Rosemount Analytical Model T1056 Clarity II Turbidimeter Two ISO Sensors 20 ft (6.1m) Single input No

T1056-41-60-20-30
1,82305
In stock
+
Add to wish list
Delivery
Payment options
Our advantages
  • — 12 months warranty
  • — SMS notification
  • — Return and exchange
  • — Different payment methods
  • — Best price
Column filling
Sort by Price Sort by Availability Sort by CODE Sort by Sensor Sort by Sensor Cable Sort by Instrument Sort by Calibration Cup
55352
In stock
+
T1056-02-10-23-31
Sensor:
ISO Sensor
Sensor Cable:
(1) 20 ft. (6.1m) cable and (1) 50 ft. (15.2m) cable
Instrument:
Dual input
Calibration Cup:
No
1,29898
In stock
+
T1056-02-10-23-33
Sensor:
ISO Sensor
Sensor Cable:
(1) 20 ft. (6.1m) cable and (1) 50 ft. (15.2m) cable
Instrument:
Dual input with HART ® communications
Calibration Cup:
No
1,44930
In stock
+
T1056-02-10-23-33-71
Sensor:
ISO Sensor
Sensor Cable:
(1) 20 ft. (6.1m) cable and (1) 50 ft. (15.2m) cable
Instrument:
Dual input with HART ® communications
Calibration Cup:
Yes (Recommended)
70383
In stock
+
T1056-02-10-23-31-71
Sensor:
ISO Sensor
Sensor Cable:
(1) 20 ft. (6.1m) cable and (1) 50 ft. (15.2m) cable
Instrument:
Dual input
Calibration Cup:
Yes (Recommended)
24781
In stock
+
T1056-02-10-23-30
Sensor:
ISO Sensor
Sensor Cable:
(1) 20 ft. (6.1m) cable and (1) 50 ft. (15.2m) cable
Instrument:
Single input
Calibration Cup:
No
99328
In stock
+
T1056-02-10-23-32
Sensor:
ISO Sensor
Sensor Cable:
(1) 20 ft. (6.1m) cable and (1) 50 ft. (15.2m) cable
Instrument:
Single input with HART® communications
Calibration Cup:
No
1,14359
In stock
+
T1056-02-10-23-32-71
Sensor:
ISO Sensor
Sensor Cable:
(1) 20 ft. (6.1m) cable and (1) 50 ft. (15.2m) cable
Instrument:
Single input with HART® communications
Calibration Cup:
Yes (Recommended)
39813
In stock
+
T1056-02-10-23-30-71
Sensor:
ISO Sensor
Sensor Cable:
(1) 20 ft. (6.1m) cable and (1) 50 ft. (15.2m) cable
Instrument:
Single input
Calibration Cup:
Yes (Recommended)
30570
In stock
+
T1056-02-10-50-31
Sensor:
ISO Sensor
Sensor Cable:
(2) 20 ft. (6.1 m) cables
Instrument:
Dual input
Calibration Cup:
No
1,05117
In stock
+
T1056-02-10-50-33
Sensor:
ISO Sensor
Sensor Cable:
(2) 20 ft. (6.1 m) cables
Instrument:
Dual input with HART ® communications
Calibration Cup:
No
1,20148
In stock
+
T1056-02-10-50-33-71
Sensor:
ISO Sensor
Sensor Cable:
(2) 20 ft. (6.1 m) cables
Instrument:
Dual input with HART ® communications
Calibration Cup:
Yes (Recommended)
45602
In stock
+
T1056-02-10-50-31-71
Sensor:
ISO Sensor
Sensor Cable:
(2) 20 ft. (6.1 m) cables
Instrument:
Dual input
Calibration Cup:
Yes (Recommended)
Contact us for a price
In stock
T1056-02-10-50-30
Sensor:
ISO Sensor
Sensor Cable:
(2) 20 ft. (6.1 m) cables
Instrument:
Single input
Calibration Cup:
No
74547
In stock
+
T1056-02-10-50-32
Sensor:
ISO Sensor
Sensor Cable:
(2) 20 ft. (6.1 m) cables
Instrument:
Single input with HART® communications
Calibration Cup:
No
89578
In stock
+
T1056-02-10-50-32-71
Sensor:
ISO Sensor
Sensor Cable:
(2) 20 ft. (6.1 m) cables
Instrument:
Single input with HART® communications
Calibration Cup:
Yes (Recommended)
15031
In stock
+
T1056-02-10-50-30-71
Sensor:
ISO Sensor
Sensor Cable:
(2) 20 ft. (6.1 m) cables
Instrument:
Single input
Calibration Cup:
Yes (Recommended)
80234
In stock
+
T1056-02-10-51-31
Sensor:
ISO Sensor
Sensor Cable:
(2) 50 ft. (15.2m) cables
Instrument:
Dual input
Calibration Cup:
No
1,54781
In stock
+
T1056-02-10-51-33
Sensor:
ISO Sensor
Sensor Cable:
(2) 50 ft. (15.2m) cables
Instrument:
Dual input with HART ® communications
Calibration Cup:
No
1,69813
In stock
+
T1056-02-10-51-33-71
Sensor:
ISO Sensor
Sensor Cable:
(2) 50 ft. (15.2m) cables
Instrument:
Dual input with HART ® communications
Calibration Cup:
Yes (Recommended)
95266
In stock
+
T1056-02-10-51-31-71
Sensor:
ISO Sensor
Sensor Cable:
(2) 50 ft. (15.2m) cables
Instrument:
Dual input
Calibration Cup:
Yes (Recommended)
49664
In stock
+
T1056-02-10-51-30
Sensor:
ISO Sensor
Sensor Cable:
(2) 50 ft. (15.2m) cables
Instrument:
Single input
Calibration Cup:
No
1,24211
In stock
+
T1056-02-10-51-32
Sensor:
ISO Sensor
Sensor Cable:
(2) 50 ft. (15.2m) cables
Instrument:
Single input with HART® communications
Calibration Cup:
No
1,39242
In stock
+
T1056-02-10-51-32-71
Sensor:
ISO Sensor
Sensor Cable:
(2) 50 ft. (15.2m) cables
Instrument:
Single input with HART® communications
Calibration Cup:
Yes (Recommended)
64695
In stock
+
T1056-02-10-51-30-71
Sensor:
ISO Sensor
Sensor Cable:
(2) 50 ft. (15.2m) cables
Instrument:
Single input
Calibration Cup:
Yes (Recommended)
30570
In stock
+
T1056-02-10-20-31
Sensor:
ISO Sensor
Sensor Cable:
20 ft (6.1m)
Instrument:
Dual input
Calibration Cup:
No
1,05117
In stock
+
T1056-02-10-20-33
Sensor:
ISO Sensor
Sensor Cable:
20 ft (6.1m)
Instrument:
Dual input with HART ® communications
Calibration Cup:
No
1,20148
In stock
+
T1056-02-10-20-33-71
Sensor:
ISO Sensor
Sensor Cable:
20 ft (6.1m)
Instrument:
Dual input with HART ® communications
Calibration Cup:
Yes (Recommended)
45602
In stock
+
T1056-02-10-20-31-71
Sensor:
ISO Sensor
Sensor Cable:
20 ft (6.1m)
Instrument:
Dual input
Calibration Cup:
Yes (Recommended)
Contact us for a price
In stock
T1056-02-10-20-30
Sensor:
ISO Sensor
Sensor Cable:
20 ft (6.1m)
Instrument:
Single input
Calibration Cup:
No
74547
In stock
+
T1056-02-10-20-32
Sensor:
ISO Sensor
Sensor Cable:
20 ft (6.1m)
Instrument:
Single input with HART® communications
Calibration Cup:
No
89578
In stock
+
T1056-02-10-20-32-71
Sensor:
ISO Sensor
Sensor Cable:
20 ft (6.1m)
Instrument:
Single input with HART® communications
Calibration Cup:
Yes (Recommended)
15031
In stock
+
T1056-02-10-20-30-71
Sensor:
ISO Sensor
Sensor Cable:
20 ft (6.1m)
Instrument:
Single input
Calibration Cup:
Yes (Recommended)
55352
In stock
+
T1056-02-10-21-31
Sensor:
ISO Sensor
Sensor Cable:
50 ft. (15.2 m)
Instrument:
Dual input
Calibration Cup:
No
1,29898
In stock
+
T1056-02-10-21-33
Sensor:
ISO Sensor
Sensor Cable:
50 ft. (15.2 m)
Instrument:
Dual input with HART ® communications
Calibration Cup:
No
1,44930
In stock
+
T1056-02-10-21-33-71
Sensor:
ISO Sensor
Sensor Cable:
50 ft. (15.2 m)
Instrument:
Dual input with HART ® communications
Calibration Cup:
Yes (Recommended)
70383
In stock
+
T1056-02-10-21-31-71
Sensor:
ISO Sensor
Sensor Cable:
50 ft. (15.2 m)
Instrument:
Dual input
Calibration Cup:
Yes (Recommended)
24781
In stock
+
T1056-02-10-21-30
Sensor:
ISO Sensor
Sensor Cable:
50 ft. (15.2 m)
Instrument:
Single input
Calibration Cup:
No
99328
In stock
+
T1056-02-10-21-32
Sensor:
ISO Sensor
Sensor Cable:
50 ft. (15.2 m)
Instrument:
Single input with HART® communications
Calibration Cup:
No
1,14359
In stock
+
T1056-02-10-21-32-71
Sensor:
ISO Sensor
Sensor Cable:
50 ft. (15.2 m)
Instrument:
Single input with HART® communications
Calibration Cup:
Yes (Recommended)
39813
In stock
+
T1056-02-10-21-30-71
Sensor:
ISO Sensor
Sensor Cable:
50 ft. (15.2 m)
Instrument:
Single input
Calibration Cup:
Yes (Recommended)
2,37656
In stock
+
T1056-41-60-23-31
Sensor:
Two ISO Sensors
Sensor Cable:
(1) 20 ft. (6.1m) cable and (1) 50 ft. (15.2m) cable
Instrument:
Dual input
Calibration Cup:
No
3,12203
In stock
+
T1056-41-60-23-33
Sensor:
Two ISO Sensors
Sensor Cable:
(1) 20 ft. (6.1m) cable and (1) 50 ft. (15.2m) cable
Instrument:
Dual input with HART ® communications
Calibration Cup:
No
3,27234
In stock
+
T1056-41-60-23-33-71
Sensor:
Two ISO Sensors
Sensor Cable:
(1) 20 ft. (6.1m) cable and (1) 50 ft. (15.2m) cable
Instrument:
Dual input with HART ® communications
Calibration Cup:
Yes (Recommended)
2,52688
In stock
+
T1056-41-60-23-31-71
Sensor:
Two ISO Sensors
Sensor Cable:
(1) 20 ft. (6.1m) cable and (1) 50 ft. (15.2m) cable
Instrument:
Dual input
Calibration Cup:
Yes (Recommended)
2,07086
In stock
+
T1056-41-60-23-30
Sensor:
Two ISO Sensors
Sensor Cable:
(1) 20 ft. (6.1m) cable and (1) 50 ft. (15.2m) cable
Instrument:
Single input
Calibration Cup:
No
2,81633
In stock
+
T1056-41-60-23-32
Sensor:
Two ISO Sensors
Sensor Cable:
(1) 20 ft. (6.1m) cable and (1) 50 ft. (15.2m) cable
Instrument:
Single input with HART® communications
Calibration Cup:
No
2,96664
In stock
+
T1056-41-60-23-32-71
Sensor:
Two ISO Sensors
Sensor Cable:
(1) 20 ft. (6.1m) cable and (1) 50 ft. (15.2m) cable
Instrument:
Single input with HART® communications
Calibration Cup:
Yes (Recommended)
2,22117
In stock
+
T1056-41-60-23-30-71
Sensor:
Two ISO Sensors
Sensor Cable:
(1) 20 ft. (6.1m) cable and (1) 50 ft. (15.2m) cable
Instrument:
Single input
Calibration Cup:
Yes (Recommended)
2,12875
In stock
+
T1056-41-60-50-31
Sensor:
Two ISO Sensors
Sensor Cable:
(2) 20 ft. (6.1 m) cables
Instrument:
Dual input
Calibration Cup:
No
2,87422
In stock
+
T1056-41-60-50-33
Sensor:
Two ISO Sensors
Sensor Cable:
(2) 20 ft. (6.1 m) cables
Instrument:
Dual input with HART ® communications
Calibration Cup:
No
3,02453
In stock
+
T1056-41-60-50-33-71
Sensor:
Two ISO Sensors
Sensor Cable:
(2) 20 ft. (6.1 m) cables
Instrument:
Dual input with HART ® communications
Calibration Cup:
Yes (Recommended)
2,27906
In stock
+
T1056-41-60-50-31-71
Sensor:
Two ISO Sensors
Sensor Cable:
(2) 20 ft. (6.1 m) cables
Instrument:
Dual input
Calibration Cup:
Yes (Recommended)
1,82305
In stock
+
T1056-41-60-50-30
Sensor:
Two ISO Sensors
Sensor Cable:
(2) 20 ft. (6.1 m) cables
Instrument:
Single input
Calibration Cup:
No
2,56852
In stock
+
T1056-41-60-50-32
Sensor:
Two ISO Sensors
Sensor Cable:
(2) 20 ft. (6.1 m) cables
Instrument:
Single input with HART® communications
Calibration Cup:
No
2,71883
In stock
+
T1056-41-60-50-32-71
Sensor:
Two ISO Sensors
Sensor Cable:
(2) 20 ft. (6.1 m) cables
Instrument:
Single input with HART® communications
Calibration Cup:
Yes (Recommended)
1,97336
In stock
+
T1056-41-60-50-30-71
Sensor:
Two ISO Sensors
Sensor Cable:
(2) 20 ft. (6.1 m) cables
Instrument:
Single input
Calibration Cup:
Yes (Recommended)
2,62539
In stock
+
T1056-41-60-51-31
Sensor:
Two ISO Sensors
Sensor Cable:
(2) 50 ft. (15.2m) cables
Instrument:
Dual input
Calibration Cup:
No
3,37086
In stock
+
T1056-41-60-51-33
Sensor:
Two ISO Sensors
Sensor Cable:
(2) 50 ft. (15.2m) cables
Instrument:
Dual input with HART ® communications
Calibration Cup:
No
3,52117
In stock
+
T1056-41-60-51-33-71
Sensor:
Two ISO Sensors
Sensor Cable:
(2) 50 ft. (15.2m) cables
Instrument:
Dual input with HART ® communications
Calibration Cup:
Yes (Recommended)
2,77570
In stock
+
T1056-41-60-51-31-71
Sensor:
Two ISO Sensors
Sensor Cable:
(2) 50 ft. (15.2m) cables
Instrument:
Dual input
Calibration Cup:
Yes (Recommended)
2,31969
In stock
+
T1056-41-60-51-30
Sensor:
Two ISO Sensors
Sensor Cable:
(2) 50 ft. (15.2m) cables
Instrument:
Single input
Calibration Cup:
No
3,06516
In stock
+
T1056-41-60-51-32
Sensor:
Two ISO Sensors
Sensor Cable:
(2) 50 ft. (15.2m) cables
Instrument:
Single input with HART® communications
Calibration Cup:
No
3,21547
In stock
+
T1056-41-60-51-32-71
Sensor:
Two ISO Sensors
Sensor Cable:
(2) 50 ft. (15.2m) cables
Instrument:
Single input with HART® communications
Calibration Cup:
Yes (Recommended)
2,47000
In stock
+
T1056-41-60-51-30-71
Sensor:
Two ISO Sensors
Sensor Cable:
(2) 50 ft. (15.2m) cables
Instrument:
Single input
Calibration Cup:
Yes (Recommended)
2,12875
In stock
+
T1056-41-60-20-31
Sensor:
Two ISO Sensors
Sensor Cable:
20 ft (6.1m)
Instrument:
Dual input
Calibration Cup:
No
2,87422
In stock
+
T1056-41-60-20-33
Sensor:
Two ISO Sensors
Sensor Cable:
20 ft (6.1m)
Instrument:
Dual input with HART ® communications
Calibration Cup:
No
3,02453
In stock
+
T1056-41-60-20-33-71
Sensor:
Two ISO Sensors
Sensor Cable:
20 ft (6.1m)
Instrument:
Dual input with HART ® communications
Calibration Cup:
Yes (Recommended)
2,27906
In stock
+
T1056-41-60-20-31-71
Sensor:
Two ISO Sensors
Sensor Cable:
20 ft (6.1m)
Instrument:
Dual input
Calibration Cup:
Yes (Recommended)
1,82305
In stock
+
T1056-41-60-20-30
Sensor:
Two ISO Sensors
Sensor Cable:
20 ft (6.1m)
Instrument:
Single input
Calibration Cup:
No
2,56852
In stock
+
T1056-41-60-20-32
Sensor:
Two ISO Sensors
Sensor Cable:
20 ft (6.1m)
Instrument:
Single input with HART® communications
Calibration Cup:
No
2,71883
In stock
+
T1056-41-60-20-32-71
Sensor:
Two ISO Sensors
Sensor Cable:
20 ft (6.1m)
Instrument:
Single input with HART® communications
Calibration Cup:
Yes (Recommended)
1,97336
In stock
+
T1056-41-60-20-30-71
Sensor:
Two ISO Sensors
Sensor Cable:
20 ft (6.1m)
Instrument:
Single input
Calibration Cup:
Yes (Recommended)
2,37656
In stock
+
T1056-41-60-21-31
Sensor:
Two ISO Sensors
Sensor Cable:
50 ft. (15.2 m)
Instrument:
Dual input
Calibration Cup:
No
3,12203
In stock
+
T1056-41-60-21-33
Sensor:
Two ISO Sensors
Sensor Cable:
50 ft. (15.2 m)
Instrument:
Dual input with HART ® communications
Calibration Cup:
No
3,27234
In stock
+
T1056-41-60-21-33-71
Sensor:
Two ISO Sensors
Sensor Cable:
50 ft. (15.2 m)
Instrument:
Dual input with HART ® communications
Calibration Cup:
Yes (Recommended)
2,52688
In stock
+
T1056-41-60-21-31-71
Sensor:
Two ISO Sensors
Sensor Cable:
50 ft. (15.2 m)
Instrument:
Dual input
Calibration Cup:
Yes (Recommended)
2,07086
In stock
+
T1056-41-60-21-30
Sensor:
Two ISO Sensors
Sensor Cable:
50 ft. (15.2 m)
Instrument:
Single input
Calibration Cup:
No
2,81633
In stock
+
T1056-41-60-21-32
Sensor:
Two ISO Sensors
Sensor Cable:
50 ft. (15.2 m)
Instrument:
Single input with HART® communications
Calibration Cup:
No
2,96664
In stock
+
T1056-41-60-21-32-71
Sensor:
Two ISO Sensors
Sensor Cable:
50 ft. (15.2 m)
Instrument:
Single input with HART® communications
Calibration Cup:
Yes (Recommended)
2,22117
In stock
+
T1056-41-60-21-30-71
Sensor:
Two ISO Sensors
Sensor Cable:
50 ft. (15.2 m)
Instrument:
Single input
Calibration Cup:
Yes (Recommended)

Features

  • Complete system includes single or dual input analyzer, sensor(s) and debubbler assembly
  • ISO Method 7027 compliant sensors
  • 0-20 NTU range (contact us for ranges above 20 NTU)
  • 0.001 NTU resolution
  • HART Digital Communications available
  • 4 alarm relays

The Rosemount Analytical Model T1056 Clarity II Turbidimeter is intended for the determination of turbidity in water. Low stray light, high stability, efficient bubble rejection, and a display resolution of 0.001 NTU make Rosemount Analytical Model T1056 Clarity II ideal for monitoring the turbidity of filtered drinking water. Clarity II is also suitable for applications other than drinking water treatment including monitoring of filtered water discharges, condensate returns and clarifiers. Please contact us for any applications other than drinking water to ensure product suitability.

The Rosemount Analytical Model T1056 Clarity II Turbidimeter consists of an analyzer, which accepts either one or two signal input boards, sensors, and a debubbler / measuring chamber and cable for each sensor. The cable plugs into the sensor and the analyzer, making setup fast and easy. Sensors can be located as far as 50 ft (15.2m) away from the Rosemount Analytical Model T1056 Clarity II analyzer.

The Rosemount Analytical Clarity II incorporates the easy-to-use Model 1056 intelligent analyzer. The 4-20 mA analog outputs are fully scalable. Every unit includes four alarm relays with interval timer functions. Alarms are fully programmable for high/low logic and dead band.

A calibration cup is included in the purchase price.

T1056_ClarityII-datasheet (T1056_ClarityII-datasheet.pdf, 234 Kb) [Download]

Rosemount-T1056_manual (Rosemount-T1056_manual.pdf, 2,108 Kb) [Download]