog input
Functional Safety Management Certification:
With FSM certification
£61957
In stock
+
MTL5544S44S
Model:
2-channel smart transmitter repeater 4-20mA, sink o/p
Function:
Analog input
Functional Safety Management Certification:
With FSM certification
£41074
In stock
+
MTL5541A41A
Model:
1-channel smart 4-wire transmitter repeater
Function:
Analog input
Functional Safety Management Certification:
Without FSM certification
£41697
In stock
+
MTL5541AS41AS
Model:
1-channel smart 4-wire transmitter repeater, sink o/p
Function:
Analog input
Functional Safety Management Certification:
Without FSM certification
£63617
In stock
+
MTL5544A44A
Model:
2-channel smart 4-wire transmitter repeater
Function:
Analog input
Functional Safety Management Certification:
Without FSM certification
£63617
In stock
+
MTL5544AS44AS
Model:
2-channel smart 4-wire transmitter repeater, sink o/p
Function:
Analog input
Functional Safety Management Certification:
Without FSM certification
£42872
In stock
+
MTL554646
Model:
1-channel smart 4-20mA output + LFD
Function:
Analog output
Functional Safety Management Certification:
With FSM certification
£42872
In stock
+
MTL5546Y46Y
Model:
1-channel smart 4-20mA output + o/c LFD
Function:
Analog output
Functional Safety Management Certification:
With FSM certification
£55734
In stock
+
MTL554949
Model:
2-channel smart 4-20mA output + LFD
Function:
Analog output
Functional Safety Management Certification:
With FSM certification
£55734
In stock
+
MTL5549Y49Y
Model:
2-channel smart 4-20mA output + o/c LFD
Function:
Analog output
Functional Safety Management Certification:
With FSM certification
£22612
In stock
+
MTL551111
Model:
1-channel DI c/o relay output + LFD
Function:
Digital input
Functional Safety Management Certification:
With FSM certification
£29181
In stock
+
MTL551414
Model:
1-channel DI relay output + LFD alarm
Function:
Digital input
Functional Safety Management Certification:
With FSM certification
£29596
In stock
+
MTL5514D14D
Model:
1-channel DI relay output with repeat
Function:
Digital input
Functional Safety Management Certification:
With FSM certification
£51862
In stock
+
MTL5501-SR01-SR
Model:
1-channel safety input SIL3
Function:
Digital input
Functional Safety Management Certification:
With FSM certification
£29181
In stock
+
MTL5516C16C
Model:
2-channel DI c/o relay output + LFD
Function:
Digital input
Functional Safety Management Certification:
With FSM certification
£35266
In stock
+
MTL551717
Model:
2-channel DI relay output + LFD alarm
Function:
Digital input
Functional Safety Management Certification:
With FSM certification
£29181
In stock
+
MTL551313
Model:
2-channel DI solid state output + LFD
Function:
Digital input
Functional Safety Management Certification:
Without FSM certification
£48059
In stock
+
MTL551010
Model:
4-channel digital input
Function:
Digital input
Functional Safety Management Certification:
Without FSM certification
£59952
In stock
+
MTL5510B10B
Model:
4-channel multifunction digital input
Function:
Digital input
Functional Safety Management Certification:
Without FSM certification
£25793
In stock
+
MTL552121
Model:
Loop powered solenoid driver, 25V, 147mA
Function:
Digital output
Functional Safety Management Certification:
With FSM certification
£28489
In stock
+
MTL552222
Model:
Loop powered solenoid driver, IIB
Function:
Digital output
Functional Safety Management Certification:
With FSM certification
£35543
In stock
+
MTL552323
Model:
Solenoid driver + LFD, 25V, 147mA
Function:
Digital output
Functional Safety Management Certification:
With FSM certification
£31532
In stock
+
MTL552424
Model:
Solenoid driver, switch control + OVR, 25V, 147mA
Function:
Digital output
Functional Safety Management Certification:
With FSM certification
£27176
In stock
+
MTL552525
Model:
Solenoid driver, switch control + OVR, 25V, 83.3mA
Function:
Digital output
Functional Safety Management Certification:
With FSM certification
£35543
In stock
+
MTL5523VL23VL
Model:
Solenoid driver,voltage control + LFD, 25V, 108mA
Function:
Digital output
Functional Safety Management Certification:
With FSM certification
£35543
In stock
+
MTL5523V23V
Model:
Solenoid driver,voltage control + LFD, 25V, 147mA
Function:
Digital output
Functional Safety Management Certification:
With FSM certification
£29319
In stock
+
MTL552626
Model:
2-channel loop powered/switched IS relay
Function:
Digital output
Functional Safety Management Certification:
Without FSM certification
£41628
In stock
+
MTL556161
Model:
2-channel fire/smoke detector interface
Function:
Fire and Smoke
Functional Safety Management Certification:
With FSM certification
£46814
In stock
+
MTL553232
Model:
1-channel pulse isolator, converter with trip
Function:
Pulse and vibration
Functional Safety Management Certification:
Without FSM certification
£49718
In stock
+
MTL553131
Model:
1-channel vibration transducer interface
Function:
Pulse and vibration
Functional Safety Management Certification:
Without FSM certification
£43495
In stock
+
MTL558181
Model:
1-channel mV isolator
Function:
Temperature input
Functional Safety Management Certification:
Without FSM certification
£63963
In stock
+
MTL558282
Model:
1-channel RTD isolator
Function:
Temperature input
Functional Safety Management Certification:
Without FSM certification
£49234
In stock
+
MTL557373
Model:
1-channel temperature converter
Function:
Temperature input
Functional Safety Management Certification:
Without FSM certification
£56426
In stock
+
MTL557575
Model:
1-channel temperature converter + alarm
Function:
Temperature input
Functional Safety Management Certification:
Without FSM certification
£77032
In stock
+
MTL5576-RTD76-RTD
Model:
2-channel temperature converter, RTD
Function:
Temperature input
Functional Safety Management Certification:
Without FSM certification
£77032
In stock
+
MTL5576-THC76-THC
Model:
2-channel temperature converter, thermocouple
Function:
Temperature input
Functional Safety Management Certification:
Without FSM certification

Features

  • 3-port isolation as standard
  • Highest module/channel packing densities
  • Low power dissipation
  • Quick install and release mechanism
  • Multi-channel I/O modules
  • Broken line and earth-fault protection
  • Compatible with preceding MTL isolator series for pluggable replacements
  • Various models assessed for use in Functional Safety applications

The MTL5500 series intrinsically safe isolators are DIN rail mounted, high efficiency isolating interfaces with system vendors in mind. The MTL5500 series is the latest generation of IS interfaces which utilize an innovative "One-Core" technology to ensure the highest quality and availability while maintaining maximum flexibility at lowest cost. Incorporating advanced circuit design, a common set of components and innovative isolating transformer construction, they achieve a significant reduction in power consumption while increasing channel packing densities.

The DIN-rail mounting MTL5500 Series meets the needs of the IS interface market for "application focused" projects, ranging from single instrument loops, through to fully equipped cabinets, across all industries where hazardous areas exist.

The MTL5500 clips quickly onto DIN rail, so it is compatible with the industry-standard mounting system. Wiring is simplified by plugin safe- and hazardous-area connectors, and a power plug which accepts a power bus; it all leads to quicker insertion, fewer wiring errors and trouble-free, tidier installations.

Status LEDs, configuration switches and ports are located on the top or side of individual MTL5500 modules, as appropriate, for easy access. In addition to their use in IS circuits, specific MTL5500 models have been assessed and approved for use in Functional Safety applications. These have been verified under the certified Functional Safety Management (FSM) program implemented by MT

crouse-hinds-mtl4500-range-intrinsically-safety-galvanic-isolators-datasheet (crouse-hinds-mtl4500-range-intrinsically-safety-galvanic-isolators-datasheet.pdf, 3,399 Kb) [Download]

crouse-hinds-mtl5500-range-isolating-interface-units-manual (crouse-hinds-mtl5500-range-isolating-interface-units-manual.pdf, 3,496 Kb) [Download]

MTL-5500-ATEXmanual (MTL-5500-ATEXmanual.pdf, 501 Kb) [Download]