VEGA VEGAMET 861 Controller Without, for Ex-free area (CE, UKCA, c-UL-us, RCM) With (certificate, as WHG conform limit alarm) M20x1.5 / 5x cable gland PA (ø6-12mm) For tube mounting (ø29-60mm), stainless steel

MET861.XXWSE
1,39445
In stock
+
Add to wish list
Delivery
Payment options
Our advantages
  • — 12 months warranty
  • — SMS notification
  • — Return and exchange
  • — Different payment methods
  • — Best price
Column filling
Sort by Price Sort by Availability Sort by CODE Sort by Explosion Protection Sort by Approved as Overfill Protection Sort by Cable Entry / Connection Sort by Mounting / Material
1,57422
In stock
+
MET861.VCW2E
Explosion Protection:
ATEX/c-UL-us; Installation Ex-free area; intrinsically safe supply, Class I Division 1, 2 + Class II,III Division 1, 2
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,52648
In stock
+
MET861.VCW2C
Explosion Protection:
ATEX/c-UL-us; Installation Ex-free area; intrinsically safe supply, Class I Division 1, 2 + Class II,III Division 1, 2
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For wall mounting, plastic
1,53156
In stock
+
MET861.VCWSE
Explosion Protection:
ATEX/c-UL-us; Installation Ex-free area; intrinsically safe supply, Class I Division 1, 2 + Class II,III Division 1, 2
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,48383
In stock
+
MET861.VCWSC
Explosion Protection:
ATEX/c-UL-us; Installation Ex-free area; intrinsically safe supply, Class I Division 1, 2 + Class II,III Division 1, 2
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For wall mounting, plastic
1,46961
In stock
+
MET861.VCW1E
Explosion Protection:
ATEX/c-UL-us; Installation Ex-free area; intrinsically safe supply, Class I Division 1, 2 + Class II,III Division 1, 2
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,42188
In stock
+
MET861.VCW1C
Explosion Protection:
ATEX/c-UL-us; Installation Ex-free area; intrinsically safe supply, Class I Division 1, 2 + Class II,III Division 1, 2
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For wall mounting, plastic
1,53156
In stock
+
MET861.VCX2E
Explosion Protection:
ATEX/c-UL-us; Installation Ex-free area; intrinsically safe supply, Class I Division 1, 2 + Class II,III Division 1, 2
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,48383
In stock
+
MET861.VCX2C
Explosion Protection:
ATEX/c-UL-us; Installation Ex-free area; intrinsically safe supply, Class I Division 1, 2 + Class II,III Division 1, 2
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For wall mounting, plastic
1,48891
In stock
+
MET861.VCXSE
Explosion Protection:
ATEX/c-UL-us; Installation Ex-free area; intrinsically safe supply, Class I Division 1, 2 + Class II,III Division 1, 2
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,44117
In stock
+
MET861.VCXSC
Explosion Protection:
ATEX/c-UL-us; Installation Ex-free area; intrinsically safe supply, Class I Division 1, 2 + Class II,III Division 1, 2
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For wall mounting, plastic
1,42695
In stock
+
MET861.VCX1E
Explosion Protection:
ATEX/c-UL-us; Installation Ex-free area; intrinsically safe supply, Class I Division 1, 2 + Class II,III Division 1, 2
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,37922
In stock
+
MET861.VCX1C
Explosion Protection:
ATEX/c-UL-us; Installation Ex-free area; intrinsically safe supply, Class I Division 1, 2 + Class II,III Division 1, 2
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For wall mounting, plastic
1,64328
In stock
+
MET861.VAW2E
Explosion Protection:
c-UL-us; Installation DIV2, gas; intrinsically safe supply, Zone 0, 1, 2 (Class I Division 1, 2) + Zone 20, 21, 22 (Clas
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,59555
In stock
+
MET861.VAW2C
Explosion Protection:
c-UL-us; Installation DIV2, gas; intrinsically safe supply, Zone 0, 1, 2 (Class I Division 1, 2) + Zone 20, 21, 22 (Clas
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For wall mounting, plastic
1,60063
In stock
+
MET861.VAWSE
Explosion Protection:
c-UL-us; Installation DIV2, gas; intrinsically safe supply, Zone 0, 1, 2 (Class I Division 1, 2) + Zone 20, 21, 22 (Clas
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,55289
In stock
+
MET861.VAWSC
Explosion Protection:
c-UL-us; Installation DIV2, gas; intrinsically safe supply, Zone 0, 1, 2 (Class I Division 1, 2) + Zone 20, 21, 22 (Clas
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For wall mounting, plastic
1,53867
In stock
+
MET861.VAW1E
Explosion Protection:
c-UL-us; Installation DIV2, gas; intrinsically safe supply, Zone 0, 1, 2 (Class I Division 1, 2) + Zone 20, 21, 22 (Clas
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,49094
In stock
+
MET861.VAW1C
Explosion Protection:
c-UL-us; Installation DIV2, gas; intrinsically safe supply, Zone 0, 1, 2 (Class I Division 1, 2) + Zone 20, 21, 22 (Clas
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For wall mounting, plastic
1,60063
In stock
+
MET861.VAX2E
Explosion Protection:
c-UL-us; Installation DIV2, gas; intrinsically safe supply, Zone 0, 1, 2 (Class I Division 1, 2) + Zone 20, 21, 22 (Clas
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,55289
In stock
+
MET861.VAX2C
Explosion Protection:
c-UL-us; Installation DIV2, gas; intrinsically safe supply, Zone 0, 1, 2 (Class I Division 1, 2) + Zone 20, 21, 22 (Clas
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For wall mounting, plastic
1,55797
In stock
+
MET861.VAXSE
Explosion Protection:
c-UL-us; Installation DIV2, gas; intrinsically safe supply, Zone 0, 1, 2 (Class I Division 1, 2) + Zone 20, 21, 22 (Clas
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,51023
In stock
+
MET861.VAXSC
Explosion Protection:
c-UL-us; Installation DIV2, gas; intrinsically safe supply, Zone 0, 1, 2 (Class I Division 1, 2) + Zone 20, 21, 22 (Clas
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For wall mounting, plastic
1,49602
In stock
+
MET861.VAX1E
Explosion Protection:
c-UL-us; Installation DIV2, gas; intrinsically safe supply, Zone 0, 1, 2 (Class I Division 1, 2) + Zone 20, 21, 22 (Clas
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,44828
In stock
+
MET861.VAX1C
Explosion Protection:
c-UL-us; Installation DIV2, gas; intrinsically safe supply, Zone 0, 1, 2 (Class I Division 1, 2) + Zone 20, 21, 22 (Clas
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For wall mounting, plastic
1,57422
In stock
+
MET861.TCW2E
Explosion Protection:
CCOE/KTL/TIIS/NEPSI; Installation Ex free area,intrinsically safe power supply, Zone 0, 1, 2 + Zone 20, 21, 22 not CCOE)
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,52648
In stock
+
MET861.TCW2C
Explosion Protection:
CCOE/KTL/TIIS/NEPSI; Installation Ex free area,intrinsically safe power supply, Zone 0, 1, 2 + Zone 20, 21, 22 not CCOE)
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For wall mounting, plastic
1,53156
In stock
+
MET861.TCWSE
Explosion Protection:
CCOE/KTL/TIIS/NEPSI; Installation Ex free area,intrinsically safe power supply, Zone 0, 1, 2 + Zone 20, 21, 22 not CCOE)
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,48383
In stock
+
MET861.TCWSC
Explosion Protection:
CCOE/KTL/TIIS/NEPSI; Installation Ex free area,intrinsically safe power supply, Zone 0, 1, 2 + Zone 20, 21, 22 not CCOE)
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For wall mounting, plastic
1,46961
In stock
+
MET861.TCW1E
Explosion Protection:
CCOE/KTL/TIIS/NEPSI; Installation Ex free area,intrinsically safe power supply, Zone 0, 1, 2 + Zone 20, 21, 22 not CCOE)
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,42188
In stock
+
MET861.TCW1C
Explosion Protection:
CCOE/KTL/TIIS/NEPSI; Installation Ex free area,intrinsically safe power supply, Zone 0, 1, 2 + Zone 20, 21, 22 not CCOE)
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For wall mounting, plastic
1,53156
In stock
+
MET861.TCX2E
Explosion Protection:
CCOE/KTL/TIIS/NEPSI; Installation Ex free area,intrinsically safe power supply, Zone 0, 1, 2 + Zone 20, 21, 22 not CCOE)
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,48383
In stock
+
MET861.TCX2C
Explosion Protection:
CCOE/KTL/TIIS/NEPSI; Installation Ex free area,intrinsically safe power supply, Zone 0, 1, 2 + Zone 20, 21, 22 not CCOE)
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For wall mounting, plastic
1,48891
In stock
+
MET861.TCXSE
Explosion Protection:
CCOE/KTL/TIIS/NEPSI; Installation Ex free area,intrinsically safe power supply, Zone 0, 1, 2 + Zone 20, 21, 22 not CCOE)
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,44117
In stock
+
MET861.TCXSC
Explosion Protection:
CCOE/KTL/TIIS/NEPSI; Installation Ex free area,intrinsically safe power supply, Zone 0, 1, 2 + Zone 20, 21, 22 not CCOE)
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For wall mounting, plastic
1,42695
In stock
+
MET861.TCX1E
Explosion Protection:
CCOE/KTL/TIIS/NEPSI; Installation Ex free area,intrinsically safe power supply, Zone 0, 1, 2 + Zone 20, 21, 22 not CCOE)
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,37922
In stock
+
MET861.TCX1C
Explosion Protection:
CCOE/KTL/TIIS/NEPSI; Installation Ex free area,intrinsically safe power supply, Zone 0, 1, 2 + Zone 20, 21, 22 not CCOE)
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For wall mounting, plastic
1,57422
In stock
+
MET861.WCW2E
Explosion Protection:
INMETRO/IA; installation Ex-free area; intrinsically safe supply, Zone 0, 1, 2 + Zone 20, 21, 22
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,52648
In stock
+
MET861.WCW2C
Explosion Protection:
INMETRO/IA; installation Ex-free area; intrinsically safe supply, Zone 0, 1, 2 + Zone 20, 21, 22
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For wall mounting, plastic
1,53156
In stock
+
MET861.WCWSE
Explosion Protection:
INMETRO/IA; installation Ex-free area; intrinsically safe supply, Zone 0, 1, 2 + Zone 20, 21, 22
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,48383
In stock
+
MET861.WCWSC
Explosion Protection:
INMETRO/IA; installation Ex-free area; intrinsically safe supply, Zone 0, 1, 2 + Zone 20, 21, 22
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For wall mounting, plastic
1,46961
In stock
+
MET861.WCW1E
Explosion Protection:
INMETRO/IA; installation Ex-free area; intrinsically safe supply, Zone 0, 1, 2 + Zone 20, 21, 22
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,42188
In stock
+
MET861.WCW1C
Explosion Protection:
INMETRO/IA; installation Ex-free area; intrinsically safe supply, Zone 0, 1, 2 + Zone 20, 21, 22
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For wall mounting, plastic
1,53156
In stock
+
MET861.WCX2E
Explosion Protection:
INMETRO/IA; installation Ex-free area; intrinsically safe supply, Zone 0, 1, 2 + Zone 20, 21, 22
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,48383
In stock
+
MET861.WCX2C
Explosion Protection:
INMETRO/IA; installation Ex-free area; intrinsically safe supply, Zone 0, 1, 2 + Zone 20, 21, 22
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For wall mounting, plastic
1,48891
In stock
+
MET861.WCXSE
Explosion Protection:
INMETRO/IA; installation Ex-free area; intrinsically safe supply, Zone 0, 1, 2 + Zone 20, 21, 22
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,44117
In stock
+
MET861.WCXSC
Explosion Protection:
INMETRO/IA; installation Ex-free area; intrinsically safe supply, Zone 0, 1, 2 + Zone 20, 21, 22
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For wall mounting, plastic
1,42695
In stock
+
MET861.WCX1E
Explosion Protection:
INMETRO/IA; installation Ex-free area; intrinsically safe supply, Zone 0, 1, 2 + Zone 20, 21, 22
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,37922
In stock
+
MET861.WCX1C
Explosion Protection:
INMETRO/IA; installation Ex-free area; intrinsically safe supply, Zone 0, 1, 2 + Zone 20, 21, 22
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For wall mounting, plastic
1,43711
In stock
+
MET861.XXW2E
Explosion Protection:
Without, for Ex-free area (CE, UKCA, c-UL-us, RCM)
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,38938
In stock
+
MET861.XXW2C
Explosion Protection:
Without, for Ex-free area (CE, UKCA, c-UL-us, RCM)
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For wall mounting, plastic
1,39445
In stock
+
MET861.XXWSE
Explosion Protection:
Without, for Ex-free area (CE, UKCA, c-UL-us, RCM)
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,34672
In stock
+
MET861.XXWSC
Explosion Protection:
Without, for Ex-free area (CE, UKCA, c-UL-us, RCM)
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For wall mounting, plastic
1,33250
In stock
+
MET861.XXW1E
Explosion Protection:
Without, for Ex-free area (CE, UKCA, c-UL-us, RCM)
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,28477
In stock
+
MET861.XXW1C
Explosion Protection:
Without, for Ex-free area (CE, UKCA, c-UL-us, RCM)
Approved as Overfill Protection:
With (certificate, as WHG conform limit alarm)
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For wall mounting, plastic
1,39445
In stock
+
MET861.XXX2E
Explosion Protection:
Without, for Ex-free area (CE, UKCA, c-UL-us, RCM)
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,34672
In stock
+
MET861.XXX2C
Explosion Protection:
Without, for Ex-free area (CE, UKCA, c-UL-us, RCM)
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x Adapter M20 / 1/2NPT, brass nickel plated
Mounting / Material:
For wall mounting, plastic
1,35180
In stock
+
MET861.XXXSE
Explosion Protection:
Without, for Ex-free area (CE, UKCA, c-UL-us, RCM)
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,30406
In stock
+
MET861.XXXSC
Explosion Protection:
Without, for Ex-free area (CE, UKCA, c-UL-us, RCM)
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / 5x cable gland PA (ø6-12mm)
Mounting / Material:
For wall mounting, plastic
1,28984
In stock
+
MET861.XXX1E
Explosion Protection:
Without, for Ex-free area (CE, UKCA, c-UL-us, RCM)
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For tube mounting (ø29-60mm), stainless steel
1,24211
In stock
+
MET861.XXX1C
Explosion Protection:
Without, for Ex-free area (CE, UKCA, c-UL-us, RCM)
Approved as Overfill Protection:
Without
Cable Entry / Connection:
M20x1.5 / without
Mounting / Material:
For wall mounting, plastic

Features

  • 4 to 20mA/HART sensor input
  • Type of input (selectable):
    • Active input sensor supply through VEGAMET 861
    • Passive input sensor has own voltage supply
  • Measured value transmission:
    • 4 to 20mA: analog for 4 to 20mA sensors
    • HART protocol: digital for HART sensors (not with passive input)
  • 0/4 to 20mA, 20 to 0/4mA current output
  • Relay output:
    • Four operating relays, one can be configured as fail safe relay
    • Switching voltage: max 250 V AC/60 V DC
    • Switching current: max 1 A AC (cos phi > 0.9), 1 A DC
  • ATEX / Europe, IEC / worldwide, UKEX approvals
  • IP66/IP67, Type 4X protection rating
  • Bluetooth 5.0
  • Simple and reliable commissioning and diagnosis of the measuring points via smartphone
  • Easy-to-read display from a distance, even in sunlight and darkness
  • Secure measurement data memory on SD card

The VEGA VEGAMET 861 controller feeds the connected 4 to 20mA or HART sensor, processes the measured values, and displays them. A large display for data visualization is integrated in the housing designed for rough field conditions.

The VEGAMET 861 enables a simple conversion of pump controls, flow measurements on open channels, and weirs, totalizers, and data loggers. The VEGAMET 861 allows limit values to be reliably monitored and relays to be switched, for example, for an overfill protection according to WHG.

VEGAMET-861-datasheet (VEGAMET-861-datasheet.pdf, 358 Kb) [Download]

VEGAMET-861-manual (VEGAMET-861-manual.pdf, 2,680 Kb) [Download]

You may be interested
  • Most Popular
  • On Sale
  • Recently Viewed
 
Fast and high quality delivery

Our company makes delivery all over the country

Quality assurance and service

We offer only those goods, in which quality we are sure

Returns within 30 days

You have 30 days to test your purchase