Michell Instruments Pura Pure Gas Dew Point Transmitter 2-wire, 4-20mA with M12 connector Clean room cleaned, inert gas-filled, double bagged and sealed, 1/4” VCR Non-standard measurement range

PUR-TX-2W-M12-PRM-(v/wx-yz)
$16,53991
In stock
+
Add to wish list
Delivery
Payment options
Our advantages
  • — 12 months warranty
  • — SMS notification
  • — Return and exchange
  • — Different payment methods
  • — Best price
Column filling
Sort by Price Sort by Availability Sort by CODE Sort by Range Sort by Configuration Sort by Electrical Options
$15,79802
In stock
+
PUR-TX-2W-PRM-(-120/-40)
Range:
-184 to -40°F (-120 to -40°C) dp range
Configuration:
Clean room cleaned, inert gas-filled, double bagged and sealed, 1/4” VCR
Electrical Options:
2-wire, 4-20mA
$16,07441
In stock
+
PUR-TX-2W-PRM-(v/wx-yz)
Range:
Non-standard measurement range
Configuration:
Clean room cleaned, inert gas-filled, double bagged and sealed, 1/4” VCR
Electrical Options:
2-wire, 4-20mA
$14,52516
In stock
+
PUR-TX-2W-OEM-(-120/-40)
Range:
-184 to -40°F (-120 to -40°C) dp range
Configuration:
Clean room cleaned, single bagged and sealed, 1/4" VCR
Electrical Options:
2-wire, 4-20mA
$14,80155
In stock
+
PUR-TX-2W-OEM-(v/wx-yz)
Range:
Non-standard measurement range
Configuration:
Clean room cleaned, single bagged and sealed, 1/4" VCR
Electrical Options:
2-wire, 4-20mA
$18,11827
In stock
+
PUR-IS-2W-PRM-(-120/-40)
Range:
-184 to -40°F (-120 to -40°C) dp range
Configuration:
Clean room cleaned, inert gas-filled, double bagged and sealed, 1/4” VCR
Electrical Options:
2-wire, 4-20mA for hazardous areas
$18,39466
In stock
+
PUR-IS-2W-PRM-(v/wx-yz)
Range:
Non-standard measurement range
Configuration:
Clean room cleaned, inert gas-filled, double bagged and sealed, 1/4” VCR
Electrical Options:
2-wire, 4-20mA for hazardous areas
$16,84541
In stock
+
PUR-IS-2W-OEM-(-120/-40)
Range:
-184 to -40°F (-120 to -40°C) dp range
Configuration:
Clean room cleaned, single bagged and sealed, 1/4" VCR
Electrical Options:
2-wire, 4-20mA for hazardous areas
$17,12181
In stock
+
PUR-IS-2W-OEM-(v/wx-yz)
Range:
Non-standard measurement range
Configuration:
Clean room cleaned, single bagged and sealed, 1/4" VCR
Electrical Options:
2-wire, 4-20mA for hazardous areas
$13,87783
In stock
+
PUR-IS-2W-SEN-(-120/-40)
Range:
-184 to -40°F (-120 to -40°C) dp range
Configuration:
Transmitter only, 1/2" VCR
Electrical Options:
2-wire, 4-20mA for hazardous areas
$14,15422
In stock
+
PUR-IS-2W-SEN-(v/wx-yz)
Range:
Non-standard measurement range
Configuration:
Transmitter only, 1/2" VCR
Electrical Options:
2-wire, 4-20mA for hazardous areas
$11,55757
In stock
+
PUR-TX-2W-SEN-(-120/-40)
Range:
-184 to -40°F (-120 to -40°C) dp range
Configuration:
Transmitter only, 1/2" VCR
Electrical Options:
2-wire, 4-20mA
$11,83397
In stock
+
PUR-TX-2W-SEN-(v/wx-yz)
Range:
Non-standard measurement range
Configuration:
Transmitter only, 1/2" VCR
Electrical Options:
2-wire, 4-20mA
$16,26352
In stock
+
PUR-TX-2W-M12-PRM-(-120/-40)
Range:
-184 to -40°F (-120 to -40°C) dp range
Configuration:
Clean room cleaned, inert gas-filled, double bagged and sealed, 1/4” VCR
Electrical Options:
2-wire, 4-20mA with M12 connector
$16,53991
In stock
+
PUR-TX-2W-M12-PRM-(v/wx-yz)
Range:
Non-standard measurement range
Configuration:
Clean room cleaned, inert gas-filled, double bagged and sealed, 1/4” VCR
Electrical Options:
2-wire, 4-20mA with M12 connector
$14,99066
In stock
+
PUR-TX-2W-M12-OEM-(-120/-40)
Range:
-184 to -40°F (-120 to -40°C) dp range
Configuration:
Clean room cleaned, single bagged and sealed, 1/4" VCR
Electrical Options:
2-wire, 4-20mA with M12 connector
$15,26706
In stock
+
PUR-TX-2W-M12-OEM-(v/wx-yz)
Range:
Non-standard measurement range
Configuration:
Clean room cleaned, single bagged and sealed, 1/4" VCR
Electrical Options:
2-wire, 4-20mA with M12 connector
$12,02308
In stock
+
PUR-TX-2W-M12-SEN-(-120/-40)
Range:
-184 to -40°F (-120 to -40°C) dp range
Configuration:
Transmitter only, 1/2" VCR
Electrical Options:
2-wire, 4-20mA with M12 connector
$12,29947
In stock
+
PUR-TX-2W-M12-SEN-(v/wx-yz)
Range:
Non-standard measurement range
Configuration:
Transmitter only, 1/2" VCR
Electrical Options:
2-wire, 4-20mA with M12 connector

Features

  • -184 to -40°Fdp (-120 to -40°Cdp) range
    • Calibrated from -148 to -40°F (-100 to -40°C)
  • Up to ±1.8°F (±1°C) accuracy
  • 10-9 torr to 240 barg operating pressure
  • 2.11 to 10.59 scfh (1 to 5 Nl/min) flow rate
  • 2-wire, 4 to 20mA output
  • 1/4in. & 1/2in. male VCR process connections
  • Optional hazardous area approval

The Michell Instruments Pura pure gas dew point transmitter is a self-contained hygrometer designed specifically to measure trace moisture content in ultra high purity gas applications such as semiconductor manufacturing, fiber optic production, optical ciating processes or pure gas production. The Pura transmitter offers a measurement range of -120 to -40°Cdp (-184°F to -40°Fdp) and is calibrated to -148 to -40°F (-100 to -40°C).

A hazardous area approval is available for the Michell Instruments Pura pure gas dew point transmitter when the 2-wire analog output is selected. The operating pressure for the Pura must fall within 10-9 torr (10-7 Pa) and 240 barg (24 MPa) and the flow rate can be from 2.11 to 10.59 scfh (1 to 5 Nl/min). This Michell Instruments dew point transmitter is available as a standalone sensor or with an optional sampling block.

Michell-Instruments-Pura-Transmitters-Datasheet (Michell-Instruments-Pura-Transmitters-Datasheet.pdf, 1,153 Kb) [Download]

Michell-Pura-Manual (Michell-Pura-Manual.pdf, 936 Kb) [Download]

Michell-Pura-Hazardous-Area-Manual (Michell-Pura-Hazardous-Area-Manual.pdf, 936 Kb) [Download]