Isotech Fast-Cal Dry Block Calibrator -30°C to 140°C Standard Insert With 935-14-72/DB Semi-Standard Platinum Resistance Thermometer

FASTCAL LOW SITE
3,13106
In stock
+
Add to wish list
Delivery
Payment options
Our advantages
  • — 12 months warranty
  • — SMS notification
  • — Return and exchange
  • — Different payment methods
  • — Best price
Column filling
Sort by Price Sort by Availability Sort by CODE Sort by Temperature Range Sort by Insert Sort by Resistance Thermometer
81129
In stock
+
FASTCAL LOWHTM
Temperature Range:
-30°C to 140°C
Insert:
Insert Optimized for Hospital Validation Systems
Resistance Thermometer:
None
3,13106
In stock
+
FASTCAL LOWHTM SITE
Temperature Range:
-30°C to 140°C
Insert:
Insert Optimized for Hospital Validation Systems
Resistance Thermometer:
With 935-14-72/DB Semi-Standard Platinum Resistance Thermometer
2,20109
In stock
+
FASTCAL LOWHTM SITE
Temperature Range:
-30°C to 140°C
Insert:
Insert Optimized for Hospital Validation Systems
Resistance Thermometer:
With 935-14-82/DB Semi-Standard Platinum Resistance Thermometer
2,23533
In stock
+
FASTCAL LOWHTM SITE
Temperature Range:
-30°C to 140°C
Insert:
Insert Optimized for Hospital Validation Systems
Resistance Thermometer:
With 935-14-98/DB Semi-Standard Platinum Resistance Thermometer
81129
In stock
+
FASTCAL LOW
Temperature Range:
-30°C to 140°C
Insert:
Standard Insert
Resistance Thermometer:
None
3,13106
In stock
+
FASTCAL LOW SITE
Temperature Range:
-30°C to 140°C
Insert:
Standard Insert
Resistance Thermometer:
With 935-14-72/DB Semi-Standard Platinum Resistance Thermometer
2,20109
In stock
+
FASTCAL LOW SITE
Temperature Range:
-30°C to 140°C
Insert:
Standard Insert
Resistance Thermometer:
With 935-14-82/DB Semi-Standard Platinum Resistance Thermometer
2,23533
In stock
+
FASTCAL LOW SITE
Temperature Range:
-30°C to 140°C
Insert:
Standard Insert
Resistance Thermometer:
With 935-14-98/DB Semi-Standard Platinum Resistance Thermometer
Contact us for a price
In stock
FASTCAL MHTM
Temperature Range:
30°C to 350°C
Insert:
Insert Optimized for Hospital Validation Systems
Resistance Thermometer:
None
2,31977
In stock
+
FASTCAL MHTM SITE
Temperature Range:
30°C to 350°C
Insert:
Insert Optimized for Hospital Validation Systems
Resistance Thermometer:
With 935-14-72/DB Semi-Standard Platinum Resistance Thermometer
1,38980
In stock
+
FASTCAL MHTM SITE
Temperature Range:
30°C to 350°C
Insert:
Insert Optimized for Hospital Validation Systems
Resistance Thermometer:
With 935-14-82/DB Semi-Standard Platinum Resistance Thermometer
1,42404
In stock
+
FASTCAL MHTM SITE
Temperature Range:
30°C to 350°C
Insert:
Insert Optimized for Hospital Validation Systems
Resistance Thermometer:
With 935-14-98/DB Semi-Standard Platinum Resistance Thermometer
Contact us for a price
In stock
FASTCAL M
Temperature Range:
30°C to 350°C
Insert:
Standard Insert
Resistance Thermometer:
None
2,31977
In stock
+
FASTCAL M SITE
Temperature Range:
30°C to 350°C
Insert:
Standard Insert
Resistance Thermometer:
With 935-14-72/DB Semi-Standard Platinum Resistance Thermometer
1,38980
In stock
+
FASTCAL M SITE
Temperature Range:
30°C to 350°C
Insert:
Standard Insert
Resistance Thermometer:
With 935-14-82/DB Semi-Standard Platinum Resistance Thermometer
1,42404
In stock
+
FASTCAL M SITE
Temperature Range:
30°C to 350°C
Insert:
Standard Insert
Resistance Thermometer:
With 935-14-98/DB Semi-Standard Platinum Resistance Thermometer
81129
In stock
+
FASTCAL HIGHHTM
Temperature Range:
35°C to 650°C
Insert:
Insert Optimized for Hospital Validation Systems
Resistance Thermometer:
None
3,13106
In stock
+
FASTCAL HIGHHTM SITE
Temperature Range:
35°C to 650°C
Insert:
Insert Optimized for Hospital Validation Systems
Resistance Thermometer:
With 935-14-72/DB Semi-Standard Platinum Resistance Thermometer
2,20109
In stock
+
FASTCAL HIGHHTM SITE
Temperature Range:
35°C to 650°C
Insert:
Insert Optimized for Hospital Validation Systems
Resistance Thermometer:
With 935-14-82/DB Semi-Standard Platinum Resistance Thermometer
2,23533
In stock
+
FASTCAL HIGHHTM SITE
Temperature Range:
35°C to 650°C
Insert:
Insert Optimized for Hospital Validation Systems
Resistance Thermometer:
With 935-14-98/DB Semi-Standard Platinum Resistance Thermometer
81129
In stock
+
FASTCAL HIGH
Temperature Range:
35°C to 650°C
Insert:
Standard Insert
Resistance Thermometer:
None
3,13106
In stock
+
FASTCAL HIGH SITE
Temperature Range:
35°C to 650°C
Insert:
Standard Insert
Resistance Thermometer:
With 935-14-72/DB Semi-Standard Platinum Resistance Thermometer
2,20109
In stock
+
FASTCAL HIGH SITE
Temperature Range:
35°C to 650°C
Insert:
Standard Insert
Resistance Thermometer:
With 935-14-82/DB Semi-Standard Platinum Resistance Thermometer
2,23533
In stock
+
FASTCAL HIGH SITE
Temperature Range:
35°C to 650°C
Insert:
Standard Insert
Resistance Thermometer:
With 935-14-98/DB Semi-Standard Platinum Resistance Thermometer

Features

  • Low Temperature (-35 to +140°C)
    • Stability: 0.02°C
    • Accuracy: ±0.2°C (basic); ±0.15°C (complete)
    • Heating/Cooling Time: 15 minutes
    • Power: 150W
  • Medium Temperature (-30 to +350°C)
    • Stability: 0.03°C
    • Accuracy: ±0.3°C (basic); ±0.2°C (complete)
    • Heating Time: 15 minutes
    • Cooling Time: 40 minutes
    • Power: 750W
  • High Temperature (35 to +650°C)
    • Stability: 0.05°C
    • Accuracy: 1°C±0.5°C (basic); ±0.5°C (complete)
    • Heating/Cooling Time: 20 minutes
    • Power: 750W
  • Calibration Capacity: 148mm depth; 25 mm diameter

The Isotech Fast-Cal dry block calibrator is a rugged, lightweight, easy-to-use calibrator with stainless steel housing. The hygienic housing of the Fast-Cal does not have paint, eliminating the chance of chipping or flaking. A soft, lightweight shoulder case is included to make transporting the Fast-Cal nearly effortless. Two inserts are available for the Fast-Cal, a standard insert and an insert that is optimized for hospital validation systems.

The block gradients of the Isotech Fast-Cal dry block calibrator are minimized by non-linear heating and cooling profiles to compensate for end losses to ambient temperature. Three temperature ranges are available: -35 to +140°C (low), -30 to +350°C (medium) and 35 to +650°C (high). The low range features a stability of 0.02°C, with a complete accuracy of ±0.15°C. The medium temperature range has 0.03°C stability with ±0.2°C complete accuracy. With a stability of 0.05°C, the high range model offers ±0.5°C accuracy.

CalNotePad software is included standard with the Isotech Fast-Cal dry block calibrator. This allows you to connect both an indicator and the calibration bath to a PC. You can view data on clear, configurable chart displays, log data to a file and control the calibration bath. I-Cal software (optional accessory) is also compatible with the Fast-Cal and can automatically calibrate up to 16 temperature sensors.

Fast-Cal-datasheet (Fast-Cal-datasheet.pdf, 313 Kb) [Download]