Capteurs différentiels de pH/ORP série AquaMetrix 60/65 ORP Dual output transmitter pH/ORP and temperature Fixed insertion, 1.5in NPT threaded ends, Ryton Hardened glass 15 feet

RT65R8H-015
$39000
En stock
Delivery
Payment options
Our advantages
  • — 12 months warranty
  • — SMS notification
  • — Return and exchange
  • — Different payment methods
  • — Best price
Column filling
Trier par Prix Trier par Disponibilité Trier par Réf. Trier par Longueur du câble Trier par Électrode Trier par Electronics Trier par Application Trier par Type de corps
$91000
En stock
+
RT65R5F-100
Longueur du câble:
100 feet
Électrode:
Flat-faced glass electrode
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$39000
En stock
+
RT65R5F-015
Longueur du câble:
15 feet
Électrode:
Flat-faced glass electrode
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$46800
En stock
+
RT65R5F-050
Longueur du câble:
50 feet
Électrode:
Flat-faced glass electrode
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$91000
En stock
+
RT65R5G-100
Longueur du câble:
100 feet
Électrode:
Gold
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$39000
En stock
+
RT65R5G-015
Longueur du câble:
15 feet
Électrode:
Gold
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$46800
En stock
+
RT65R5G-050
Longueur du câble:
50 feet
Électrode:
Gold
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$91000
En stock
+
RT65R5H-100
Longueur du câble:
100 feet
Électrode:
Hardened glass
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$39000
En stock
+
RT65R5H-015
Longueur du câble:
15 feet
Électrode:
Hardened glass
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$46800
En stock
+
RT65R5H-050
Longueur du câble:
50 feet
Électrode:
Hardened glass
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$78000
En stock
+
RT65R5-100
Longueur du câble:
100 feet
Électrode:
Standard electrode
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$26000
En stock
+
RT65R5-015
Longueur du câble:
15 feet
Électrode:
Standard electrode
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$33800
En stock
+
RT65R5-050
Longueur du câble:
50 feet
Électrode:
Standard electrode
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$91000
En stock
+
RT65R8F-100
Longueur du câble:
100 feet
Électrode:
Flat-faced glass electrode
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$39000
En stock
+
RT65R8F-015
Longueur du câble:
15 feet
Électrode:
Flat-faced glass electrode
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$46800
En stock
+
RT65R8F-050
Longueur du câble:
50 feet
Électrode:
Flat-faced glass electrode
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$91000
En stock
+
RT65R8G-100
Longueur du câble:
100 feet
Électrode:
Gold
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$39000
En stock
+
RT65R8G-015
Longueur du câble:
15 feet
Électrode:
Gold
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$46800
En stock
+
RT65R8G-050
Longueur du câble:
50 feet
Électrode:
Gold
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$91000
En stock
+
RT65R8H-100
Longueur du câble:
100 feet
Électrode:
Hardened glass
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$39000
En stock
+
RT65R8H-015
Longueur du câble:
15 feet
Électrode:
Hardened glass
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$46800
En stock
+
RT65R8H-050
Longueur du câble:
50 feet
Électrode:
Hardened glass
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$78000
En stock
+
RT65R8-100
Longueur du câble:
100 feet
Électrode:
Standard electrode
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$26000
En stock
+
RT65R8-015
Longueur du câble:
15 feet
Électrode:
Standard electrode
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$33800
En stock
+
RT65R8-050
Longueur du câble:
50 feet
Électrode:
Standard electrode
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$65000
En stock
+
R60R5F-100
Longueur du câble:
100 feet
Électrode:
Flat-faced glass electrode
Electronics:
Standard 5-wire sensor
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$13000
En stock
+
R60R5F-015
Longueur du câble:
15 feet
Électrode:
Flat-faced glass electrode
Electronics:
Standard 5-wire sensor
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$20800
En stock
+
R60R5F-050
Longueur du câble:
50 feet
Électrode:
Flat-faced glass electrode
Electronics:
Standard 5-wire sensor
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$65000
En stock
+
R60R5G-100
Longueur du câble:
100 feet
Électrode:
Gold
Electronics:
Standard 5-wire sensor
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$13000
En stock
+
R60R5G-015
Longueur du câble:
15 feet
Électrode:
Gold
Electronics:
Standard 5-wire sensor
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$20800
En stock
+
R60R5G-050
Longueur du câble:
50 feet
Électrode:
Gold
Electronics:
Standard 5-wire sensor
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$65000
En stock
+
R60R5H-100
Longueur du câble:
100 feet
Électrode:
Hardened glass
Electronics:
Standard 5-wire sensor
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$13000
En stock
+
R60R5H-015
Longueur du câble:
15 feet
Électrode:
Hardened glass
Electronics:
Standard 5-wire sensor
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$20800
En stock
+
R60R5H-050
Longueur du câble:
50 feet
Électrode:
Hardened glass
Electronics:
Standard 5-wire sensor
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$52000
En stock
+
R60R5-100
Longueur du câble:
100 feet
Électrode:
Standard electrode
Electronics:
Standard 5-wire sensor
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
[Nous contacter pour un prix]
En stock
R60R5-015
Longueur du câble:
15 feet
Électrode:
Standard electrode
Electronics:
Standard 5-wire sensor
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$7800
En stock
+
R60R5-050
Longueur du câble:
50 feet
Électrode:
Standard electrode
Electronics:
Standard 5-wire sensor
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$65000
En stock
+
R60R8F-100
Longueur du câble:
100 feet
Électrode:
Flat-faced glass electrode
Electronics:
Standard 5-wire sensor
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$13000
En stock
+
R60R8F-015
Longueur du câble:
15 feet
Électrode:
Flat-faced glass electrode
Electronics:
Standard 5-wire sensor
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$20800
En stock
+
R60R8F-050
Longueur du câble:
50 feet
Électrode:
Flat-faced glass electrode
Electronics:
Standard 5-wire sensor
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$65000
En stock
+
R60R8G-100
Longueur du câble:
100 feet
Électrode:
Gold
Electronics:
Standard 5-wire sensor
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$13000
En stock
+
R60R8G-015
Longueur du câble:
15 feet
Électrode:
Gold
Electronics:
Standard 5-wire sensor
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$20800
En stock
+
R60R8G-050
Longueur du câble:
50 feet
Électrode:
Gold
Electronics:
Standard 5-wire sensor
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$65000
En stock
+
R60R8H-100
Longueur du câble:
100 feet
Électrode:
Hardened glass
Electronics:
Standard 5-wire sensor
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$13000
En stock
+
R60R8H-015
Longueur du câble:
15 feet
Électrode:
Hardened glass
Electronics:
Standard 5-wire sensor
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$20800
En stock
+
R60R8H-050
Longueur du câble:
50 feet
Électrode:
Hardened glass
Electronics:
Standard 5-wire sensor
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$52000
En stock
+
R60R8-100
Longueur du câble:
100 feet
Électrode:
Standard electrode
Electronics:
Standard 5-wire sensor
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
[Nous contacter pour un prix]
En stock
R60R8-015
Longueur du câble:
15 feet
Électrode:
Standard electrode
Electronics:
Standard 5-wire sensor
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$7800
En stock
+
R60R8-050
Longueur du câble:
50 feet
Électrode:
Standard electrode
Electronics:
Standard 5-wire sensor
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$78000
En stock
+
R65R5F-100
Longueur du câble:
100 feet
Électrode:
Flat-faced glass electrode
Electronics:
Two wire transmitter, 4-20mA output
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$26000
En stock
+
R65R5F-015
Longueur du câble:
15 feet
Électrode:
Flat-faced glass electrode
Electronics:
Two wire transmitter, 4-20mA output
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$33800
En stock
+
R65R5F-050
Longueur du câble:
50 feet
Électrode:
Flat-faced glass electrode
Electronics:
Two wire transmitter, 4-20mA output
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$78000
En stock
+
R65R5G-100
Longueur du câble:
100 feet
Électrode:
Gold
Electronics:
Two wire transmitter, 4-20mA output
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$26000
En stock
+
R65R5G-015
Longueur du câble:
15 feet
Électrode:
Gold
Electronics:
Two wire transmitter, 4-20mA output
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$33800
En stock
+
R65R5G-050
Longueur du câble:
50 feet
Électrode:
Gold
Electronics:
Two wire transmitter, 4-20mA output
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$78000
En stock
+
R65R5H-100
Longueur du câble:
100 feet
Électrode:
Hardened glass
Electronics:
Two wire transmitter, 4-20mA output
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$26000
En stock
+
R65R5H-015
Longueur du câble:
15 feet
Électrode:
Hardened glass
Electronics:
Two wire transmitter, 4-20mA output
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$33800
En stock
+
R65R5H-050
Longueur du câble:
50 feet
Électrode:
Hardened glass
Electronics:
Two wire transmitter, 4-20mA output
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$65000
En stock
+
R65R5-100
Longueur du câble:
100 feet
Électrode:
Standard electrode
Electronics:
Two wire transmitter, 4-20mA output
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$13000
En stock
+
R65R5-015
Longueur du câble:
15 feet
Électrode:
Standard electrode
Electronics:
Two wire transmitter, 4-20mA output
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$20800
En stock
+
R65R5-050
Longueur du câble:
50 feet
Électrode:
Standard electrode
Electronics:
Two wire transmitter, 4-20mA output
Application:
ORP
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$78000
En stock
+
R65R8F-100
Longueur du câble:
100 feet
Électrode:
Flat-faced glass electrode
Electronics:
Two wire transmitter, 4-20mA output
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$26000
En stock
+
R65R8F-015
Longueur du câble:
15 feet
Électrode:
Flat-faced glass electrode
Electronics:
Two wire transmitter, 4-20mA output
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$33800
En stock
+
R65R8F-050
Longueur du câble:
50 feet
Électrode:
Flat-faced glass electrode
Electronics:
Two wire transmitter, 4-20mA output
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$78000
En stock
+
R65R8G-100
Longueur du câble:
100 feet
Électrode:
Gold
Electronics:
Two wire transmitter, 4-20mA output
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$26000
En stock
+
R65R8G-015
Longueur du câble:
15 feet
Électrode:
Gold
Electronics:
Two wire transmitter, 4-20mA output
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$33800
En stock
+
R65R8G-050
Longueur du câble:
50 feet
Électrode:
Gold
Electronics:
Two wire transmitter, 4-20mA output
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$78000
En stock
+
R65R8H-100
Longueur du câble:
100 feet
Électrode:
Hardened glass
Electronics:
Two wire transmitter, 4-20mA output
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$26000
En stock
+
R65R8H-015
Longueur du câble:
15 feet
Électrode:
Hardened glass
Electronics:
Two wire transmitter, 4-20mA output
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$33800
En stock
+
R65R8H-050
Longueur du câble:
50 feet
Électrode:
Hardened glass
Electronics:
Two wire transmitter, 4-20mA output
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$65000
En stock
+
R65R8-100
Longueur du câble:
100 feet
Électrode:
Standard electrode
Electronics:
Two wire transmitter, 4-20mA output
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$13000
En stock
+
R65R8-015
Longueur du câble:
15 feet
Électrode:
Standard electrode
Electronics:
Two wire transmitter, 4-20mA output
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$20800
En stock
+
R65R8-050
Longueur du câble:
50 feet
Électrode:
Standard electrode
Electronics:
Two wire transmitter, 4-20mA output
Application:
ORP
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$91000
En stock
+
PT65R5F-100
Longueur du câble:
100 feet
Électrode:
Flat-faced glass electrode
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$39000
En stock
+
PT65R5F-015
Longueur du câble:
15 feet
Électrode:
Flat-faced glass electrode
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$46800
En stock
+
PT65R5F-050
Longueur du câble:
50 feet
Électrode:
Flat-faced glass electrode
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$91000
En stock
+
PT65R5G-100
Longueur du câble:
100 feet
Électrode:
Gold
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$39000
En stock
+
PT65R5G-015
Longueur du câble:
15 feet
Électrode:
Gold
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$46800
En stock
+
PT65R5G-050
Longueur du câble:
50 feet
Électrode:
Gold
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$91000
En stock
+
PT65R5H-100
Longueur du câble:
100 feet
Électrode:
Hardened glass
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$39000
En stock
+
PT65R5H-015
Longueur du câble:
15 feet
Électrode:
Hardened glass
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$46800
En stock
+
PT65R5H-050
Longueur du câble:
50 feet
Électrode:
Hardened glass
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$78000
En stock
+
PT65R5-100
Longueur du câble:
100 feet
Électrode:
Standard electrode
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$26000
En stock
+
PT65R5-015
Longueur du câble:
15 feet
Électrode:
Standard electrode
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$33800
En stock
+
PT65R5-050
Longueur du câble:
50 feet
Électrode:
Standard electrode
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton
$1,04000
En stock
+
PT65R8AA-100
Longueur du câble:
100 feet
Électrode:
Antimony (for HF acid, not covered by warranty)
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$52000
En stock
+
PT65R8AA-015
Longueur du câble:
15 feet
Électrode:
Antimony (for HF acid, not covered by warranty)
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$59800
En stock
+
PT65R8AA-050
Longueur du câble:
50 feet
Électrode:
Antimony (for HF acid, not covered by warranty)
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$91000
En stock
+
PT65R8F-100
Longueur du câble:
100 feet
Électrode:
Flat-faced glass electrode
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$39000
En stock
+
PT65R8F-015
Longueur du câble:
15 feet
Électrode:
Flat-faced glass electrode
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$46800
En stock
+
PT65R8F-050
Longueur du câble:
50 feet
Électrode:
Flat-faced glass electrode
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$91000
En stock
+
PT65R8G-100
Longueur du câble:
100 feet
Électrode:
Gold
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$39000
En stock
+
PT65R8G-015
Longueur du câble:
15 feet
Électrode:
Gold
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$46800
En stock
+
PT65R8G-050
Longueur du câble:
50 feet
Électrode:
Gold
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$91000
En stock
+
PT65R8H-100
Longueur du câble:
100 feet
Électrode:
Hardened glass
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$39000
En stock
+
PT65R8H-015
Longueur du câble:
15 feet
Électrode:
Hardened glass
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$46800
En stock
+
PT65R8H-050
Longueur du câble:
50 feet
Électrode:
Hardened glass
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$78000
En stock
+
PT65R8-100
Longueur du câble:
100 feet
Électrode:
Standard electrode
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$26000
En stock
+
PT65R8-015
Longueur du câble:
15 feet
Électrode:
Standard electrode
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$33800
En stock
+
PT65R8-050
Longueur du câble:
50 feet
Électrode:
Standard electrode
Electronics:
Dual output transmitter pH/ORP and temperature
Application:
pH
Type de corps:
Fixed insertion, 1.5in NPT threaded ends, Ryton
$65000
En stock
+
P60R5F-100
Longueur du câble:
100 feet
Électrode:
Flat-faced glass electrode
Electronics:
Standard 5-wire sensor
Application:
pH
Type de corps:
Fixed insertion, 1.0in NPT threaded ends, Ryton

Caractéristiques

  • Plage de mesure
    • 0 à 14 pH
    • ±500 mV à ±2000 mV
  • Sensibilité
    • 0,001 pH à 0,01 pH
    • 0,1 mV ORP
  • Stabilité (non cumulative)
    • 0,03 pH par jour
    • 2 mV par jour ORP
  • Débit de 10 pi/sec (3 m/sec)
  • Limite de température de 23 à 203 °F (-5 à 95 °C)
  • 100 PSIG à Limite de pression de 65 °C
  • Pont salin remplaçable
  • Tableau de conversion GLI (Great Lakes Instruments)

Les capteurs différentiels de pH / ORP de la série AquaMetrix 60/65 sont des capteurs de qualité industrielle fiables conçus pour fournir des mesures précises et une durée de vie plus longue dans les conditions les plus exigeantes. Certaines caractéristiques de ces sondes comprennent : la technologie de mesure différentielle, le pont salin remplaçable et le préamplificateur encapsulé.

Les capteurs différentiels de pH / ORP de la série AquaMetrix 60/65 intègrent tous les avantages de la mesure différentielle éprouvée sur le terrain dans des milliers d'installations. Cette technique utilise deux électrodes en verre pour effectuer la mesure de manière différentielle par rapport à une troisième électrode métallique. L'électrode de traitement en verre bombée est spécialement conçue pour les applications difficiles. La deuxième électrode est immergée dans un tampon pH 7 encapsulé dans la sonde.

Cette deuxième électrode est protégée du processus par un pont salin remplaçable à double jonction. La mesure différentielle réelle qui en résulte présente plusieurs avantages par rapport aux sondes conventionnelles : les problèmes de boucle de masse sont pratiquement éliminés et le pont salin est facilement remplaçable.

Si la solution interne est contaminée, la sonde peut être rajeunie à un coût modeste en remplaçant le pont salin et la solution de référence. La compensation automatique de la température est réalisée grâce à l'utilisation d'une thermistance à l'extrémité de la sonde. Ce placement de la thermistance fournit une réponse rapide aux variations de température du processus.

Le préamplificateur encapsulé fournit un signal de sortie qui peut être transmis sur 3000 pieds sur un câble peu coûteux. Une autre version encapsule un émetteur à deux fils 4-20 mA aveugle qui peut transmettre sur une distance pratiquement illimitée sur un câble à paire torsadée. (Voir la fiche technique P/R65).

Applications des capteurs différentiels de pH/ORP AquaMetrix série 60/65

  • Contrôle des procédés
  • Traitement des eaux industrielles et municipales
  • Traitement et neutralisation des déchets industriels et municipaux
  • Épurateurs de fumées
  • Placage
  • Fabrication de circuits imprimés
  • Alimentation et boissons
  • Traitement chimique
  • Pâte à papier et papier
  • Exploitation minière
  • Production d'énergie
  • Industrie pharmaceutique

PR60R8-datasheet (PR60R8-datasheet.pdf, 545 Kb) [Télécharger]

AquaMetrix-PR60R5-Datasheet (AquaMetrix-PR60R5-Datasheet.pdf, 532 Kb) [Télécharger]

PR60C-6or7-variable-datasheet (PR60C-6or7-variable-datasheet.pdf, 531 Kb) [Télécharger]

PR65C-datasheet (PR65C-datasheet.pdf, 541 Kb) [Télécharger]

PR60-PR65-manual (PR60-PR65-manual.pdf, 1,110 Kb) [Télécharger]

Aquametrix-Hach-GLI-CompatibilityGuide (Aquametrix-Hach-GLI-CompatibilityGuide.pdf, 531 Kb) [Télécharger]

You may be interested
  • Most Popular
  • On Sale
  • Recently Viewed
 
Fast and high quality delivery

Our company makes delivery all over the country

Quality assurance and service

We offer only those goods, in which quality we are sure

Returns within 30 days

You have 30 days to test your purchase