APG Kari Level Switch S series, standard size (6.1" H x 6.7" W) Low Alarm 15 meters Standard 130°F (55°C)

KA-1L15
£5670
In stock
+
Add to wish list
Delivery
Payment options
Our advantages
  • — 12 months warranty
  • — SMS notification
  • — Return and exchange
  • — Different payment methods
  • — Best price
Column filling
Sort by Price Sort by Availability Sort by CODE Sort by Cable Length Sort by Temperature Sort by Series Sort by Model and Function
£21989
In stock
+
KA-1HE15-K
Cable Length:
15 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Dual High Alarm
£14106
In stock
+
KA-1HE15
Cable Length:
15 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Dual High Alarm
£21989
In stock
+
KA-1HE-K
Cable Length:
5 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Dual High Alarm
£14106
In stock
+
KA-1HE
Cable Length:
5 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Dual High Alarm
£21989
In stock
+
KA-1LE15-K
Cable Length:
15 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Dual Low Alarm
£14106
In stock
+
KA-1LE15
Cable Length:
15 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Dual Low Alarm
£21989
In stock
+
KA-1LE-K
Cable Length:
5 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Dual Low Alarm
£14106
In stock
+
KA-1LE
Cable Length:
5 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Dual Low Alarm
£33537
In stock
+
KA-4H5E15-K
Cable Length:
15 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Duplex Pump Empty + Isolated High Alarm
£25654
In stock
+
KA-4H5E15
Cable Length:
15 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Duplex Pump Empty + Isolated High Alarm
£33537
In stock
+
KA-4H5E-K
Cable Length:
5 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Duplex Pump Empty + Isolated High Alarm
£25654
In stock
+
KA-4H5E
Cable Length:
5 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Duplex Pump Empty + Isolated High Alarm
£33537
In stock
+
KA-4L5E15-K
Cable Length:
15 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Duplex Pump Fill + Isolated Low Alarm
£25654
In stock
+
KA-4L5E15
Cable Length:
15 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Duplex Pump Fill + Isolated Low Alarm
£33537
In stock
+
KA-4L5E-K
Cable Length:
5 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Duplex Pump Fill + Isolated Low Alarm
£25654
In stock
+
KA-4L5E
Cable Length:
5 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Duplex Pump Fill + Isolated Low Alarm
£17356
In stock
+
KA-1C15-K
Cable Length:
15 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
High / Low Alarm
£9473
In stock
+
KA-1C15
Cable Length:
15 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
High / Low Alarm
£17356
In stock
+
KA-1C-K
Cable Length:
5 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
High / Low Alarm
£9473
In stock
+
KA-1C
Cable Length:
5 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
High / Low Alarm
£13553
In stock
+
KA-1H15-K
Cable Length:
15 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
High Alarm
£5670
In stock
+
KA-1H15
Cable Length:
15 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
High Alarm
£13553
In stock
+
KA-1H-K
Cable Length:
5 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
High Alarm
£5670
In stock
+
KA-1H
Cable Length:
5 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
High Alarm
£21644
In stock
+
KA-2HL15-K
Cable Length:
15 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
High and Low Alarm
£13761
In stock
+
KA-2HL15
Cable Length:
15 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
High and Low Alarm
£21644
In stock
+
KA-2HL-K
Cable Length:
5 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
High and Low Alarm
£13761
In stock
+
KA-2HL
Cable Length:
5 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
High and Low Alarm
£22957
In stock
+
KA-3H15-K
Cable Length:
15 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Empty + High Alarm
£15074
In stock
+
KA-3H15
Cable Length:
15 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Empty + High Alarm
£22957
In stock
+
KA-3H-K
Cable Length:
5 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Empty + High Alarm
£15074
In stock
+
KA-3H
Cable Length:
5 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Empty + High Alarm
£27590
In stock
+
KA-4H15-K
Cable Length:
15 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Empty + High and Low Alarm (4 conductor)
£19707
In stock
+
KA-4H15
Cable Length:
15 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Empty + High and Low Alarm (4 conductor)
£27590
In stock
+
KA-4H-K
Cable Length:
5 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Empty + High and Low Alarm (4 conductor)
£19707
In stock
+
KA-4H
Cable Length:
5 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Empty + High and Low Alarm (4 conductor)
£24894
In stock
+
KA-3HE15-K
Cable Length:
15 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Empty + Isolated High Alarm
£17011
In stock
+
KA-3HE15
Cable Length:
15 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Empty + Isolated High Alarm
£24894
In stock
+
KA-3HE-K
Cable Length:
5 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Empty + Isolated High Alarm
£17011
In stock
+
KA-3HE
Cable Length:
5 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Empty + Isolated High Alarm
£16734
In stock
+
KA-2H15-K
Cable Length:
15 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Empty Control (Pump Down)
£8851
In stock
+
KA-2H15
Cable Length:
15 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Empty Control (Pump Down)
£16734
In stock
+
KA-2H-K
Cable Length:
5 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Empty Control (Pump Down)
£8851
In stock
+
KA-2H
Cable Length:
5 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Empty Control (Pump Down)
£27590
In stock
+
KA-4L15-K
Cable Length:
15 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Fill + High and Low Alarm (4 conductor)
£19707
In stock
+
KA-4L15
Cable Length:
15 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Fill + High and Low Alarm (4 conductor)
£27590
In stock
+
KA-4L-K
Cable Length:
5 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Fill + High and Low Alarm (4 conductor)
£19707
In stock
+
KA-4L
Cable Length:
5 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Fill + High and Low Alarm (4 conductor)
£22335
In stock
+
KA-3LE15-K
Cable Length:
15 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Fill + Isolated Low Alarm
£14452
In stock
+
KA-3LE15
Cable Length:
15 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Fill + Isolated Low Alarm
£22335
In stock
+
KA-3LE-K
Cable Length:
5 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Fill + Isolated Low Alarm
£14452
In stock
+
KA-3LE
Cable Length:
5 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Fill + Isolated Low Alarm
£22957
In stock
+
KA-3L15-K
Cable Length:
15 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Fill + Low Alarm
£15074
In stock
+
KA-3L15
Cable Length:
15 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Fill + Low Alarm
£22957
In stock
+
KA-3L-K
Cable Length:
5 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Fill + Low Alarm
£15074
In stock
+
KA-3L
Cable Length:
5 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Fill + Low Alarm
£16734
In stock
+
KA-2L15-K
Cable Length:
15 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Fill Control (Pump Up)
£8851
In stock
+
KA-2L15
Cable Length:
15 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Fill Control (Pump Up)
£16734
In stock
+
KA-2L-K
Cable Length:
5 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Fill Control (Pump Up)
£8851
In stock
+
KA-2L
Cable Length:
5 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Hysteresis Fill Control (Pump Up)
£28489
In stock
+
KA-4Y3915-K
Cable Length:
15 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Lead/Lag Pump Control + High and Low Alarm
£20606
In stock
+
KA-4Y3915
Cable Length:
15 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Lead/Lag Pump Control + High and Low Alarm
£28489
In stock
+
KA-4Y39-K
Cable Length:
5 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Lead/Lag Pump Control + High and Low Alarm
£20606
In stock
+
KA-4Y39
Cable Length:
5 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Lead/Lag Pump Control + High and Low Alarm
£13553
In stock
+
KA-1L15-K
Cable Length:
15 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Low Alarm
£5670
In stock
+
KA-1L15
Cable Length:
15 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Low Alarm
£13553
In stock
+
KA-1L-K
Cable Length:
5 meters
Temperature :
High Temperature 175°F (80°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Low Alarm
£5670
In stock
+
KA-1L
Cable Length:
5 meters
Temperature :
Standard 130°F (55°C)
Series:
S series, standard size (6.1" H x 6.7" W)
Model and Function:
Low Alarm

Features

  • Switching differential
    • Minimum 10 in.
    • Maximum 50 in.
  • Maximum Pressure: 28 psi (2 bar)
  • Up to 4 switching levels
  • Optional built-in hysteresis
  • Minimum fluid specific gravity:
    • 0.7 for Standard float
    • 0.95 for Mini float
  • Mercury and lead free
  • High chemical compatibility
  • Proven reliability in operation
  • Max Voltage: 250 VAC or DC
  • Temperature: 130°F, high temperature option up to 175°F
  • Float Material: Polypropylene
  • Cable material: PVC (standard); Polypropylene, Rubber, Teflon® available by request
  • Standard cable length: 5m (16 ft), 15m (49 ft.) available
  • Housing rated IP67, NEMA 6
  • Certifications: CE, CSA General Purpose

The APG Kari level switch is a cable suspended float level switch allows up to 4 switch points in a single float. The Kari can replace four single-level float switches. It can accomplish the same functionality with only one float, saving you money, avoiding tangles, and getting the job done. While the Kari float switch can be used in a myriad applications, it's extremely well suited for lift stations.

Kari float switches come purpose built for a variety of unique applications with many different configurations. Unlike any other float switch on the market, several models include built-in hysteresis. The float handles the logic all by itself - making them ideal for backup pump control applications and reducing the need for expensive controllers.

The APG Kari is simple to set up and use. The different activation levels within the float are easy to adjust by lengthening the cable and moving the weight. The closer the weight to the float, the tighter the switching differential - or the closer the switching levels are to each other. If you can wire a simple switch, then you can achieve complex pump control behavior with a single Kari float switch.

The Kari float switch features a high chemical compatibility, a stronger cable, and durable components that simply last longer than the competition. They also use no lead or mercury.

APG-Kari-datasheet (APG-Kari-datasheet.pdf, 821 Kb) [Download]

APG-Kari-manual (APG-Kari-manual.pdf, 440 Kb) [Download]

Level-Application-Information-Form (Level-Application-Information-Form.pdf, 141 Kb) [Download]

You may be interested
  • Most Popular
  • On Sale
  • Recently Viewed
 
Fast and high quality delivery

Our company makes delivery all over the country

Quality assurance and service

We offer only those goods, in which quality we are sure

Returns within 30 days

You have 30 days to test your purchase