Rosemount Analytical Model 3900 pH/ORP Sensor Sensor with integral cable SMART Preamplifier 66' (20m) cable (Standard Preamp if used with ORP) Platinum ORP Certificate of Calibration (no test data given)

3900-05-12-CC
99328
In stock
+
Add to wish list
Delivery
Payment options
Our advantages
  • — 12 months warranty
  • — SMS notification
  • — Return and exchange
  • — Different payment methods
  • — Best price
Column filling
Sort by Price Sort by Availability Sort by CODE Sort by Measurement Type Sort by Calibration and Conformance Certificates Sort by Preamplifier Sort by Stylus
53422
In stock
+
3900-08-10-CC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
No Preamplifier 10' cable
Stylus:
Sensor with integral cable
71703
In stock
+
3900-08-10-EC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
No Preamplifier 10' cable
Stylus:
Sensor with integral cable
94859
In stock
+
3900-08-10-LC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Loop Calibration (sensor & transmitter calibrated together w/ test data)
Preamplifier:
No Preamplifier 10' cable
Stylus:
Sensor with integral cable
48445
In stock
+
3900-08-10
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Without
Preamplifier:
No Preamplifier 10' cable
Stylus:
Sensor with integral cable
62055
In stock
+
3900-08-12-CC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
No Preamplifier 10' cable
Stylus:
Sensor with integral cable
80336
In stock
+
3900-08-12-EC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
No Preamplifier 10' cable
Stylus:
Sensor with integral cable
1,03492
In stock
+
3900-08-12-LC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Loop Calibration (sensor & transmitter calibrated together w/ test data)
Preamplifier:
No Preamplifier 10' cable
Stylus:
Sensor with integral cable
57078
In stock
+
3900-08-12
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Without
Preamplifier:
No Preamplifier 10' cable
Stylus:
Sensor with integral cable
50273
In stock
+
3900-07-10-CC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
No Preamplifier 4' cable
Stylus:
Sensor with integral cable
68555
In stock
+
3900-07-10-EC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
No Preamplifier 4' cable
Stylus:
Sensor with integral cable
91711
In stock
+
3900-07-10-LC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Loop Calibration (sensor & transmitter calibrated together w/ test data)
Preamplifier:
No Preamplifier 4' cable
Stylus:
Sensor with integral cable
45297
In stock
+
3900-07-10
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Without
Preamplifier:
No Preamplifier 4' cable
Stylus:
Sensor with integral cable
58906
In stock
+
3900-07-12-CC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
No Preamplifier 4' cable
Stylus:
Sensor with integral cable
77188
In stock
+
3900-07-12-EC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
No Preamplifier 4' cable
Stylus:
Sensor with integral cable
1,00344
In stock
+
3900-07-12-LC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Loop Calibration (sensor & transmitter calibrated together w/ test data)
Preamplifier:
No Preamplifier 4' cable
Stylus:
Sensor with integral cable
53930
In stock
+
3900-07-12
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Without
Preamplifier:
No Preamplifier 4' cable
Stylus:
Sensor with integral cable
55961
In stock
+
3900-02-10-CC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
No Preamplifier, 15' (5m) cable
Stylus:
Sensor with integral cable
74242
In stock
+
3900-02-10-EC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
No Preamplifier, 15' (5m) cable
Stylus:
Sensor with integral cable
50984
In stock
+
3900-02-10
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Without
Preamplifier:
No Preamplifier, 15' (5m) cable
Stylus:
Sensor with integral cable
64594
In stock
+
3900-02-12-CC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
No Preamplifier, 15' (5m) cable
Stylus:
Sensor with integral cable
82875
In stock
+
3900-02-12-EC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
No Preamplifier, 15' (5m) cable
Stylus:
Sensor with integral cable
1,06031
In stock
+
3900-02-12-LC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Loop Calibration (sensor & transmitter calibrated together w/ test data)
Preamplifier:
No Preamplifier, 15' (5m) cable
Stylus:
Sensor with integral cable
59617
In stock
+
3900-02-12
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Without
Preamplifier:
No Preamplifier, 15' (5m) cable
Stylus:
Sensor with integral cable
66219
In stock
+
3900-01-10-CC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
SMART Preamplifier (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
84500
In stock
+
3900-01-10-EC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
SMART Preamplifier (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
61242
In stock
+
3900-01-10
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Without
Preamplifier:
SMART Preamplifier (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
74852
In stock
+
3900-01-12-CC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
SMART Preamplifier (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
93133
In stock
+
3900-01-12-EC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
SMART Preamplifier (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
1,16289
In stock
+
3900-01-12-LC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Loop Calibration (sensor & transmitter calibrated together w/ test data)
Preamplifier:
SMART Preamplifier (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
69875
In stock
+
3900-01-12
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Without
Preamplifier:
SMART Preamplifier (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
1,08469
In stock
+
3900-06-10-CC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
SMART Preamplifier 100' cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
1,26750
In stock
+
3900-06-10-EC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
SMART Preamplifier 100' cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
1,03492
In stock
+
3900-06-10
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Without
Preamplifier:
SMART Preamplifier 100' cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
1,17102
In stock
+
3900-06-12-CC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
SMART Preamplifier 100' cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
1,35383
In stock
+
3900-06-12-EC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
SMART Preamplifier 100' cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
1,58539
In stock
+
3900-06-12-LC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Loop Calibration (sensor & transmitter calibrated together w/ test data)
Preamplifier:
SMART Preamplifier 100' cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
1,12125
In stock
+
3900-06-12
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Without
Preamplifier:
SMART Preamplifier 100' cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
82367
In stock
+
3900-04-10-CC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
SMART Preamplifier 50' cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
1,00648
In stock
+
3900-04-10-EC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
SMART Preamplifier 50' cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
77391
In stock
+
3900-04-10
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Without
Preamplifier:
SMART Preamplifier 50' cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
91000
In stock
+
3900-04-12-CC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
SMART Preamplifier 50' cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
1,09281
In stock
+
3900-04-12-EC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
SMART Preamplifier 50' cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
1,32438
In stock
+
3900-04-12-LC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Loop Calibration (sensor & transmitter calibrated together w/ test data)
Preamplifier:
SMART Preamplifier 50' cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
86023
In stock
+
3900-04-12
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Without
Preamplifier:
SMART Preamplifier 50' cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
90695
In stock
+
3900-05-10-CC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
SMART Preamplifier 66' (20m) cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
1,08977
In stock
+
3900-05-10-EC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
SMART Preamplifier 66' (20m) cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
85719
In stock
+
3900-05-10
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Without
Preamplifier:
SMART Preamplifier 66' (20m) cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
99328
In stock
+
3900-05-12-CC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
SMART Preamplifier 66' (20m) cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
1,17609
In stock
+
3900-05-12-EC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
SMART Preamplifier 66' (20m) cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
1,40766
In stock
+
3900-05-12-LC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Loop Calibration (sensor & transmitter calibrated together w/ test data)
Preamplifier:
SMART Preamplifier 66' (20m) cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
94352
In stock
+
3900-05-12
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Without
Preamplifier:
SMART Preamplifier 66' (20m) cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
72922
In stock
+
3900-01-10-CC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
SMART Preamplifier, 32' (10m) cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
91203
In stock
+
3900-01-10-EC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
SMART Preamplifier, 32' (10m) cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
67945
In stock
+
3900-01-10
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Without
Preamplifier:
SMART Preamplifier, 32' (10m) cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
81555
In stock
+
3900-01-12-CC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
SMART Preamplifier, 32' (10m) cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
99836
In stock
+
3900-01-12-EC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
SMART Preamplifier, 32' (10m) cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
1,22992
In stock
+
3900-01-12-LC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Loop Calibration (sensor & transmitter calibrated together w/ test data)
Preamplifier:
SMART Preamplifier, 32' (10m) cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
76578
In stock
+
3900-01-12
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Without
Preamplifier:
SMART Preamplifier, 32' (10m) cable (Standard Preamp if used with ORP)
Stylus:
Sensor with integral cable
50273
In stock
+
3900-02-10-CC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
Without preamplifier
Stylus:
Sensor with integral cable
68555
In stock
+
3900-02-10-EC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
Without preamplifier
Stylus:
Sensor with integral cable
45297
In stock
+
3900-02-10
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Without
Preamplifier:
Without preamplifier
Stylus:
Sensor with integral cable
58906
In stock
+
3900-02-12-CC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
Without preamplifier
Stylus:
Sensor with integral cable
77188
In stock
+
3900-02-12-EC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
Without preamplifier
Stylus:
Sensor with integral cable
1,00344
In stock
+
3900-02-12-LC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Loop Calibration (sensor & transmitter calibrated together w/ test data)
Preamplifier:
Without preamplifier
Stylus:
Sensor with integral cable
53930
In stock
+
3900-02-12
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Without
Preamplifier:
Without preamplifier
Stylus:
Sensor with integral cable
56672
In stock
+
3900VP-08-10-CC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
No Preamplifier 10' cable
Stylus:
Sensor with VP8 connector
74953
In stock
+
3900VP-08-10-EC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
No Preamplifier 10' cable
Stylus:
Sensor with VP8 connector
98109
In stock
+
3900VP-08-10-LC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Loop Calibration (sensor & transmitter calibrated together w/ test data)
Preamplifier:
No Preamplifier 10' cable
Stylus:
Sensor with VP8 connector
51695
In stock
+
3900VP-08-10
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Without
Preamplifier:
No Preamplifier 10' cable
Stylus:
Sensor with VP8 connector
65305
In stock
+
3900VP-08-12-CC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
No Preamplifier 10' cable
Stylus:
Sensor with VP8 connector
83586
In stock
+
3900VP-08-12-EC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
No Preamplifier 10' cable
Stylus:
Sensor with VP8 connector
1,06742
In stock
+
3900VP-08-12-LC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Loop Calibration (sensor & transmitter calibrated together w/ test data)
Preamplifier:
No Preamplifier 10' cable
Stylus:
Sensor with VP8 connector
60328
In stock
+
3900VP-08-12
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Without
Preamplifier:
No Preamplifier 10' cable
Stylus:
Sensor with VP8 connector
53523
In stock
+
3900VP-07-10-CC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
No Preamplifier 4' cable
Stylus:
Sensor with VP8 connector
71805
In stock
+
3900VP-07-10-EC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
No Preamplifier 4' cable
Stylus:
Sensor with VP8 connector
94961
In stock
+
3900VP-07-10-LC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Loop Calibration (sensor & transmitter calibrated together w/ test data)
Preamplifier:
No Preamplifier 4' cable
Stylus:
Sensor with VP8 connector
48547
In stock
+
3900VP-07-10
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Without
Preamplifier:
No Preamplifier 4' cable
Stylus:
Sensor with VP8 connector
62156
In stock
+
3900VP-07-12-CC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
No Preamplifier 4' cable
Stylus:
Sensor with VP8 connector
80438
In stock
+
3900VP-07-12-EC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
No Preamplifier 4' cable
Stylus:
Sensor with VP8 connector
1,03594
In stock
+
3900VP-07-12-LC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Loop Calibration (sensor & transmitter calibrated together w/ test data)
Preamplifier:
No Preamplifier 4' cable
Stylus:
Sensor with VP8 connector
57180
In stock
+
3900VP-07-12
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Without
Preamplifier:
No Preamplifier 4' cable
Stylus:
Sensor with VP8 connector
59211
In stock
+
3900VP-02-10-CC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
No Preamplifier, 15' (5m) cable
Stylus:
Sensor with VP8 connector
77492
In stock
+
3900VP-02-10-EC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
No Preamplifier, 15' (5m) cable
Stylus:
Sensor with VP8 connector
54234
In stock
+
3900VP-02-10
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Without
Preamplifier:
No Preamplifier, 15' (5m) cable
Stylus:
Sensor with VP8 connector
67844
In stock
+
3900VP-02-12-CC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
No Preamplifier, 15' (5m) cable
Stylus:
Sensor with VP8 connector
86125
In stock
+
3900VP-02-12-EC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
No Preamplifier, 15' (5m) cable
Stylus:
Sensor with VP8 connector
1,09281
In stock
+
3900VP-02-12-LC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Loop Calibration (sensor & transmitter calibrated together w/ test data)
Preamplifier:
No Preamplifier, 15' (5m) cable
Stylus:
Sensor with VP8 connector
62867
In stock
+
3900VP-02-12
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Without
Preamplifier:
No Preamplifier, 15' (5m) cable
Stylus:
Sensor with VP8 connector
69469
In stock
+
3900VP-01-10-CC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
SMART Preamplifier (Standard Preamp if used with ORP)
Stylus:
Sensor with VP8 connector
87750
In stock
+
3900VP-01-10-EC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
SMART Preamplifier (Standard Preamp if used with ORP)
Stylus:
Sensor with VP8 connector
64492
In stock
+
3900VP-01-10
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Without
Preamplifier:
SMART Preamplifier (Standard Preamp if used with ORP)
Stylus:
Sensor with VP8 connector
78102
In stock
+
3900VP-01-12-CC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
SMART Preamplifier (Standard Preamp if used with ORP)
Stylus:
Sensor with VP8 connector
96383
In stock
+
3900VP-01-12-EC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
SMART Preamplifier (Standard Preamp if used with ORP)
Stylus:
Sensor with VP8 connector
1,19539
In stock
+
3900VP-01-12-LC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Loop Calibration (sensor & transmitter calibrated together w/ test data)
Preamplifier:
SMART Preamplifier (Standard Preamp if used with ORP)
Stylus:
Sensor with VP8 connector
73125
In stock
+
3900VP-01-12
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Without
Preamplifier:
SMART Preamplifier (Standard Preamp if used with ORP)
Stylus:
Sensor with VP8 connector
1,11719
In stock
+
3900VP-06-10-CC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
SMART Preamplifier 100' cable (Standard Preamp if used with ORP)
Stylus:
Sensor with VP8 connector
1,30000
In stock
+
3900VP-06-10-EC
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
SMART Preamplifier 100' cable (Standard Preamp if used with ORP)
Stylus:
Sensor with VP8 connector
1,06742
In stock
+
3900VP-06-10
Measurement Type:
General Purpose Low Resistivity pH Glass (0-14pH)
Calibration and Conformance Certificates:
Without
Preamplifier:
SMART Preamplifier 100' cable (Standard Preamp if used with ORP)
Stylus:
Sensor with VP8 connector
1,20352
In stock
+
3900VP-06-12-CC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Certificate of Calibration (no test data given)
Preamplifier:
SMART Preamplifier 100' cable (Standard Preamp if used with ORP)
Stylus:
Sensor with VP8 connector
1,38633
In stock
+
3900VP-06-12-EC
Measurement Type:
Platinum ORP
Calibration and Conformance Certificates:
Electronic Calibration (with test data)
Preamplifier:
SMART Preamplifier 100' cable (Standard Preamp if used with ORP)
Stylus:
Sensor with VP8 connector

Features

  • SMART enabled
  • Available in hemi bulb, flat bulb, HF resistant, and Hi pH glass
  • Special features for processes with low conductivity, hydrofluoric acid, high pH, and reference poisoning elements
  • Watertight VP8 multiple-pin connector available which eliminates cable twisting.
  • Double or triple junction reference cell
  • Various mounting options
  • Sealed PPS body provides maximum protection

The Rosemount Analytical 3900 and 3900VP General purpose pH/ORP sensor models are provided with a double junction reference, which protects the reference element from poisoning ions – such as ammonia, chlorine, cyanides, and sulfides – in the process. The double junction reference aids in the sensor's resistance to harsh environments and helps prolong sensor life. Both models are made with porous Teflon® junction positioned near the pH/ORP-sensitive membrane.

The AccuGLASS pH glass formulations exceed industry standards. The AccuGlass pH glass is a result of many years of glass research resulting in a formulation which has been found to increase the life of the sensor. Unlike other pH glasses presently on the market, this glass resists cracking especially at higher temperatures and reduces sodium ion error commonly found in high pH applications. Overall, the AccuGlass formulation enhances the sensor performance to measure pH more accurately and have a longer sensor life than ever before.

Model 3900VP is offered with a watertight sensor-to-cable connector which eliminates re-wiring and cable twisting when replacing sensors. The Variopol VP multiple pin connector is an integral part of each sensor model and uses a mating VP cable. Once the cable is installed and wired to the analyzer, sensors are easily replaced without replacing the cable and without rewiring the analyzer. Also the cable can be disconnected from the sensor before removal from the process which eliminates cable twisting.

Models 3900 and 3900VP are housed in a molded PPS body, making each sensor virtually indestructible and chemically resistant. Complete encapsulation eliminates leakage or high humidity problems traditionally found in other pH/ORP designs. The simplified construction, designed with user convenience in mind does not require electrolyte (KCl) replenishment or any high maintenance troubleshooting procedures.

Installation is easily achieved through the wide variety of mounting configurations. Both Models feature 1'' and 3⁄4'' inch (MNPT) front facing connections for insertion, submersion, or flow-through pH and ORP applications.

Both models are combination sensors (pH, reference, and temperature within sensor body) and measure pH or ORP (Oxidation/Reduction Potential) of aqueous solutions in pipelines, open tanks, or ponds. Models 3900 and 3900VP are suitable for virtually all applications and are compatible with Rosemount Analytical and other manufacturers' instruments.

roduct-data-sheet-3900-3900vp-general-purpose-ph-orp-sensors-rosemount-en-70722 (product-data-sheet-3900-3900vp-general-purpose-ph-orp-sensors-rosemount-en-70722.pdf, 651 Kb) [Download]

rosemount-3900_manual (rosemount-3900_manual.pdf, 818 Kb) [Download]

RosemountAnalyticalLiquidAnalysisAccessoryGuide (RosemountAnalyticalLiquidAnalysisAccessoryGuide.pdf, 7,189 Kb) [Download]

You may be interested
  • Most Popular
  • On Sale
  • Recently Viewed
 
Fast and high quality delivery

Our company makes delivery all over the country

Quality assurance and service

We offer only those goods, in which quality we are sure

Returns within 30 days

You have 30 days to test your purchase