Ametek PK II Pneumatic Deadweight Tester g/cm² 4 to 854 inH2O (1 inH2O increments) ±0.050% of reading; standard or local gravity; no calibration report

PK2-854WC-SS
£10,03351
In stock
+
Add to wish list
Delivery
Payment options
Our advantages
  • — 12 months warranty
  • — SMS notification
  • — Return and exchange
  • — Different payment methods
  • — Best price
Column filling
Sort by Price Sort by Availability Sort by CODE Sort by Calibration Sort by Pressure Range Sort by Pressure Unit
£12,39495
In stock
+
PK2-2B.01-SS-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 2 bar (0.005 bar increments)
Pressure Unit:
bar
£13,01106
In stock
+
PK2-2B.01-SS-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 2 bar (0.005 bar increments)
Pressure Unit:
bar
£11,48979
In stock
+
PK2-2B.01-SS-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 2 bar (0.005 bar increments)
Pressure Unit:
bar
£12,10176
In stock
+
PK2-2B.01-SS-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 2 bar (0.005 bar increments)
Pressure Unit:
bar
£10,62197
In stock
+
PK2-2B.01-SS
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
0.01 to 2 bar (0.005 bar increments)
Pressure Unit:
bar
£11,23809
In stock
+
PK2-2B.01-SS/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
0.01 to 2 bar (0.005 bar increments)
Pressure Unit:
bar
£11,30309
In stock
+
PK2-2B-SS-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
0.02 to 2 bar (0.02 bar increments)
Pressure Unit:
bar
£11,91920
In stock
+
PK2-2B-SS-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
0.02 to 2 bar (0.02 bar increments)
Pressure Unit:
bar
£10,39793
In stock
+
PK2-2B-SS-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
0.02 to 2 bar (0.02 bar increments)
Pressure Unit:
bar
£11,00989
In stock
+
PK2-2B-SS-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
0.02 to 2 bar (0.02 bar increments)
Pressure Unit:
bar
£9,53011
In stock
+
PK2-2B-SS
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
0.02 to 2 bar (0.02 bar increments)
Pressure Unit:
bar
£10,14622
In stock
+
PK2-2B-SS/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
0.02 to 2 bar (0.02 bar increments)
Pressure Unit:
bar
£9,62899
In stock
+
PK2-20-SS-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 20 psi (1 psi increments)
Pressure Unit:
bar
£10,24511
In stock
+
PK2-20-SS-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 20 psi (1 psi increments)
Pressure Unit:
bar
£8,72383
In stock
+
PK2-20-SS-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 20 psi (1 psi increments)
Pressure Unit:
bar
£9,33580
In stock
+
PK2-20-SS-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 20 psi (1 psi increments)
Pressure Unit:
bar
£7,85601
In stock
+
PK2-20-SS
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 20 psi (1 psi increments)
Pressure Unit:
bar
£8,47213
In stock
+
PK2-20-SS/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 20 psi (1 psi increments)
Pressure Unit:
bar
£12,39495
In stock
+
PK2-201N-SS-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 200 kPa (0.5 kPa increments)
Pressure Unit:
bar
£13,01106
In stock
+
PK2-201N-SS-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 200 kPa (0.5 kPa increments)
Pressure Unit:
bar
£11,48979
In stock
+
PK2-201N-SS-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 200 kPa (0.5 kPa increments)
Pressure Unit:
bar
£12,10176
In stock
+
PK2-201N-SS-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 200 kPa (0.5 kPa increments)
Pressure Unit:
bar
£10,62197
In stock
+
PK2-201N-SS
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 200 kPa (0.5 kPa increments)
Pressure Unit:
bar
£11,23809
In stock
+
PK2-201N-SS/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 200 kPa (0.5 kPa increments)
Pressure Unit:
bar
£10,80798
In stock
+
PK2-30-SS-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 30 psi (1 psi increments)
Pressure Unit:
bar
£11,42410
In stock
+
PK2-30-SS-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 30 psi (1 psi increments)
Pressure Unit:
bar
£9,90282
In stock
+
PK2-30-SS-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 30 psi (1 psi increments)
Pressure Unit:
bar
£10,51479
In stock
+
PK2-30-SS-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 30 psi (1 psi increments)
Pressure Unit:
bar
£9,03500
In stock
+
PK2-30-SS
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
1 to 30 psi (1 psi increments)
Pressure Unit:
bar
£9,65112
In stock
+
PK2-30-SS/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
1 to 30 psi (1 psi increments)
Pressure Unit:
bar
£11,80649
In stock
+
PK2-1000CM-SS-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 1000 cmH2O (10 cmH2O increments)
Pressure Unit:
bar
£12,42261
In stock
+
PK2-1000CM-SS-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 1000 cmH2O (10 cmH2O increments)
Pressure Unit:
bar
£10,90133
In stock
+
PK2-1000CM-SS-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 1000 cmH2O (10 cmH2O increments)
Pressure Unit:
bar
£11,51330
In stock
+
PK2-1000CM-SS-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 1000 cmH2O (10 cmH2O increments)
Pressure Unit:
bar
£10,03351
In stock
+
PK2-1000CM-SS
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 1000 cmH2O (10 cmH2O increments)
Pressure Unit:
bar
£10,64963
In stock
+
PK2-1000CM-SS/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 1000 cmH2O (10 cmH2O increments)
Pressure Unit:
bar
£12,57335
In stock
+
PK2-1500CM-SS-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 1500 cmH2O (10 cmH2O increments)
Pressure Unit:
bar
£13,18947
In stock
+
PK2-1500CM-SS-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 1500 cmH2O (10 cmH2O increments)
Pressure Unit:
bar
£11,66819
In stock
+
PK2-1500CM-SS-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 1500 cmH2O (10 cmH2O increments)
Pressure Unit:
bar
£12,28016
In stock
+
PK2-1500CM-SS-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 1500 cmH2O (10 cmH2O increments)
Pressure Unit:
bar
£10,80037
In stock
+
PK2-1500CM-SS
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 1500 cmH2O (10 cmH2O increments)
Pressure Unit:
bar
£11,41649
In stock
+
PK2-1500CM-SS/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 1500 cmH2O (10 cmH2O increments)
Pressure Unit:
bar
£13,29803
In stock
+
PK2-2000CM-SS-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 2000 cmH2O (10 cmH2O increments)
Pressure Unit:
bar
£13,91415
In stock
+
PK2-2000CM-SS-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 2000 cmH2O (10 cmH2O increments)
Pressure Unit:
bar
£12,39287
In stock
+
PK2-2000CM-SS-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 2000 cmH2O (10 cmH2O increments)
Pressure Unit:
bar
£13,00484
In stock
+
PK2-2000CM-SS-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 2000 cmH2O (10 cmH2O increments)
Pressure Unit:
bar
£11,52505
In stock
+
PK2-2000CM-SS
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 2000 cmH2O (10 cmH2O increments)
Pressure Unit:
bar
£12,14117
In stock
+
PK2-2000CM-SS/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 2000 cmH2O (10 cmH2O increments)
Pressure Unit:
bar
£12,39495
In stock
+
PK2-2010GM-SS-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 2000 g/cm² (5 g/cm² increments)
Pressure Unit:
bar
£13,01106
In stock
+
PK2-2010GM-SS-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 2000 g/cm² (5 g/cm² increments)
Pressure Unit:
bar
£11,48979
In stock
+
PK2-2010GM-SS-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 2000 g/cm² (5 g/cm² increments)
Pressure Unit:
bar
£12,10176
In stock
+
PK2-2010GM-SS-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 2000 g/cm² (5 g/cm² increments)
Pressure Unit:
bar
£10,62197
In stock
+
PK2-2010GM-SS
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 2000 g/cm² (5 g/cm² increments)
Pressure Unit:
bar
£11,23809
In stock
+
PK2-2010GM-SS/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 2000 g/cm² (5 g/cm² increments)
Pressure Unit:
bar
£8,49356
In stock
+
PK2-250WC-SS-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 250 inH2O (10 inH2O increments)
Pressure Unit:
bar
£9,10968
In stock
+
PK2-250WC-SS-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 250 inH2O (10 inH2O increments)
Pressure Unit:
bar
£7,58840
In stock
+
PK2-250WC-SS-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 250 inH2O (10 inH2O increments)
Pressure Unit:
bar
£8,20037
In stock
+
PK2-250WC-SS-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 250 inH2O (10 inH2O increments)
Pressure Unit:
bar
£6,72059
In stock
+
PK2-250WC-SS
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 250 inH2O (10 inH2O increments)
Pressure Unit:
bar
£7,33670
In stock
+
PK2-250WC-SS/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 250 inH2O (10 inH2O increments)
Pressure Unit:
bar
£11,02372
In stock
+
PK2-500CM-SS-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 500 cmH2O (10 cmH2O increments)
Pressure Unit:
bar
£11,63984
In stock
+
PK2-500CM-SS-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 500 cmH2O (10 cmH2O increments)
Pressure Unit:
bar
£10,11856
In stock
+
PK2-500CM-SS-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 500 cmH2O (10 cmH2O increments)
Pressure Unit:
bar
£10,73053
In stock
+
PK2-500CM-SS-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 500 cmH2O (10 cmH2O increments)
Pressure Unit:
bar
£9,25074
In stock
+
PK2-500CM-SS
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 500 cmH2O (10 cmH2O increments)
Pressure Unit:
bar
£9,86686
In stock
+
PK2-500CM-SS/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 500 cmH2O (10 cmH2O increments)
Pressure Unit:
bar
£10,29282
In stock
+
PK2-650WC-SS-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 650 inH2O (10 inH2O increments)
Pressure Unit:
bar
£10,90894
In stock
+
PK2-650WC-SS-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 650 inH2O (10 inH2O increments)
Pressure Unit:
bar
£9,38766
In stock
+
PK2-650WC-SS-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 650 inH2O (10 inH2O increments)
Pressure Unit:
bar
£9,99963
In stock
+
PK2-650WC-SS-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 650 inH2O (10 inH2O increments)
Pressure Unit:
bar
£8,51984
In stock
+
PK2-650WC-SS
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 650 inH2O (10 inH2O increments)
Pressure Unit:
bar
£9,13596
In stock
+
PK2-650WC-SS/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 650 inH2O (10 inH2O increments)
Pressure Unit:
bar
£10,12133
In stock
+
PK2-700MB-SS-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 7000 mbar (20 mbar increments)
Pressure Unit:
bar
£10,73745
In stock
+
PK2-700MB-SS-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 7000 mbar (20 mbar increments)
Pressure Unit:
bar
£9,21617
In stock
+
PK2-700MB-SS-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 7000 mbar (20 mbar increments)
Pressure Unit:
bar
£9,82814
In stock
+
PK2-700MB-SS-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 7000 mbar (20 mbar increments)
Pressure Unit:
bar
£8,34835
In stock
+
PK2-700MB-SS
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 7000 mbar (20 mbar increments)
Pressure Unit:
bar
£8,96447
In stock
+
PK2-700MB-SS/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 7000 mbar (20 mbar increments)
Pressure Unit:
bar
£10,71947
In stock
+
PK2-850WC-SS-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 850 inH2O (10 inH2O increments)
Pressure Unit:
bar
£11,33559
In stock
+
PK2-850WC-SS-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 850 inH2O (10 inH2O increments)
Pressure Unit:
bar
£9,81431
In stock
+
PK2-850WC-SS-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 850 inH2O (10 inH2O increments)
Pressure Unit:
bar
£10,42628
In stock
+
PK2-850WC-SS-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 850 inH2O (10 inH2O increments)
Pressure Unit:
bar
£8,94649
In stock
+
PK2-850WC-SS
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
10 to 850 inH2O (10 inH2O increments)
Pressure Unit:
bar
£9,56261
In stock
+
PK2-850WC-SS/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
10 to 850 inH2O (10 inH2O increments)
Pressure Unit:
bar
£11,30309
In stock
+
PK2-200N-SS-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
2 to 200 kPa (2 kPa increments)
Pressure Unit:
bar
£11,91920
In stock
+
PK2-200N-SS-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
2 to 200 kPa (2 kPa increments)
Pressure Unit:
bar
£10,39793
In stock
+
PK2-200N-SS-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
2 to 200 kPa (2 kPa increments)
Pressure Unit:
bar
£11,00989
In stock
+
PK2-200N-SS-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
2 to 200 kPa (2 kPa increments)
Pressure Unit:
bar
£9,53011
In stock
+
PK2-200N-SS
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
2 to 200 kPa (2 kPa increments)
Pressure Unit:
bar
£10,14622
In stock
+
PK2-200N-SS/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
2 to 200 kPa (2 kPa increments)
Pressure Unit:
bar
£11,30309
In stock
+
PK2-2000GM-SS-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
25 to 2000 g/cm² (25 g/cm² increments)
Pressure Unit:
bar
£11,91920
In stock
+
PK2-2000GM-SS-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
25 to 2000 g/cm² (25 g/cm² increments)
Pressure Unit:
bar
£10,39793
In stock
+
PK2-2000GM-SS-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
25 to 2000 g/cm² (25 g/cm² increments)
Pressure Unit:
bar
£11,00989
In stock
+
PK2-2000GM-SS-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
25 to 2000 g/cm² (25 g/cm² increments)
Pressure Unit:
bar
£9,53011
In stock
+
PK2-2000GM-SS
Calibration:
±0.050% of reading; standard or local gravity; no calibration report
Pressure Range:
25 to 2000 g/cm² (25 g/cm² increments)
Pressure Unit:
bar
£10,14622
In stock
+
PK2-2000GM-SS/C
Calibration:
±0.050% of reading; standard or local gravity; with calibration report
Pressure Range:
25 to 2000 g/cm² (25 g/cm² increments)
Pressure Unit:
bar
£9,54463
In stock
+
PK2-304WC-SS-1A
Calibration:
±0.015% of reading; standard or local gravity; no calibration report
Pressure Range:
4 to 304 inH2O (1 inH2O increments)
Pressure Unit:
bar
£10,16074
In stock
+
PK2-304WC-SS-1A/C
Calibration:
±0.015% of reading; standard or local gravity; with calibration report
Pressure Range:
4 to 304 inH2O (1 inH2O increments)
Pressure Unit:
bar
£8,63947
In stock
+
PK2-304WC-SS-1B
Calibration:
±0.025% of reading; standard or local gravity; no calibration report
Pressure Range:
4 to 304 inH2O (1 inH2O increments)
Pressure Unit:
bar
£9,25144
In stock
+
PK2-304WC-SS-1B/C
Calibration:
±0.025% of reading; standard or local gravity; with calibration report
Pressure Range:
4 to 304 inH2O (1 inH2O increments)
Pressure Unit:
bar

Features

  • Pressure Range: 0.145 to 30 psi or equivalent
  • Available pressure units: psi, g/cm2, mbar, bar, kPa, inH2O, cmH2O
  • Accuracy: to ±0.05% of reading ( ±0.015 and 0.025% also available)
  • Repeatability: ±0.005% of reading
  • Local gravity calibration is available on all models
  • Floating Ball Operation
  • Self-Regulating
  • Interchangeable Weights
  • NIST Traceable

The floating ball Ametek PK II pneumatic deadweight tester is engineered to offer user-friendly features, safe operation, and an optimal performance in the field or in the lab.

The Ametek PK II pneumatic deadweight tester produces pressure by applying force (weight set) over area (the ceramic ball and nozzle). While in operation, the ball and weights float freely, supported only by a thin film of air which is virtually frictionless. This eliminates the necessity to rotate the weights during testing and allows the user to concentrate on the instrument calibration.

The Ametek PK II pneumatic deadweight tester is self-regulating with accuracy independent of the operator. The Ametek PK II pneumatic deadweight tester has a built-in flow regulator that automatically adjusts the input air flow to maintain the ball and weights in a float position. The regulator also compensates for variations in pressure from the air supply. These features of the Ametek PK II pneumatic deadweight tester eliminate the necessity of having to continually adjust the supply during the test and provides for an easy up and down scale calibration.

The setup for the Ametek PK II pneumatic deadweight tester is completed by simply connecting two tubes, one for the supply and one for the unit-under-test, leveling the PK II, and adding the appropriate weights. Operation is fast and efficient with no valves to adjust and no regulation needed between set points. Pressure regulators are not required if the air supply is within the Ametek PK II pneumatic deadweight tester's operational requirements.

The Ametek PK II pneumatic deadweight tester is NIST traceable and accurate to ±0.05% (optional accuracy up to ±0.015%) using stainless steel weights calibrated to International standard gravity at 9.80665 m/s2 or local gravity as specified. The Ametek PK II pneumatic deadweight tester's test fluid is nitrogen or instrument quality air complying with the ISA Standard S7.3. This fluid is non-contaminating to virtually all processes, thus eliminating the need to clean instruments after calibration and before use.

Ametek-PKII-Datasheet (Ametek-PKII-Datasheet.pdf, 181 Kb) [Download]

Ametek-PK-II-manual (Ametek-PK-II-manual.pdf, 975 Kb) [Download]

You may be interested
  • Most Popular
  • On Sale
  • Recently Viewed
 
Fast and high quality delivery

Our company makes delivery all over the country

Quality assurance and service

We offer only those goods, in which quality we are sure

Returns within 30 days

You have 30 days to test your purchase