Michell Instruments XTP501 Oxygen Analyzer General Purpose Transmitter 0 to 25% Oxygen Power, output & alarm (5m) and loose connector

XTP501-GP2-C3-F2
5,91195
In stock
+
Add to wish list
Delivery
Payment options
Our advantages
  • — 12 months warranty
  • — SMS notification
  • — Return and exchange
  • — Different payment methods
  • — Best price
Column filling
Sort by Price Sort by Availability Sort by CODE Sort by Range Sort by Case & Area Class Sort by Cables
6,42586
In stock
+
XTP501-GP1-C1-F0
Range:
0 to 1% Oxygen
Case & Area Class:
General Purpose Analyzer with display
Cables:
Loose connectors
6,53961
In stock
+
XTP501-GP1-C1-F1
Range:
0 to 1% Oxygen
Case & Area Class:
General Purpose Analyzer with display
Cables:
Power & output (5m) and loose connector
6,60563
In stock
+
XTP501-GP1-C1-F2
Range:
0 to 1% Oxygen
Case & Area Class:
General Purpose Analyzer with display
Cables:
Power, output & alarm (5m) and loose connector
6,67164
In stock
+
XTP501-GP1-C1-F3
Range:
0 to 1% Oxygen
Case & Area Class:
General Purpose Analyzer with display
Cables:
Power, output, alarm & input (5m)
5,97188
In stock
+
XTP501-GP1-C3-F0
Range:
0 to 25% Oxygen
Case & Area Class:
General Purpose Analyzer with display
Cables:
Loose connectors
6,08563
In stock
+
XTP501-GP1-C3-F1
Range:
0 to 25% Oxygen
Case & Area Class:
General Purpose Analyzer with display
Cables:
Power & output (5m) and loose connector
6,15164
In stock
+
XTP501-GP1-C3-F2
Range:
0 to 25% Oxygen
Case & Area Class:
General Purpose Analyzer with display
Cables:
Power, output & alarm (5m) and loose connector
6,21766
In stock
+
XTP501-GP1-C3-F3
Range:
0 to 25% Oxygen
Case & Area Class:
General Purpose Analyzer with display
Cables:
Power, output, alarm & input (5m)
6,42586
In stock
+
XTP501-GP1-C2-F0
Range:
0 to 5% Oxygen
Case & Area Class:
General Purpose Analyzer with display
Cables:
Loose connectors
6,53961
In stock
+
XTP501-GP1-C2-F1
Range:
0 to 5% Oxygen
Case & Area Class:
General Purpose Analyzer with display
Cables:
Power & output (5m) and loose connector
6,60563
In stock
+
XTP501-GP1-C2-F2
Range:
0 to 5% Oxygen
Case & Area Class:
General Purpose Analyzer with display
Cables:
Power, output & alarm (5m) and loose connector
6,67164
In stock
+
XTP501-GP1-C2-F3
Range:
0 to 5% Oxygen
Case & Area Class:
General Purpose Analyzer with display
Cables:
Power, output, alarm & input (5m)
5,97188
In stock
+
XTP501-GP1-C4-F0
Range:
20 to 100% Oxygen
Case & Area Class:
General Purpose Analyzer with display
Cables:
Loose connectors
6,08563
In stock
+
XTP501-GP1-C4-F1
Range:
20 to 100% Oxygen
Case & Area Class:
General Purpose Analyzer with display
Cables:
Power & output (5m) and loose connector
6,15164
In stock
+
XTP501-GP1-C4-F2
Range:
20 to 100% Oxygen
Case & Area Class:
General Purpose Analyzer with display
Cables:
Power, output & alarm (5m) and loose connector
6,21766
In stock
+
XTP501-GP1-C4-F3
Range:
20 to 100% Oxygen
Case & Area Class:
General Purpose Analyzer with display
Cables:
Power, output, alarm & input (5m)
5,97188
In stock
+
XTP501-GP1-C5-F0
Range:
80 to 100% Oxygen
Case & Area Class:
General Purpose Analyzer with display
Cables:
Loose connectors
6,08563
In stock
+
XTP501-GP1-C5-F1
Range:
80 to 100% Oxygen
Case & Area Class:
General Purpose Analyzer with display
Cables:
Power & output (5m) and loose connector
6,15164
In stock
+
XTP501-GP1-C5-F2
Range:
80 to 100% Oxygen
Case & Area Class:
General Purpose Analyzer with display
Cables:
Power, output & alarm (5m) and loose connector
6,21766
In stock
+
XTP501-GP1-C5-F3
Range:
80 to 100% Oxygen
Case & Area Class:
General Purpose Analyzer with display
Cables:
Power, output, alarm & input (5m)
5,97188
In stock
+
XTP501-GP1-C6-F0
Range:
90 to 100% Oxygen
Case & Area Class:
General Purpose Analyzer with display
Cables:
Loose connectors
6,08563
In stock
+
XTP501-GP1-C6-F1
Range:
90 to 100% Oxygen
Case & Area Class:
General Purpose Analyzer with display
Cables:
Power & output (5m) and loose connector
6,15164
In stock
+
XTP501-GP1-C6-F2
Range:
90 to 100% Oxygen
Case & Area Class:
General Purpose Analyzer with display
Cables:
Power, output & alarm (5m) and loose connector
6,21766
In stock
+
XTP501-GP1-C6-F3
Range:
90 to 100% Oxygen
Case & Area Class:
General Purpose Analyzer with display
Cables:
Power, output, alarm & input (5m)
6,18617
In stock
+
XTP501-GP2-C1-F0
Range:
0 to 1% Oxygen
Case & Area Class:
General Purpose Transmitter
Cables:
Loose connectors
6,29992
In stock
+
XTP501-GP2-C1-F1
Range:
0 to 1% Oxygen
Case & Area Class:
General Purpose Transmitter
Cables:
Power & output (5m) and loose connector
6,36594
In stock
+
XTP501-GP2-C1-F2
Range:
0 to 1% Oxygen
Case & Area Class:
General Purpose Transmitter
Cables:
Power, output & alarm (5m) and loose connector
6,43195
In stock
+
XTP501-GP2-C1-F3
Range:
0 to 1% Oxygen
Case & Area Class:
General Purpose Transmitter
Cables:
Power, output, alarm & input (5m)
5,73219
In stock
+
XTP501-GP2-C3-F0
Range:
0 to 25% Oxygen
Case & Area Class:
General Purpose Transmitter
Cables:
Loose connectors
5,84594
In stock
+
XTP501-GP2-C3-F1
Range:
0 to 25% Oxygen
Case & Area Class:
General Purpose Transmitter
Cables:
Power & output (5m) and loose connector
5,91195
In stock
+
XTP501-GP2-C3-F2
Range:
0 to 25% Oxygen
Case & Area Class:
General Purpose Transmitter
Cables:
Power, output & alarm (5m) and loose connector
5,97797
In stock
+
XTP501-GP2-C3-F3
Range:
0 to 25% Oxygen
Case & Area Class:
General Purpose Transmitter
Cables:
Power, output, alarm & input (5m)
6,18617
In stock
+
XTP501-GP2-C2-F0
Range:
0 to 5% Oxygen
Case & Area Class:
General Purpose Transmitter
Cables:
Loose connectors
6,29992
In stock
+
XTP501-GP2-C2-F1
Range:
0 to 5% Oxygen
Case & Area Class:
General Purpose Transmitter
Cables:
Power & output (5m) and loose connector
6,36594
In stock
+
XTP501-GP2-C2-F2
Range:
0 to 5% Oxygen
Case & Area Class:
General Purpose Transmitter
Cables:
Power, output & alarm (5m) and loose connector
6,43195
In stock
+
XTP501-GP2-C2-F3
Range:
0 to 5% Oxygen
Case & Area Class:
General Purpose Transmitter
Cables:
Power, output, alarm & input (5m)
5,73219
In stock
+
XTP501-GP2-C4-F0
Range:
20 to 100% Oxygen
Case & Area Class:
General Purpose Transmitter
Cables:
Loose connectors
5,84594
In stock
+
XTP501-GP2-C4-F1
Range:
20 to 100% Oxygen
Case & Area Class:
General Purpose Transmitter
Cables:
Power & output (5m) and loose connector
5,91195
In stock
+
XTP501-GP2-C4-F2
Range:
20 to 100% Oxygen
Case & Area Class:
General Purpose Transmitter
Cables:
Power, output & alarm (5m) and loose connector
5,97797
In stock
+
XTP501-GP2-C4-F3
Range:
20 to 100% Oxygen
Case & Area Class:
General Purpose Transmitter
Cables:
Power, output, alarm & input (5m)
5,73219
In stock
+
XTP501-GP2-C5-F0
Range:
80 to 100% Oxygen
Case & Area Class:
General Purpose Transmitter
Cables:
Loose connectors
5,84594
In stock
+
XTP501-GP2-C5-F1
Range:
80 to 100% Oxygen
Case & Area Class:
General Purpose Transmitter
Cables:
Power & output (5m) and loose connector
5,91195
In stock
+
XTP501-GP2-C5-F2
Range:
80 to 100% Oxygen
Case & Area Class:
General Purpose Transmitter
Cables:
Power, output & alarm (5m) and loose connector
5,97797
In stock
+
XTP501-GP2-C5-F3
Range:
80 to 100% Oxygen
Case & Area Class:
General Purpose Transmitter
Cables:
Power, output, alarm & input (5m)
5,73219
In stock
+
XTP501-GP2-C6-F0
Range:
90 to 100% Oxygen
Case & Area Class:
General Purpose Transmitter
Cables:
Loose connectors
5,84594
In stock
+
XTP501-GP2-C6-F1
Range:
90 to 100% Oxygen
Case & Area Class:
General Purpose Transmitter
Cables:
Power & output (5m) and loose connector
5,91195
In stock
+
XTP501-GP2-C6-F2
Range:
90 to 100% Oxygen
Case & Area Class:
General Purpose Transmitter
Cables:
Power, output & alarm (5m) and loose connector
5,97797
In stock
+
XTP501-GP2-C6-F3
Range:
90 to 100% Oxygen
Case & Area Class:
General Purpose Transmitter
Cables:
Power, output, alarm & input (5m)

Features

  • Selectable from 0-1% up to 90–100% measurement ranges
  • ±2% accuracy
  • Two 4–20 mA outputs
  • Two alarm relays for concentration
  • 1/8in bulkhead gas fittings
  • MODBUS RTU over RS485 protocol
  • IP55 rated housing

The Michell Instruments XTP501 oxygen analyzer is a linear and stable thermo-paramagnetic analyzer for measurement of oxygen in a variety of applications with background gases such as nitrogen, carbon dioxide, methane and hydrogen. The 316 stainless-steel sensor is housed in a wall-mounted IP55 case suitable for indoor use.

The sensor design largely eliminates drift associated with other comparable devices, improving the stability of the measurement. This allows longer calibration intervals and reduces both labor and consumable costs.

The non-depleting sensor has no moving parts, and is therefore not affected by vibration or movement. This makes it suitable for remote and offshore installations.

Applications for the XTP501 include:

  • Monitoring inert blanketing gases for hydrocarbon processing
  • Inert gas for pharmaceutical or chemical industries
  • Biogas, waste, landfill and digester plants
  • Furnace gas control in steel industry
  • N2 generators
  • O2 generators

XTP_Series_97314_US_Datasheet_v8-1 (XTP_Series_97314_US_Datasheet_v8-1.pdf, 1,180 Kb) [Download]

Michell_XTP501_XTC501_99976_UK_Manual_v1-1 (Michell_XTP501_XTC501_99976_UK_Manual_v1-1.pdf, 3,482 Kb) [Download]

You may be interested
  • Most Popular
  • On Sale
  • Recently Viewed
 
Fast and high quality delivery

Our company makes delivery all over the country

Quality assurance and service

We offer only those goods, in which quality we are sure

Returns within 30 days

You have 30 days to test your purchase